AVAlessandro Vichi

Alessandro Vichi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alessandro Vichi has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Influência da Cor do Pilar e da Espessura da Mucosa Sobre a Cor do Tecido Mole

    by Marco Ferrari, Michele Carrabba, Alessandro Vichi, Cecilia Goracci, Maria Crysanti Cagidiaco

    • 1 August 2015
      • Vol. 28  (4) , 235-40

    Short-term clinical performance of zirconia single crowns with different framework designs: 3-year clinical trial.

    by Marco Ferrari, Roberto Sorrentino, Crysanti Cagidiaco, Cecilia Goracci, Alessandro Vichi, Enrico Gherlone, Fernando Zarone

    The present prospective clinical study evaluated the influence of coping design on the fracture resistance of CAD/CAM zirconia single crowns layered with dedicated ceramics. 56 subjects were provided with 90 zirconia single crowns in posterior regions. Tooth preparations were standardized and the abutment teeth were randomly distributed into three groups, according to three different coping designs (flat design, FD; porcelain-fused-to-metal-like crowns, PFM; anatomically-guided, AG). The zirconia cores were produced using a CAD/CAM software and then were hand-layered with dedicated ceramics. All crowns were cemented with a self-adhesive resin luting agent and the patients were recalled for follow-up visits after 1 month, 6 months, 1, 2 and 3 years of clinical service. The function, esthetics and marginal adaptation of the restorations were evaluated. Statistical analyses were performed to evaluate survival and success of the restorations. Success rates of 100% were reported in Group 2 and Group 3 while the percentage was 80% in Group 1. Three chippings were noticed in Group 1 (FD) and two crowns needed to be replaced after 3 years, resulting in a survival rate of 93.3%. Group 2 and Group 3 had significantly higher 3-year success rates than Group 1 (P < 0.05). Based on the present clinical results, the following conclusions were drawn: the porcelain-fused-to-metal-like and the anatomically-guided frameworks for zirconia single crowns performed better clinically than the flat designed cores in posterior regions after 3 years; standardized tooth preparations achieved even thicknesses of the bilayered restorations; the proper support given to the veneering ceramic by the correct design of the zirconia framework could significantly reduce the risk of chipping during function.


  • Influence of luting agent translucency on fiber post retention

    by Jelena Juloski, Cecilia Goracci, Nino Tsintsadze, Michele Carrabba, Alessandro Vichi, Zoran R. Vulicevic, Marco Ferrari


    • 1 February 2014
      • Vol. 27  (1) , 17-22

    Flexural resistance of Cerec CAD/CAM system ceramic blocks. Part 2: Outsourcing materials.

    by Maurizio Sedda, Alessandro Vichi, Francesco Del Siena, Chris Louca, Marco Ferrari

    To test different Cerec CAD/CAM system ceramic blocks, comparing mean flexural strength (sigma), Weibull modulus (m), and Weibull characteristic strength (sigma0) in an ISO standardized set-up. Following the recent ISO Standard (ISO 6872:2008), 11 types of ceramic blocks were tested: IPS e.max CAD MO, IPS e.max CAD LT and IPS e.max CAD HT (lithium disilicate glass-ceramic); In-Ceram SPINELL, In-Ceram Alumina and In-Ceram Zirconia (glass-infiltrated materials); inCoris AL and In-Ceram AL (densely sintered alumina); In-Ceram YZ, IPS e.max Zir-CAD and inCoris ZI (densely sintered zirconia). Specimens were cut out from ceramic blocks, finished, crystallized/infiltrated/sintered, polished, and tested in a three-point bending test apparatus. Flexural strength, Weibull characteristic strength, and Weibull modulus were obtained. A statistically significant difference was found (P < 0.001) among lithium disilicate glass-ceramic (sigma = 272.6 +/- 376.8 MPa, m = 6.2 +/- 11.3, sigma0 = 294.0 +/- 394.1 MPa) and densely sintered alumina (sigma = 441.8 +/- 541.6 MPa, m = 11.9 +/- 19.0, sigma0 = 454.2 +/- 565.2 MPa). No statistically significant difference was found (P = 0.254) in glass infiltrated materials (sigma = 376.9 +/- 405.5 MPa, m = 7.5 +/- 11.5, sigma0 = 393.7 +/- 427.0 MPa). No statistically significant difference was found (P = 0.160) in densely sintered zirconia (sigma = 1,060.8 +/- 1,227.8 MPa, m = 5.8 +/- 7.4, sigma0 = 1,002.4 +/- 1,171.0 MPa). Not all the materials tested fulfilled the requirements for the clinical indications recommended by the manufacturer.


    • 1 December 2013
      • Vol. 26  (6) , 324-8

    Post-retentive ability of new flowable resin composites.

    by Jelena Juloski, Cecilia Goracci, Ivana Radovic, Nicoletta Chieffi, Alessandro Vichi, Zoran R Vulicevic, Marco Ferrari

    To investigate the applicability of flowable composites as post luting agents by assessing the push-out strength of posts. 36 intact single rooted human premolars were selected. The endodontic treatment was performed and half of the specimens were restored with light transmitting posts (DT Light Post Illusion) and the other half with opaque posts (Tech 21 X-OP). In both groups the following combinations of adhesive/cement were tested: OptiBond Solo Plus/Nexus Third Generation (NX3), XP Bond/SureFil SDR Flow (SDR), and Vertise Flow (VF). Push-out test was used to assess the retentive strength of fiber posts, which was expressed in megapascals (MPa). Specimens were analyzed under a stereomicroscope to determine failure mode (adhesive between luting agent and post, adhesive between luting agent and dentin or mixed failure). Push-out data and failure mode distribution were analyzed by two-way ANOVA and Chi-square test, respectively (P< 0.05). The statistical analysis revealed that only the type of luting material significantly influenced push-out bond strength of the post (P< 0.001). SDR (9.00 +/- 2.17 MPa) performed similarly to the control group NX3 (7.15 +/- 1.74 MPa), while VF (4.81 +/- 1.51 MPa) should significantly lower bond strength. Failure modes differed significantly among groups.


    • 1 October 2013
      • Vol. 26  (5) , 271-7

    Microleakage of Class II restorations and microtensile bond strength to dentin of low-shrinkage composites.

    by Jelena Juloski, Michele Carrabba, Juan Manuel Aragoneses, Leopoldo Forner, Alessandro Vichi, Marco Ferrari

    To evaluate the microleakage of Class II cavities restored with experimental low-shrinking resin composites proposed for bulk filling and to measure their microtensile bond strength (microTBS) to dentin and compare to those of previously marketed low-shrinkage composites. Class II cavities (7 mm occluso-gingival height, 2 mm mesio-distal depth of the box, 4 mm occlusal depth, 4 mm bucco-lingual width) were prepared in 50 molars and randomly divided into five groups (n = 10), according to the material: SureFil SDR flow (SDR), Filtek Silorane (FS) and experimental materials (G-aenial Flo bulk fill, GF; G-aenial Universal Flo bulk fill, GUF; GC Kalore bulk fill, GK). Microleakage was separately assessed at enamel and dentin margins by scoring the depth of silver-nitrate penetration. Twenty teeth divided into five groups (n = 4) were selected for microTBS testing. The same materials as for microleakage assessment were placed in bulk to mid-coronal dentin. Microtensile beams were loaded in tension, and microTBS at failure was calculated in MPa. Microleakage and microTBS data were analyzed by ANOVA on ranks, followed Dunn's post hoc test (P< 0.05). Microleakage was not observed at the enamel interface in any of the groups. At the dentin interface, SDR recorded significantly higher microleakage than the other materials. microTBS of GF, GUF and GK did not differ among each other (33 +/- 12 MPa, 31 +/- 11 MPa, 30 +/- 9 MPa, respectively), while SDR (63 +/- 17 MPa) and FS (55 +/- 17MPa) achieved significantly higher microTBS values. No direct association between the sealing properties and the bond strength values was observed.


    • 1 April 2013
      • Vol. 26  (2) , 99-104

    Influence of selective enamel etching on the bonding effectiveness of a new "all-in-one" adhesive.

    by Cecilia Goracci, Carlo Rengo, Leonardo Eusepi, Jelena Juloski, Alessandro Vichi, Marco Ferrari

    To evaluate in vitro the all-in-one adhesive G-Bond Plus/G-aenial Bond (GBP), used according to the selective enamel etching (SEE) technique, compared to Optibond FL, an etch-and-rinse adhesive tested as control (C). 133 molars provided specimens for enamel and dentin shear bond strength (SBS) testing, microleakage measurements in class 5 restorations, and scanning electron microscope observations of demineralization patterns produced by GBP and 37% phosphoric acid (PA). On enamel: C displayed the highest SBS. PA etching significantly increased enamel SBS of GBP. No statistically significant difference in SBS was noted among the bonding procedures on dentin. On both substrates, C revealed the most satisfactory seal. PA pre-etching did not significantly affect the sealing ability of GBP on either substrate.


    • 1 August 2012
      • Vol. 25  (4) , 239-43

    Enamel and dentin bond strength of new simplified adhesive materials with and without preliminary phosphoric acid-etching.

    by Jelena Juloski, Cecilia Goracci, Carlo Rengo, Agostino Giovannetti, Alessandro Vichi, Zoran R Vulicevic, Marco Ferrari

    To assess the influence of preliminary phosphoric acid-etching on shear bond strength (SBS) to enamel and dentin of a self-adhering restorative composite and of a new self-etch adhesive used in combination with the proprietary flowable composite. 100 human molars were selected. SBS was assessed on flat buccal enamel surfaces and mid-coronal dentin. Teeth from each group were divided into five subgroups (n=10): (1) FL: etch-and-rinse adhesive OptiBond FL/Premise flowable; (2) XTR: 2-step self-etch adhesive OptiBond XTR/Premise flowable; (3) eXTR: OptiBond XTR on etched substrates/Premise flowable; (4) VF: self-adhering flowable composite Vertise Flow; (5) eVF: Vertise Flow on etched substrates. Specimens were stressed in shear until failure. Failure modes were evaluated under a stereomicroscope. Data were analyzed by two-way ANOVA and Fisher's exact test (P< 0.05). Dental substrate, material and between-factor interaction significantly influenced SBS (MPa). In FL group (16.83 +/- 2.93) significantly higher SBS to enamel than in the other groups (XTR 8.59 +/- 4.39; eXTR 7.04 +/- 3.63; VF 6.61 +/- 2,41; eVF 9.87 +/- 4.24) was measured. On dentin FL (8.15 +/- 3.88) performed similarly to XTR (10.60 +/- 5.0), eXTR (9.60 +/- 4.91) and eVF (5.48 +/- 4.94); VF recorded significantly lower SBS (2.94 +/- 2.79 MPa). Failure modes differed significantly among groups.


    • 1 April 2012
      • Vol. 25  (2) , 73-8

    Influence of surface pretreatment on the short-term bond strength of resin composite to a zirconia-based material.

    by Giovanni Fazi, Alessandro Vichi, Marco Ferrari

    To evaluate the influence of airborne-particle abrasion of zirconia before and after sintering, on the bond strength between a zirconia core and an indirect resin composite material. 9 disks of Y-TZP zirconia core were prepared and divided into three equal groups. In Group 1 pre-sintered Y-TZP zirconia was airborne-particle abraded with 120 microm alumina oxide. In Group 2 sintered Y-TZP zirconia was airborne-particle abraded with 120 microm alumina oxide. In Group 3 sintered Y-TZP zirconia was not treated and thus served as the control group. A 10-methacryloylooxydecyldihydrogenphosphate (MDP) containing bonding agent and silane coupling agent mixture was applied to the disks in all three experimental groups. Resin composite for indirect restorations was incrementally layered in a plastic mold to a final thickness of 3 mm. Specimens were sectioned under water cooling to obtain microsticks 6 x 1 x 1 mm in dimension. 30 microsticks per experimental group were generated. Microtensile bond strength test was conducted with a universal testing machine. Fractured microsticks and sections from each group were also examined under an optical microscope and a scanning electron microscope to evaluate respectively the mode of failure and the zirconia-composite interface. T-test for independent samples was selected to analyze the data. The level of significance was set at P < 0.05. Airborne-particle abraded groups resulted in mean (SD) bond strength values of 25.65 (7.23) MPa for Group 1 and 24.65 (12.33) MPa for Group 2. Bond failures were mainly interfacial. In the control group a high number of premature failures occurred during cutting process and the mean (SD) bond strength recorded was 3.36 (4.17) MPa. It was concluded that airborne-particle abrasion of a zirconia substrate combined with application of a MDP-containing bonding/silane coupling agent mixture resulted in an adequate resin composite bond. Airborne-particle abrasion performed before sintering zirconia did not produce any significant differences.


    • 1 February 2012
      • Vol. 25  (1) , 17-20

    Influence of post type on degree of conversion of a resin-based luting agent.

    by Chiara Ottavia Navarra, Cecilia Goracci, Lorenzo Breschi, Alessandro Vichi, Gabriele Corciolani, Milena Cadenaro, Marco Ferrari

    To assess the degree of conversion (DC) at different levels of a resin-based luting agent used with different commercial posts. A resin-based luting agent (Variolink II) was light-cured in a simulated dowel space in combination with different fiber posts: GC Fiber Post (GC), DT Light Safety Lock (SL), RelyX Fiber Post (RX), Reforpost (RE), DT Light Post Illusion (LPI), FRC Postec Plus (FP), Radix (RA), Snowpost (SP), Dentin Post X (DP), Macrolock Illusion (MI), and Composipost (CP). After 24 hours, DC was assessed through micro-Raman analysis at the coronal, middle, and apical thirds. Two-way ANOVA and Tukey test were used for post-hoc comparisons (P<0.05). The results demonstrated that the post-type, dowel space level, and between-factor interaction were statistically significant (P<0.001). Differences in DC were observed at different depths for RX, RE, LPI, SL, DP, MI and CP, decreasing from the coronal to the apical third. Although the resin-based luting agent should be able to polymerize in absence of light, a higher DC was found following light irradiation (with a decreasing effect from the coronal to the apical third).