FRFernando Romero-Borja

Fernando Romero-Borja

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fernando Romero-Borja has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • Austin Roorda

    Herbert Wertheim School of Optometry & Vision Science, University of California, Berkeley

    1 shared publication
  • Krishnakumar Venkateswaran

    When this research was performed, F. Romero-Borja, K. Venkateswaran, and A. Roorda were with the College of Optometry, University of Houston, 4800 Calhoun Road, Houston, Texas 77204-2020

    1 shared publication
  • Thomas Hebert

    T. Hebert is with the Cullen College of Engineering, University of Houston, 4800 Calhoun Road, Houston, Texas 77204-4007

    1 shared publication

Latest Publications

  • Optical slicing of human retinal tissue in vivo with the adaptive optics scanning laser ophthalmoscope

    by Fernando Romero-Borja, Krishnakumar Venkateswaran, Austin Roorda, Thomas Hebert

    We present imaging results in human retinal tissue in vivo that allowed us to determine the axial resolution of the adaptive optics scanning laser ophthalmoscope (AOSLO). The instrument is briefly described, and the imaging results from human subjects are compared with (a) the estimated axial resolution values for a diffraction-limited, double-pass instrument and (b) the measured one for a calibrated diffuse retinal model. The comparison showed that the measured axial resolution, as obtained from optical sectioning of human retinas in vivo, can be as low as 71 µm for a 50 µm confocal pinhole after focusing a 3.5 mm beam with a 100 mm focal-length lens. The axial resolution values typically fall between the predictions from numerical models for diffuse and specular reflectors. This suggests that the reflection from the retinal blood vessel combines diffuse and specular components. This conclusion is supported by the almost universal interpretation that the image of a cylindrical blood vessel exhibits a bright reflection along its apex that is considered specular. The enhanced axial resolution achieved through use of adaptive optics leads to an improvement in the volume resolution of almost 2 orders of magnitude when compared with a conventional scanning laser ophthalmoscope and almost a factor of 3 better than commercially available optical coherence tomographic instruments.