B. Oldroyd
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
B. Oldroyd has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
J G Truscott
Centre for Bone and Body Composition Research, University of Leeds, UK
2 shared publicationsA H Smith
Centre for Bone and Body Composition Research, University of Leeds, UK
1 shared publicationA Horsman
Department of Applied Biology, University of Hull , Hull, UK
1 shared publicationA. Morton
Leeds Teaching Hospitals, Leeds, UK
1 shared publicationC F Westmacott
Centre for Bone and Body Composition Research, Insititute of Physical Sciences, Department of Clinical Medicine, University of Leeds , Wellcome Wing, The General Infirmary, Leeds LS1 3EX
1 shared publicationJ. Truscott
University of Leeds, Leeds, UK
1 shared publication
Latest Publications
- 24 July 2003
- Published by Springer Nature in European Journal of Clinical Nutrition
- Vol. 57 (8) , 977-987
Cross-calibration of GE/Lunar pencil and fan-beam dual energy densitometers—bone mineral density and body composition studies
Objective: In vitro and in vivo comparisons of bone mineral density (BMD) and body composition between GE/Lunar pencil (DPXL) and fan-beam (PRODIGY) absorptiometers. Design: Comparison of BMD, bone mineral content (BMC) and area of lumbar spine (L2–L4), femoral neck and total body. Total body composition compartments tissue (TBTissue), fat (TBF), lean tissue (TBLean) and %TBF were also compared. Setting: Centre for Bone and Body Composition Research, University of Leeds. Phantoms/subjects: A range of spine phantoms, a variable composition phantom (VCP) and total body phantom. A total of 72 subjects were included for the in vivo study. Results: In vitro: A small significant underestimation of BMD by the Prodigy compared to the DPXL ranging from 0.7 to 2% (pIn vivo: BMD cross-calibration was only required in the femoral neck, DPXLBMD=0.08+0.906*PRODIGYBMD. The Prodigy had higher estimates for TBTissue 1360 g (2.3%), TBLean 840 g (2.0%), TBF 519 g (3.4%), TBBMC 32.8 g (1.3%) and %TBF (0.3%). Cross-calibration equations were required for TBTissueDPXL=-1158+0.997*TBTissuePRODIGY and TBBMCDPXL= 89.7+0.949*TBBMCPRODIGY. Conclusions: Small differences between the two absorptiometers for both BMD and body composition can be made compatible by use of cross-calibration equations and factors. The discrepancy in body composition compartments requires further research.
- 24 July 2003
- Published by Springer Nature in European Journal of Clinical Nutrition
- Vol. 57 (8) , 977-987
Cross-calibration of GE/Lunar pencil and fan-beam dual energy densitometers—bone mineral density and body composition studies
Objective: In vitro and in vivo comparisons of bone mineral density (BMD) and body composition between GE/Lunar pencil (DPXL) and fan-beam (PRODIGY) absorptiometers. Design: Comparison of BMD, bone mineral content (BMC) and area of lumbar spine (L2–L4), femoral neck and total body. Total body composition compartments tissue (TBTissue), fat (TBF), lean tissue (TBLean) and %TBF were also compared. Setting: Centre for Bone and Body Composition Research, University of Leeds. Phantoms/subjects: A range of spine phantoms, a variable composition phantom (VCP) and total body phantom. A total of 72 subjects were included for the in vivo study. Results: In vitro: A small significant underestimation of BMD by the Prodigy compared to the DPXL ranging from 0.7 to 2% (pIn vivo: BMD cross-calibration was only required in the femoral neck, DPXLBMD=0.08+0.906*PRODIGYBMD. The Prodigy had higher estimates for TBTissue 1360 g (2.3%), TBLean 840 g (2.0%), TBF 519 g (3.4%), TBBMC 32.8 g (1.3%) and %TBF (0.3%). Cross-calibration equations were required for TBTissueDPXL=-1158+0.997*TBTissuePRODIGY and TBBMCDPXL= 89.7+0.949*TBBMCPRODIGY. Conclusions: Small differences between the two absorptiometers for both BMD and body composition can be made compatible by use of cross-calibration equations and factors. The discrepancy in body composition compartments requires further research.
- 1 June 1993
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 66 (786) , 514-521
Variation in lumbar spine and femoral neck bone mineral measured by dual energy X-ray absorption: a study of 329 normal women
Reference ranges used in dual energy X-ray absorptiometry (DXA) have previously used piecewise linear fits to the whole data set for spine or femur bone mineral density (BMD) as a function of age. In a study of 329 Caucasian normal women we present a refinement to the normal range by fitting straight lines between quinquennial mean values of BMD for each site measured (lumbar spine, femoral neck and Ward's triangle). From the age of 40 years onwards the premenopausal women demonstrated minimal loss of BMD whereas postmenopausal women showed a rapid loss amounting to 27% in the lumbar spine, 27% in the femoral neck and 38% in the Ward's triangle region in the age range under examination. Comparison of quinquennial means for pre and postmenopausal women in age bands 45-49 years and 50-54 years shows that at these ages postmenopausal BMD is significantly lower than premenopausal BMD (P < 0.05). This finding suggests that separate normal ranges should be used for pre and postmenopausal women. As reduction in the production of oestrogen is a major factor in postmenopausal bone loss and oestrogen function is related to years since menopause (YSM), a more logical way of displaying postmenopausal normal BMD ranges would be in terms of YSM rather than chronological age. Such data are given in this paper.
- 1 June 1993
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 66 (786) , 514-521
Variation in lumbar spine and femoral neck bone mineral measured by dual energy X-ray absorption: a study of 329 normal women
Reference ranges used in dual energy X-ray absorptiometry (DXA) have previously used piecewise linear fits to the whole data set for spine or femur bone mineral density (BMD) as a function of age. In a study of 329 Caucasian normal women we present a refinement to the normal range by fitting straight lines between quinquennial mean values of BMD for each site measured (lumbar spine, femoral neck and Ward's triangle). From the age of 40 years onwards the premenopausal women demonstrated minimal loss of BMD whereas postmenopausal women showed a rapid loss amounting to 27% in the lumbar spine, 27% in the femoral neck and 38% in the Ward's triangle region in the age range under examination. Comparison of quinquennial means for pre and postmenopausal women in age bands 45-49 years and 50-54 years shows that at these ages postmenopausal BMD is significantly lower than premenopausal BMD (P < 0.05). This finding suggests that separate normal ranges should be used for pre and postmenopausal women. As reduction in the production of oestrogen is a major factor in postmenopausal bone loss and oestrogen function is related to years since menopause (YSM), a more logical way of displaying postmenopausal normal BMD ranges would be in terms of YSM rather than chronological age. Such data are given in this paper.