Shmuel Einav
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Shmuel Einav has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Amit Pascal1 shared publication
Bronislav Herman
Department of Biomedical Engineering, Faculty of Engineering, Tel-Aviv University, Tel-Aviv, Israel
1 shared publicationDanny Bluestein
Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York 11794, USA
1 shared publicationDavid Castel
Neufeld Cardiac Research Institute, Tel-Aviv University, Sheba Medical Center, Israel
1 shared publicationEli Flaxer
AFEKA, The Tel-Aviv Academic College of Engineering
1 shared publicationEran Toledo
The Abramson Center for Medical Physics, Sackler Faculty of Exact Sciences, Tel-Aviv University, Israel
1 shared publication
Latest Publications
- Open Access
- 1 January 2016
- Published by Avestia Publishing in Journal of Biomedical Engineering and Biosciences
- Vol. 3, 1-3
Mechanical Simulator of the Small Intestine for In-Vitro Practice with Endoscopic Devices
The Volume 1, Issue 1 published for JBB Journal.
- 1 January 2016
- Published by Avestia Publishing in Journal of Biomedical Engineering and Biosciences
- Vol. 3, 1-3
Open AccessMechanical Simulator of the Small Intestine for In-Vitro Practice with Endoscopic Devices
The Volume 1, Issue 1 published for JBB Journal.
- 6 July 2011
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 2 (3) , 228-233
Detection of Microcalcification in Tissue by Raman Spectroscopy
- 6 July 2011
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 2 (3) , 228-233
Detection of Microcalcification in Tissue by Raman Spectroscopy
- 1 May 2004
- Published by Wiley in Annals of the New York Academy of Sciences
- Vol. 1015 (1) , 351-366
Dynamics of Blood Flow and Platelet Transport in Pathological Vessels
Abstract: Arterial disease, characterized by arterial occlusion (stenosis), is a leading cause of cardiovascular diseases and a major healthcare problem in the Western world. One of the main mechanisms leading to vessel occlusion is thrombus formation, which may be initiated by platelet activation. Shear rates and flow patterns (fluid dynamics factors) and concentration of coagulation factors and platelet agonists (biological factors) modulate platelet function and may lead to platelet activation and aggregation. Here, we examine the flow‐induced mechanisms leading to platelet activation in models of stenosed coronary vessels. Experimental and numerical methods were used to investigate and characterize the influence of the flow field on platelet activation. As it passes through pathological geometries characteristic of arterial stenosis, a platelet is exposed to varying levels of shear stress. The cumulative effect of the shear stress level and the duration of the platelet's exposure to it determine whether the platelet is brought beyond its activation threshold. Stress histories of individual platelets can be tracked within the flow field to locate the regions where activated platelets might be found and subsequently aggregate and/or adhere to the wall.
- 1 May 2004
- Published by Wiley in Annals of the New York Academy of Sciences
- Vol. 1015 (1) , 351-366
Dynamics of Blood Flow and Platelet Transport in Pathological Vessels
Abstract: Arterial disease, characterized by arterial occlusion (stenosis), is a leading cause of cardiovascular diseases and a major healthcare problem in the Western world. One of the main mechanisms leading to vessel occlusion is thrombus formation, which may be initiated by platelet activation. Shear rates and flow patterns (fluid dynamics factors) and concentration of coagulation factors and platelet agonists (biological factors) modulate platelet function and may lead to platelet activation and aggregation. Here, we examine the flow‐induced mechanisms leading to platelet activation in models of stenosed coronary vessels. Experimental and numerical methods were used to investigate and characterize the influence of the flow field on platelet activation. As it passes through pathological geometries characteristic of arterial stenosis, a platelet is exposed to varying levels of shear stress. The cumulative effect of the shear stress level and the duration of the platelet's exposure to it determine whether the platelet is brought beyond its activation threshold. Stress histories of individual platelets can be tracked within the flow field to locate the regions where activated platelets might be found and subsequently aggregate and/or adhere to the wall.
- 7 February 2002
- Published by SAGE Publications in Technology and Health Care
- Vol. 10 (1) , 39-56
The area of the pressure – flow loop for assessment of arterial stenosis: A new index
This study describes a novel method for assessing stenotic severity, based on simultaneous pressure and flow wave measurements. Pressure and flow measurements were performed in latex and rubber tubes, and in a clinically-used vascular graft. Pressure
- 7 February 2002
- Published by SAGE Publications in Technology and Health Care
- Vol. 10 (1) , 39-56
The area of the pressure – flow loop for assessment of arterial stenosis: A new index
This study describes a novel method for assessing stenotic severity, based on simultaneous pressure and flow wave measurements. Pressure and flow measurements were performed in latex and rubber tubes, and in a clinically-used vascular graft. Pressure
- 16 August 2001
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 124 (1) , 21-29
Unsteady Effects on the Flow Across Tilting Disk Valves
The present study simulates numerically the flow across two-dimensional tilting disk models of mechanical heart valves. The time-dependent Navier-Stokes equations are solved to assess the importance of unsteady effects in the fully open position of the valve. Flow cases with steady or physiological inflow conditions and with fixed or moving valves are solved. The simulations lead into mixed conclusions. It is obvious that steady inflow cases that account for vortex shedding only cannot model realistic physiological cases. In cases with imposed physiological inflow, the details of the flow field for fixed and moving valves might differ in the fully open position as well, although the gross features are quite similar. The fixed valve case consistently results in safe estimations of several critical quantities such as the axial force, the maximal shear stress on the valve, or the transvalvular pressure drop. Thus, fixed valve simulations can provide useful information for the design of prosthetic heart valves, as long as the properties in the fully open position only are sought.
- 16 August 2001
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 124 (1) , 21-29
Unsteady Effects on the Flow Across Tilting Disk Valves
The present study simulates numerically the flow across two-dimensional tilting disk models of mechanical heart valves. The time-dependent Navier-Stokes equations are solved to assess the importance of unsteady effects in the fully open position of the valve. Flow cases with steady or physiological inflow conditions and with fixed or moving valves are solved. The simulations lead into mixed conclusions. It is obvious that steady inflow cases that account for vortex shedding only cannot model realistic physiological cases. In cases with imposed physiological inflow, the details of the flow field for fixed and moving valves might differ in the fully open position as well, although the gross features are quite similar. The fixed valve case consistently results in safe estimations of several critical quantities such as the axial force, the maximal shear stress on the valve, or the transvalvular pressure drop. Thus, fixed valve simulations can provide useful information for the design of prosthetic heart valves, as long as the properties in the fully open position only are sought.
- 1 June 2000
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 26 (5) , 797-806
Feasibility of mitral flow assessment by echo-contrast ultrasound, part II: experimental study on a mechanical model of the left heart
- 1 June 2000
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 26 (5) , 797-806
Feasibility of mitral flow assessment by echo-contrast ultrasound, part II: experimental study on a mechanical model of the left heart