Wendie A. Berg
Research Subjects
Wendie A. Berg has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Ellen B. Mendelson
2 shared publicationsJean B. Cormack
2 shared publicationsJeffrey D. Blume
2 shared publicationsDeepa Narayanan
Naviscan PET Systems, Inc., Rockville, Maryland; Departments of
1 shared publicationEdward A. Levine
Department of Surgery, Wake Forest University Baptist Medical Center, Winston‐Salem, North Carolina
1 shared publicationEric Ross
Department of Biostatistics and
1 shared publication
Latest Publications
- 1 November 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 241 (2) , 355-365
Operator Dependence of Physician-performed Whole-Breast US: Lesion Detection and Characterization
To prospectively examine operator dependence of lesion detection, description, and interpretation when experienced breast radiologists perform whole-breast ultrasonography (US). Institutional review board approval was obtained for the HIPAA-compliant study. Ten women (aged 19-53 years; mean, 37.4 years; 20 breasts) with numerous known breast lesions consented to participate. Eleven breast radiologists, who passed experience and qualification requirements for a screening breast US trial and consented to participate, scanned both breasts in all participants and documented images of each detected lesion and its size, location, features, palpability, and Breast Imaging Reporting and Data System final assessment. Intraclass correlation coefficients (ICCs) were used to measure agreement on lesion size and location, and kappa statistics were calculated for agreement on features and final assessments compared with consensus. Eighty-eight unique lesions were identified by at least two investigators (five to 13 lesions per participant). Mean diameter was 6.7 mm (standard error, 0.4; range, 2-22 mm), and eight lesions (9%) were palpable. Of 968 potential detections (88 lesions, 11 investigators), 536 (55%) detections were made. Individual investigators detected between 43 (49%) and 58 (66%) lesions. Larger lesions were more consistently detected: Detection rates were six of 33 lesions (18%) at 3 mm or smaller; 164 of 374 (43.9%) at 3.1-5 mm; 145 of 275 (52.7%) at 5.1-7 mm; 119 of 176 (67.6%) at 7.1-9 mm; 38 of 44 (86%) at 9.1-11 mm; and 64 of 66 (97%) lesions larger than 11 mm (P < .001). ICCs for clockface, distance from nipple, and individual lesion diameter all exceeded 0.7, indicating high reliability. For shape, margins, and final assessments of solid lesions, kappa values were 0.62, 0.67 (substantial agreement), and 0.52 (moderate agreement), respectively. Of 110 detections of consensus cysts 8 mm and smaller, 15 (14%) detections were considered to be of solid lesions by at least one reader. Larger lesions (>11 mm) are most consistently detected, with fewer than half of lesions 5 mm or smaller in mean diameter identified; substantial agreement was found for description of lesion size, location, and key features, and moderate agreement was found for lesion management.
- 1 November 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 241 (2) , 355-365
Operator Dependence of Physician-performed Whole-Breast US: Lesion Detection and Characterization
To prospectively examine operator dependence of lesion detection, description, and interpretation when experienced breast radiologists perform whole-breast ultrasonography (US). Institutional review board approval was obtained for the HIPAA-compliant study. Ten women (aged 19-53 years; mean, 37.4 years; 20 breasts) with numerous known breast lesions consented to participate. Eleven breast radiologists, who passed experience and qualification requirements for a screening breast US trial and consented to participate, scanned both breasts in all participants and documented images of each detected lesion and its size, location, features, palpability, and Breast Imaging Reporting and Data System final assessment. Intraclass correlation coefficients (ICCs) were used to measure agreement on lesion size and location, and kappa statistics were calculated for agreement on features and final assessments compared with consensus. Eighty-eight unique lesions were identified by at least two investigators (five to 13 lesions per participant). Mean diameter was 6.7 mm (standard error, 0.4; range, 2-22 mm), and eight lesions (9%) were palpable. Of 968 potential detections (88 lesions, 11 investigators), 536 (55%) detections were made. Individual investigators detected between 43 (49%) and 58 (66%) lesions. Larger lesions were more consistently detected: Detection rates were six of 33 lesions (18%) at 3 mm or smaller; 164 of 374 (43.9%) at 3.1-5 mm; 145 of 275 (52.7%) at 5.1-7 mm; 119 of 176 (67.6%) at 7.1-9 mm; 38 of 44 (86%) at 9.1-11 mm; and 64 of 66 (97%) lesions larger than 11 mm (P < .001). ICCs for clockface, distance from nipple, and individual lesion diameter all exceeded 0.7, indicating high reliability. For shape, margins, and final assessments of solid lesions, kappa values were 0.62, 0.67 (substantial agreement), and 0.52 (moderate agreement), respectively. Of 110 detections of consensus cysts 8 mm and smaller, 15 (14%) detections were considered to be of solid lesions by at least one reader. Larger lesions (>11 mm) are most consistently detected, with fewer than half of lesions 5 mm or smaller in mean diameter identified; substantial agreement was found for description of lesion size, location, and key features, and moderate agreement was found for lesion management.
- 1 July 2006
- Published by Wiley in The Breast Journal
- Vol. 12 (4) , 309-323
High-Resolution Fluorodeoxyglucose Positron Emission Tomography with Compression ("Positron Emission Mammography") is Highly Accurate in Depicting Primary Breast Cancer
We sought to prospectively assess the diagnostic performance of a high-resolution positron emission tomography (PET) scanner using mild breast compression (positron emission mammography [PEM]). Data were collected on concomitant medical conditions to assess potential confounding factors. At four centers, 94 consecutive women with known breast cancer or suspicious breast lesions received 18F-fluorodeoxyglucose (FDG) intravenously, followed by PEM scans. Readers were provided clinical histories and x-ray mammograms (when available). After excluding inevaluable cases and two cases of lymphoma, PEM readings were correlated with histopathology for 92 lesions in 77 women: 77 index lesions (42 malignant), 3 ipsilateral lesions (3 malignant), and 12 contralateral lesions (3 malignant). Of 48 cancers, 16 (33%) were clinically evident; 11 (23%) were ductal carcinoma in situ (DCIS), and 37 (77%) were invasive (30 ductal, 4 lobular, and 3 mixed; median size 21 mm). PEM depicted 10 of 11 (91%) DCIS and 33 of 37 (89%) invasive cancers. PEM was positive in 1 of 2 T1a tumors, 4 of 6 T1b tumors, 7 of 7 T1c tumors, and 4 of 4 cases where tumor size was not available (e.g., no surgical follow-up). PEM sensitivity for detecting cancer was 90%, specificity 86%, positive predictive value (PPV) 88%, negative predictive value (NPV) 88%, accuracy 88%, and area under the receiver-operating characteristic curve (Az) 0.918. In three patients, cancer foci were identified only on PEM, significantly changing patient management. Excluding eight diabetic subjects and eight subjects whose lesions were characterized as clearly benign with conventional imaging, PEM sensitivity was 91%, specificity 93%, PPV 95%, NPV 88%, accuracy 92%, and Az 0.949 when interpreted with mammographic and clinical findings. FDG PEM has high diagnostic accuracy for breast lesions, including DCIS.
- 1 July 2006
- Published by Wiley in The Breast Journal
- Vol. 12 (4) , 309-323
High-Resolution Fluorodeoxyglucose Positron Emission Tomography with Compression ("Positron Emission Mammography") is Highly Accurate in Depicting Primary Breast Cancer
We sought to prospectively assess the diagnostic performance of a high-resolution positron emission tomography (PET) scanner using mild breast compression (positron emission mammography [PEM]). Data were collected on concomitant medical conditions to assess potential confounding factors. At four centers, 94 consecutive women with known breast cancer or suspicious breast lesions received 18F-fluorodeoxyglucose (FDG) intravenously, followed by PEM scans. Readers were provided clinical histories and x-ray mammograms (when available). After excluding inevaluable cases and two cases of lymphoma, PEM readings were correlated with histopathology for 92 lesions in 77 women: 77 index lesions (42 malignant), 3 ipsilateral lesions (3 malignant), and 12 contralateral lesions (3 malignant). Of 48 cancers, 16 (33%) were clinically evident; 11 (23%) were ductal carcinoma in situ (DCIS), and 37 (77%) were invasive (30 ductal, 4 lobular, and 3 mixed; median size 21 mm). PEM depicted 10 of 11 (91%) DCIS and 33 of 37 (89%) invasive cancers. PEM was positive in 1 of 2 T1a tumors, 4 of 6 T1b tumors, 7 of 7 T1c tumors, and 4 of 4 cases where tumor size was not available (e.g., no surgical follow-up). PEM sensitivity for detecting cancer was 90%, specificity 86%, positive predictive value (PPV) 88%, negative predictive value (NPV) 88%, accuracy 88%, and area under the receiver-operating characteristic curve (Az) 0.918. In three patients, cancer foci were identified only on PEM, significantly changing patient management. Excluding eight diabetic subjects and eight subjects whose lesions were characterized as clearly benign with conventional imaging, PEM sensitivity was 91%, specificity 93%, PPV 95%, NPV 88%, accuracy 92%, and Az 0.949 when interpreted with mammographic and clinical findings. FDG PEM has high diagnostic accuracy for breast lesions, including DCIS.
- 1 June 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 239 (3) , 693-702
Lesion Detection and Characterization in a Breast US Phantom: Results of the ACRIN 6666 Investigators
To prospectively evaluate ultrasonographic (US) lesion detection and characterization in a breast phantom by potential investigators in a screening US protocol, American College of Radiology Imaging Network (ACRIN) 6666. National Cancer Institute Cancer Experimental Therapeutic Protocol review and ACRIN internal institutional review board approved the protocol; potential investigators were informed of the study purpose prior to participation. Six equivalent anthropomorphic phantoms were prepared with 17 masses (2-10 mm in mean diameter) in different locations at different depths. Sixty-six investigators, experienced in breast US, from 23 institutions scanned a phantom with high-frequency linear-array transducers (12-5 MHz). Lesion location, diameters, echogenicity, shape, and posterior features were recorded. Reader-specific phantom maps were generated and compared with known lesion locations and features. Results from 64 observers could be analyzed and were masked to investigator identity. Agreement on US features was measured with kappa statistics. A generalized linear model generated log relative risks for detection rates as a function of lesion diameter, depth, and features. Of 17 lesions, a median of 14 (82%) were detected (range, 9-16), and 86% of observers detected at least 12 lesions. Of 1088 potential detections, 861 (79.1%) were made. Among 5-10-mm lesions, 499 (97.5%) of 512 detections were made (excluding a 6-mm "skin" lesion seen by only seven observers [11%]). One 4-mm mass was seen by 53 observers (83%). Among 3-mm lesions, 274 (71.4%) of 384 detections were made. One 2-mm lesion was seen by 28 (44%) observers. Relative risk of detection decreased to 0.55 (95% confidence interval: 0.51, 0.59) for each centimeter increase in lesion depth. Agreement was slight for lesion shape (kappa=0.14), substantial for echogenicity (kappa=0.61), and moderate for posterior features (kappa=0.45). Feature description errors were common for 2-4-mm lesions; only 33% of 3-mm anechoic masses were so characterized. Among eight 6-10-mm lesions, investigators erred in feature description of a median of 1 lesion (mean, 1.3; range, 0-4). US detection and description of lesions in a breast phantom were highly consistent for lesions 5-10 mm in diameter; those smaller than 5 mm were less reliably identified or characterized by experienced investigators.
- 1 June 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 239 (3) , 693-702
Lesion Detection and Characterization in a Breast US Phantom: Results of the ACRIN 6666 Investigators
To prospectively evaluate ultrasonographic (US) lesion detection and characterization in a breast phantom by potential investigators in a screening US protocol, American College of Radiology Imaging Network (ACRIN) 6666. National Cancer Institute Cancer Experimental Therapeutic Protocol review and ACRIN internal institutional review board approved the protocol; potential investigators were informed of the study purpose prior to participation. Six equivalent anthropomorphic phantoms were prepared with 17 masses (2-10 mm in mean diameter) in different locations at different depths. Sixty-six investigators, experienced in breast US, from 23 institutions scanned a phantom with high-frequency linear-array transducers (12-5 MHz). Lesion location, diameters, echogenicity, shape, and posterior features were recorded. Reader-specific phantom maps were generated and compared with known lesion locations and features. Results from 64 observers could be analyzed and were masked to investigator identity. Agreement on US features was measured with kappa statistics. A generalized linear model generated log relative risks for detection rates as a function of lesion diameter, depth, and features. Of 17 lesions, a median of 14 (82%) were detected (range, 9-16), and 86% of observers detected at least 12 lesions. Of 1088 potential detections, 861 (79.1%) were made. Among 5-10-mm lesions, 499 (97.5%) of 512 detections were made (excluding a 6-mm "skin" lesion seen by only seven observers [11%]). One 4-mm mass was seen by 53 observers (83%). Among 3-mm lesions, 274 (71.4%) of 384 detections were made. One 2-mm lesion was seen by 28 (44%) observers. Relative risk of detection decreased to 0.55 (95% confidence interval: 0.51, 0.59) for each centimeter increase in lesion depth. Agreement was slight for lesion shape (kappa=0.14), substantial for echogenicity (kappa=0.61), and moderate for posterior features (kappa=0.45). Feature description errors were common for 2-4-mm lesions; only 33% of 3-mm anechoic masses were so characterized. Among eight 6-10-mm lesions, investigators erred in feature description of a median of 1 lesion (mean, 1.3; range, 0-4). US detection and description of lesions in a breast phantom were highly consistent for lesions 5-10 mm in diameter; those smaller than 5 mm were less reliably identified or characterized by experienced investigators.
- 1 October 2005
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 185 (4) , 952-959
Sonographically Depicted Breast Clustered Microcysts: Is Follow-Up Appropriate?
OBJECTIVE. The objective of this study was to evaluate outcomes of lesions prospectively classified on breast sonography as clustered microcysts without a discrete solid component.SUBJECTS AND METHODS. Over a 4-year interval during which 1,900 consecutive breast sonography examinations were obtained at the University of Maryland, 110 examinations (5.8%) yielded 123 lesions so classified. Sonography was performed by a physician using a linear-array broadband transducer (L7.5–12 or L7–13 MHz). Follow-up of at least 24 months was available for 66 lesions, and 14-gauge core biopsy was performed on another 13 lesions. The median patient age was 48 years (range, 32–71 years), and the median lesion size was 8 mm (range, 5–30 mm).RESULTS. Of the 79 lesions with acceptable follow-up, all were depicted sonographically, 57 (72%) were seen mammographically, and four (5%) were palpable. Of the 13 lesions biopsied, five (38%) showed apocrine metaplasia; five (38%), fibrocystic changes; two (15%), cysts; and one (8%), a...
- 1 October 2005
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 185 (4) , 952-959
Sonographically Depicted Breast Clustered Microcysts: Is Follow-Up Appropriate?
OBJECTIVE. The objective of this study was to evaluate outcomes of lesions prospectively classified on breast sonography as clustered microcysts without a discrete solid component.SUBJECTS AND METHODS. Over a 4-year interval during which 1,900 consecutive breast sonography examinations were obtained at the University of Maryland, 110 examinations (5.8%) yielded 123 lesions so classified. Sonography was performed by a physician using a linear-array broadband transducer (L7.5–12 or L7–13 MHz). Follow-up of at least 24 months was available for 66 lesions, and 14-gauge core biopsy was performed on another 13 lesions. The median patient age was 48 years (range, 32–71 years), and the median lesion size was 8 mm (range, 5–30 mm).RESULTS. Of the 79 lesions with acceptable follow-up, all were depicted sonographically, 57 (72%) were seen mammographically, and four (5%) were palpable. Of the 13 lesions biopsied, five (38%) showed apocrine metaplasia; five (38%), fibrocystic changes; two (15%), cysts; and one (8%), a...
- Top Cited Papers
- 1 December 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 233 (3) , 830-849
Diagnostic Accuracy of Mammography, Clinical Examination, US, and MR Imaging in Preoperative Assessment of Breast Cancer
To prospectively assess accuracy of mammography, clinical examination, ultrasonography (US), and magnetic resonance (MR) imaging in preoperative assessment of local extent of breast cancer. Institutional review board approval and informed patient consent were obtained. Results of bilateral mammography, US, and contrast-enhanced MR imaging were analyzed from 111 consecutive women with known or suspected invasive breast cancer. Results were correlated with histopathologic findings. Analysis included 177 malignant foci in 121 cancerous breasts, of which 89 (50%) foci were palpable. Median size of 139 invasive foci was 18 mm (range, 2-107 mm). Mammographic sensitivity decreased from 100% in fatty breasts to 45% in extremely dense breasts. Mammographic sensitivity was highest for invasive ductal carcinoma (IDC) in 89 of 110 (81%) cases versus 10 of 29 (34%) cases of invasive lobular carcinoma (ILC) (P < .001) and 21 of 38 (55%) cases of ductal carcinoma in situ (DCIS) (P < .01). US showed higher sensitivity than did mammography for IDC, depicting 104 of 110 (94%) cases, and for ILC, depicting 25 of 29 (86%) cases (P < .01 for each). US showed higher sensitivity for invasive cancer than DCIS (18 of 38 [47%], P < .001). MR showed higher sensitivity than did mammography for all tumor types (P < .01) and higher sensitivity than did US for DCIS (P < .001), depicting 105 of 110 (95%) cases of IDC, 28 of 29 (96%) cases of ILC, and 34 of 38 (89%) cases of DCIS. In anticipation of conservation or no surgery after mammography and clinical examination in 96 breasts, additional tumor (which altered surgical approach) was present in 30. Additional tumor was depicted in 17 of 96 (18%) breasts at US and in 29 of 96 (30%) at MR, though extent was now overestimated in 12 of 96 (12%) at US and 20 of 96 (21%) at MR imaging. After combined mammography, clinical examination, and US, MR depicted additional tumor in another 12 of 96 (12%) breasts and led to overestimation of extent in another six (6%); US showed no detection benefit after MR imaging. Bilateral cancer was present in 10 of 111 (9%) patients; contralateral tumor was depicted mammographically in six and with both US and MR in an additional three. One contralateral cancer was demonstrated only clinically. In nonfatty breasts, US and MR imaging were more sensitive than mammography for invasive cancer, but both MR imaging and US involved risk of overestimation of tumor extent. Combined mammography, clinical examination, and MR imaging were more sensitive than any other individual test or combination of tests.
- 1 December 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 233 (3) , 830-849
Top Cited PapersDiagnostic Accuracy of Mammography, Clinical Examination, US, and MR Imaging in Preoperative Assessment of Breast Cancer
To prospectively assess accuracy of mammography, clinical examination, ultrasonography (US), and magnetic resonance (MR) imaging in preoperative assessment of local extent of breast cancer. Institutional review board approval and informed patient consent were obtained. Results of bilateral mammography, US, and contrast-enhanced MR imaging were analyzed from 111 consecutive women with known or suspected invasive breast cancer. Results were correlated with histopathologic findings. Analysis included 177 malignant foci in 121 cancerous breasts, of which 89 (50%) foci were palpable. Median size of 139 invasive foci was 18 mm (range, 2-107 mm). Mammographic sensitivity decreased from 100% in fatty breasts to 45% in extremely dense breasts. Mammographic sensitivity was highest for invasive ductal carcinoma (IDC) in 89 of 110 (81%) cases versus 10 of 29 (34%) cases of invasive lobular carcinoma (ILC) (P < .001) and 21 of 38 (55%) cases of ductal carcinoma in situ (DCIS) (P < .01). US showed higher sensitivity than did mammography for IDC, depicting 104 of 110 (94%) cases, and for ILC, depicting 25 of 29 (86%) cases (P < .01 for each). US showed higher sensitivity for invasive cancer than DCIS (18 of 38 [47%], P < .001). MR showed higher sensitivity than did mammography for all tumor types (P < .01) and higher sensitivity than did US for DCIS (P < .001), depicting 105 of 110 (95%) cases of IDC, 28 of 29 (96%) cases of ILC, and 34 of 38 (89%) cases of DCIS. In anticipation of conservation or no surgery after mammography and clinical examination in 96 breasts, additional tumor (which altered surgical approach) was present in 30. Additional tumor was depicted in 17 of 96 (18%) breasts at US and in 29 of 96 (30%) at MR, though extent was now overestimated in 12 of 96 (12%) at US and 20 of 96 (21%) at MR imaging. After combined mammography, clinical examination, and US, MR depicted additional tumor in another 12 of 96 (12%) breasts and led to overestimation of extent in another six (6%); US showed no detection benefit after MR imaging. Bilateral cancer was present in 10 of 111 (9%) patients; contralateral tumor was depicted mammographically in six and with both US and MR in an additional three. One contralateral cancer was demonstrated only clinically. In nonfatty breasts, US and MR imaging were more sensitive than mammography for invasive cancer, but both MR imaging and US involved risk of overestimation of tumor extent. Combined mammography, clinical examination, and MR imaging were more sensitive than any other individual test or combination of tests.
- 1 September 2004
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 42 (5) , 845-851
Supplemental screening sonography in dense breasts
- 1 September 2004
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 42 (5) , 845-851
Supplemental screening sonography in dense breasts
- 1 September 2004
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 42 (5) , 935-946
Image-guided breast biopsy and management of high-risk lesions
- 1 September 2004
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 42 (5) , 935-946
Image-guided breast biopsy and management of high-risk lesions