Masanori Ichise
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Masanori Ichise has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jeih-San Liow
Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD 20892, USA
3 shared publications - Robert B. Innis
Molecular Imaging Branch, National Institute of Mental Health, Bethesda, Maryland, USA
3 shared publications - Douglass C Vines
Molecular Imaging Branch, National Institute of Mental Health, Bethesda, MD, USA
2 shared publications Doug Vines
1 shared publicationDouglass C. Vines
1 shared publicationGeorge M. Anderson
1 shared publication
Latest Publications
- Open Access
- 26 April 2006
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 26 (17) , 4638-4643
Effects of Early Life Stress on [11C]DASB Positron Emission Tomography Imaging of Serotonin Transporters in Adolescent Peer- and Mother-Reared Rhesus Monkeys
Peer-reared (PR) rhesus monkeys with early maternal separation later exhibit aggressiveness, impaired impulse control, alcohol abuse, and low CSF 5-hydroxyindoleacetic acid. This study compared regional brain serotonin transporter (SERT) binding between nine PR and seven mother-reared rhesus monkeys with [11C]DASB positron emission tomography (PET) imaging. Parametric images of binding potential (BP) (which is proportional toBmax/KD, in whichBmaxis transporter density andKDis dissociation constant) and relative blood flow (R1) were generated by the two-parameter multilinear reference tissue model.R1images were used for coregistration and normalization of PET parametric data to the magnetic resonance imaging template space. Group BP differences were analyzed voxelwise by Student'sttest in SPM2. Region of interest-based parameter values were also calculated to obtain the magnitude of regional BP differences between the two groups. For the PR group, SERT BP was decreased by 10–23% across a range of brain areas consisting of the raphe, thalamus, hypothalamus, caudate and putamen, globus pallidum, anterior cingulate gyrus, and medial temporal regions, including amygdala and hippocampus (cluster-level correctedp= 0.002). For the latter three regions, BP was decreased in the right hemisphere. These results agree with the hypothesis that early maternal deprivation affects the development of the serotonergic system and suggest that decreased serotonergic innervations in the critical brain regions may explain some of the behavioral and biochemical abnormalities in PR monkeys.
- 26 April 2006
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 26 (17) , 4638-4643
Open AccessEffects of Early Life Stress on [11C]DASB Positron Emission Tomography Imaging of Serotonin Transporters in Adolescent Peer- and Mother-Reared Rhesus Monkeys
Peer-reared (PR) rhesus monkeys with early maternal separation later exhibit aggressiveness, impaired impulse control, alcohol abuse, and low CSF 5-hydroxyindoleacetic acid. This study compared regional brain serotonin transporter (SERT) binding between nine PR and seven mother-reared rhesus monkeys with [11C]DASB positron emission tomography (PET) imaging. Parametric images of binding potential (BP) (which is proportional toBmax/KD, in whichBmaxis transporter density andKDis dissociation constant) and relative blood flow (R1) were generated by the two-parameter multilinear reference tissue model.R1images were used for coregistration and normalization of PET parametric data to the magnetic resonance imaging template space. Group BP differences were analyzed voxelwise by Student'sttest in SPM2. Region of interest-based parameter values were also calculated to obtain the magnitude of regional BP differences between the two groups. For the PR group, SERT BP was decreased by 10–23% across a range of brain areas consisting of the raphe, thalamus, hypothalamus, caudate and putamen, globus pallidum, anterior cingulate gyrus, and medial temporal regions, including amygdala and hippocampus (cluster-level correctedp= 0.002). For the latter three regions, BP was decreased in the right hemisphere. These results agree with the hypothesis that early maternal deprivation affects the development of the serotonergic system and suggest that decreased serotonergic innervations in the critical brain regions may explain some of the behavioral and biochemical abnormalities in PR monkeys.
- 1 September 2004
- Vol. 45 (9) , 1555-9
Biodistribution and radiation dosimetry of the serotonin transporter ligand 11C-DASB determined from human whole-body PET.
11C-Labeled 3-amino-4-(2-dimethylaminomethylphenylsulfanyl)-benzonitrile (DASB) is a selective radioligand for the in vivo quantitation of serotonin transporters (SERTs) using PET. The goal of this study was to provide dosimetry estimates for 11C-DASB based on human whole-body PET. Dynamic whole-body PET scans were acquired for 7 subjects after the injection of 669 +/- 97 MBq (18.1 +/- 2.6 mCi) of 11C-DASB. The acquisition for each subject was obtained at 14 time points for a total of 115 min after injection of the radioligand. Regions of interest were placed over compressed planar images of source organs that could be visually identified to generate time-activity curves. Radiation burden to the body was calculated from residence times of these source organs using the MIRDOSE3.1 program. The organs with high radiation burden included the lungs, urinary bladder wall, kidneys, gallbladder wall, heart wall, spleen, and liver. The activity peaked within 10 min after the injection of 11C-DASB for all these organs except two--the excretory organs gallbladder and urinary bladder wall, which had peak activities at 32 and 22 min, respectively. Monoexponential fitting of activity overlying the urinary bladder suggested that approximately 12% of activity was excreted via the urine. Simulations in which the urinary voiding interval was decreased from 4.8 to 0.6 h produced only modest effects on the dose to the urinary bladder wall. With a 2.4-h voiding interval, the calculated effective dose was 6.98 microGy/MBq (25.8 mrem/mCi). The estimated radiation burden of 11C-DASB is relatively modest and would allow multiple PET examinations of the same research subject per year.
- 1 September 2004
- Vol. 45 (9) , 1555-9
Biodistribution and radiation dosimetry of the serotonin transporter ligand 11C-DASB determined from human whole-body PET.
11C-Labeled 3-amino-4-(2-dimethylaminomethylphenylsulfanyl)-benzonitrile (DASB) is a selective radioligand for the in vivo quantitation of serotonin transporters (SERTs) using PET. The goal of this study was to provide dosimetry estimates for 11C-DASB based on human whole-body PET. Dynamic whole-body PET scans were acquired for 7 subjects after the injection of 669 +/- 97 MBq (18.1 +/- 2.6 mCi) of 11C-DASB. The acquisition for each subject was obtained at 14 time points for a total of 115 min after injection of the radioligand. Regions of interest were placed over compressed planar images of source organs that could be visually identified to generate time-activity curves. Radiation burden to the body was calculated from residence times of these source organs using the MIRDOSE3.1 program. The organs with high radiation burden included the lungs, urinary bladder wall, kidneys, gallbladder wall, heart wall, spleen, and liver. The activity peaked within 10 min after the injection of 11C-DASB for all these organs except two--the excretory organs gallbladder and urinary bladder wall, which had peak activities at 32 and 22 min, respectively. Monoexponential fitting of activity overlying the urinary bladder suggested that approximately 12% of activity was excreted via the urine. Simulations in which the urinary voiding interval was decreased from 4.8 to 0.6 h produced only modest effects on the dose to the urinary bladder wall. With a 2.4-h voiding interval, the calculated effective dose was 6.98 microGy/MBq (25.8 mrem/mCi). The estimated radiation burden of 11C-DASB is relatively modest and would allow multiple PET examinations of the same research subject per year.
- 1 August 2004
- Vol. 45 (8) , 1398-405
Absolute quantification of regional cerebral glucose utilization in mice by 18F-FDG small animal PET scanning and 2-14C-DG autoradiography.
The purpose of this study was to evaluate the feasibility of absolute quantification of regional cerebral glucose utilization (rCMR(glc)) in mice by use of (18)F-FDG and a small animal PET scanner. rCMR(glc) determined with (18)F-FDG PET was compared with values determined simultaneously by the autoradiographic 2-(14)C-DG method. In addition, we compared the rCMR(glc) values under isoflurane, ketamine and xylazine anesthesia, and awake states. Immediately after injection of (18)F-FDG and 2-(14)C-DG into mice, timed arterial samples were drawn over 45 min to determine the time courses of (18)F-FDG and 2-(14)C-DG. Animals were euthanized at 45 min and their brain was imaged with the PET scanner. The brains were then processed for 2-(14)C-DG autoradiography. Regions of interest were manually placed over cortical regions on corresponding coronal (18)F-FDG PET and 2-(14)C-DG autoradiographic images. rCMR(glc) values were calculated for both tracers by the autoradiographic 2-(14)C-DG method with modifications for the different rate and lumped constants for the 2 tracers. Average rCMR(glc) values in cerebral cortex with (18)F-FDG PET under normoglycemic conditions (isoflurane and awake) were generally lower (by 8.3%) but strongly correlated with those of 2-(14)C-DG (r(2) = 0.95). On the other hand, under hyperglycemic conditions (ketamine/xylazine) average cortical rCMR(glc) values with (18)F-FDG PET were higher (by 17.3%) than those with 2-(14)C-DG. Values for rCMR(glc) and uptake (percentage injected dose per gram [%ID/g]) with (18)F-FDG PET were significantly lower under both isoflurane and ketamine/xylazine anesthesia than in the awake mice. However, the reductions of rCMR(glc) were markedly greater under isoflurane (by 57%) than under ketamine and xylazine (by 19%), whereas more marked reductions of %ID/g were observed with ketamine/xylazine (by 54%) than with isoflurane (by 37%). These reverse differences between isoflurane and ketamine/xylazine may be due to competitive effect of (18)F-FDG and glucose uptake to the brain under hyperglycemia. We were able to obtain accurate absolute quantification of rCMR(glc) with mouse (18)F-FDG PET imaging as confirmed by concurrent use of the autoradiographic 2-(14)C-DG method. Underestimation of rCMR(glc) by (18)F-FDG in normoglycemic conditions may be due to partial-volume effects. Computation of rCMR(glc) from (18)F-FDG data in hyperglycemic animals may require, however, alternative rate and lumped constants for (18)F-FDG.
- 1 August 2004
- Vol. 45 (8) , 1398-405
Absolute quantification of regional cerebral glucose utilization in mice by 18F-FDG small animal PET scanning and 2-14C-DG autoradiography.
The purpose of this study was to evaluate the feasibility of absolute quantification of regional cerebral glucose utilization (rCMR(glc)) in mice by use of (18)F-FDG and a small animal PET scanner. rCMR(glc) determined with (18)F-FDG PET was compared with values determined simultaneously by the autoradiographic 2-(14)C-DG method. In addition, we compared the rCMR(glc) values under isoflurane, ketamine and xylazine anesthesia, and awake states. Immediately after injection of (18)F-FDG and 2-(14)C-DG into mice, timed arterial samples were drawn over 45 min to determine the time courses of (18)F-FDG and 2-(14)C-DG. Animals were euthanized at 45 min and their brain was imaged with the PET scanner. The brains were then processed for 2-(14)C-DG autoradiography. Regions of interest were manually placed over cortical regions on corresponding coronal (18)F-FDG PET and 2-(14)C-DG autoradiographic images. rCMR(glc) values were calculated for both tracers by the autoradiographic 2-(14)C-DG method with modifications for the different rate and lumped constants for the 2 tracers. Average rCMR(glc) values in cerebral cortex with (18)F-FDG PET under normoglycemic conditions (isoflurane and awake) were generally lower (by 8.3%) but strongly correlated with those of 2-(14)C-DG (r(2) = 0.95). On the other hand, under hyperglycemic conditions (ketamine/xylazine) average cortical rCMR(glc) values with (18)F-FDG PET were higher (by 17.3%) than those with 2-(14)C-DG. Values for rCMR(glc) and uptake (percentage injected dose per gram [%ID/g]) with (18)F-FDG PET were significantly lower under both isoflurane and ketamine/xylazine anesthesia than in the awake mice. However, the reductions of rCMR(glc) were markedly greater under isoflurane (by 57%) than under ketamine and xylazine (by 19%), whereas more marked reductions of %ID/g were observed with ketamine/xylazine (by 54%) than with isoflurane (by 37%). These reverse differences between isoflurane and ketamine/xylazine may be due to competitive effect of (18)F-FDG and glucose uptake to the brain under hyperglycemia. We were able to obtain accurate absolute quantification of rCMR(glc) with mouse (18)F-FDG PET imaging as confirmed by concurrent use of the autoradiographic 2-(14)C-DG method. Underestimation of rCMR(glc) by (18)F-FDG in normoglycemic conditions may be due to partial-volume effects. Computation of rCMR(glc) from (18)F-FDG data in hyperglycemic animals may require, however, alternative rate and lumped constants for (18)F-FDG.
- 1 September 2003
- Vol. 31 (3) , 157-60
Evaluation of 2 scatter correction methods using a striatal phantom for quantitative brain SPECT.
Scatter correction is an important factor in quantitative SPECT. In this study, we evaluated 2 methods of scatter correction for brain SPECT. The first is based on thresholding the energy spectrum (ES), and the second is based on a modification of the transmission-dependent convolution subtraction (TDCS) method. SPECT imaging of a skull striatal phantom was performed using a triple-head camera with and without scatter correction. The striatal compartments were filled with (123)I, and the brain shell cavity (background) was filled with varying concentrations of (123)I to obtain striatal-to-background ratios of 2, 5, 10, 15, 20, and 25 to 1, respectively, which were considered to be the expected ratios. SPECT-measured ratios of striatal-to-background counts were determined with scatter correction (both ES and TDCS methods) and without scatter correction and were then compared with the expected ratios. Without scatter correction, measured striatal-to-background ratios were underestimated by an average of 41.7%, compared with the expected ratios. The ES method of scatter correction underestimated the striatal-to-background ratios by an average of 27.4%, a significant improvement (P < 0.04) over those without scatter correction. With the TDCS method of scatter correction, the ratios were underestimated by only 3.3% (P < 0.03). TDCS ratios were significantly (P < 0.04) higher than ES ratios and were nearly identical to the expected ratios. These results suggest that scatter correction significantly improves the striatal-to-background ratios. The TDCS method appears to correct scatter more effectively than does the ES method for the striatal phantom, thus providing more accurate quantification.
- 1 September 2003
- Vol. 31 (3) , 157-60
Evaluation of 2 scatter correction methods using a striatal phantom for quantitative brain SPECT.
Scatter correction is an important factor in quantitative SPECT. In this study, we evaluated 2 methods of scatter correction for brain SPECT. The first is based on thresholding the energy spectrum (ES), and the second is based on a modification of the transmission-dependent convolution subtraction (TDCS) method. SPECT imaging of a skull striatal phantom was performed using a triple-head camera with and without scatter correction. The striatal compartments were filled with (123)I, and the brain shell cavity (background) was filled with varying concentrations of (123)I to obtain striatal-to-background ratios of 2, 5, 10, 15, 20, and 25 to 1, respectively, which were considered to be the expected ratios. SPECT-measured ratios of striatal-to-background counts were determined with scatter correction (both ES and TDCS methods) and without scatter correction and were then compared with the expected ratios. Without scatter correction, measured striatal-to-background ratios were underestimated by an average of 41.7%, compared with the expected ratios. The ES method of scatter correction underestimated the striatal-to-background ratios by an average of 27.4%, a significant improvement (P < 0.04) over those without scatter correction. With the TDCS method of scatter correction, the ratios were underestimated by only 3.3% (P < 0.03). TDCS ratios were significantly (P < 0.04) higher than ES ratios and were nearly identical to the expected ratios. These results suggest that scatter correction significantly improves the striatal-to-background ratios. The TDCS method appears to correct scatter more effectively than does the ES method for the striatal phantom, thus providing more accurate quantification.