Marvin C. Ziskin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marvin C. Ziskin has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
S.I. Alekseev
Center for Biomedical Physics, Temple University Medical School, Philadelphia, Pennsylvania
4 shared publications- A.A. Radzievsky
Center for Biomedical Physics, Temple University Medical School, Philadelphia, Pennsylvania 19140, USA
1 shared publication I. Szabo
Center for Biomedical Physics, Temple University Medical School, Philadelphia, Pennsylvania
1 shared publicationO.V. Gordiienko
Center for Biomedical Physics, Temple University Medical School, Philadelphia, Pennsylvania
1 shared publicationS I Alekseev
Institute of Cell Biophysics of Russian Academy of Sciences, Pushchino, Moscow Region
1 shared publication- Stanislav I. Alekseev
Center for Biomedical Physics, Temple University Medical School, Philadelphia, PA 19140, USA
1 shared publication
Latest Publications
- 12 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 56 (10) , 2380-2388
Millimeter-Wave Absorption by Cutaneous Blood Vessels: A Computational Study
The aims of the present study were to calculate the specific absorption rate (SAR) and EMield distributions inside cutaneous blood vessels and in surrounding tissues (dermis and fat) depending on the frequency of millimeter wave exposure. Most calculations were performed using the finite-difference time-domain (FDTD) technique. A rectangular block of homogeneous or multilayer tissue with blood vessels located in the center of the block was used as the basic geometry. We found that the SAR reached its maximal value in a long blood vessel oriented parallel to the E-field. It exceeded the SAR in the surrounding dermis by 40%- 42% at 42.25 GHz. However, in the same blood vessel oriented perpendicularly to the E-field, the SAR was lower than that of the surrounding dermis. Absorption of millimeter waves in a cutaneous blood vessel was higher at 61.22 GHz than at 42.25 GHz. The SAR distribution in a blood vessel was nearly uniform. Because of the small sizes of cutaneous blood vessels relative to the wavelength, the SAR distributions in these blood vessels can be calculated by using quasi-static theory.
- 12 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 56 (10) , 2380-2388
Millimeter-Wave Absorption by Cutaneous Blood Vessels: A Computational Study
The aims of the present study were to calculate the specific absorption rate (SAR) and EMield distributions inside cutaneous blood vessels and in surrounding tissues (dermis and fat) depending on the frequency of millimeter wave exposure. Most calculations were performed using the finite-difference time-domain (FDTD) technique. A rectangular block of homogeneous or multilayer tissue with blood vessels located in the center of the block was used as the basic geometry. We found that the SAR reached its maximal value in a long blood vessel oriented parallel to the E-field. It exceeded the SAR in the surrounding dermis by 40%- 42% at 42.25 GHz. However, in the same blood vessel oriented perpendicularly to the E-field, the SAR was lower than that of the surrounding dermis. Absorption of millimeter waves in a cutaneous blood vessel was higher at 61.22 GHz than at 42.25 GHz. The SAR distribution in a blood vessel was nearly uniform. Because of the small sizes of cutaneous blood vessels relative to the wavelength, the SAR distributions in these blood vessels can be calculated by using quasi-static theory.
- 3 August 2004
- Published by Wiley in Bioelectromagnetics
- Vol. 25 (6) , 466-473
Millimeter wave‐induced suppression of B16 F10 melanoma growth in mice: Involvement of endogenous opioids
Millimeter wave treatment (MMWT) is widely used in Eastern European countries, but is virtually unknown in Western medicine. Among reported MMWT effects is suppression of tumor growth. The main aim of the present “blind” and dosimetrically controlled experiments was to evaluate quantitatively the ability of MMWT to influence tumor growth and to assess whether endogenous opioids are involved. The murine experimental model of B16 F10 melanoma subcutaneous growth was used. MMWT characteristics were: frequency, 61.22 GHz; average incident power density, 13.3 × 10−3 W/cm2; single exposure duration, 15 min; and exposure area, nose. Naloxone (1 mg/kg, intraperitoneally, 30 min prior to MMWT) was used as a nonspecific blocker of opioid receptors. Five daily MMW exposures, if applied starting at the fifth day following B16 melanoma cell injection, suppressed subcutaneous tumor growth. Pretreatment with naloxone completely abolished the MMWT-induced suppression of melanoma growth. The same course of 5 MMW treatments, if started on day 1 or day 10 following tumor inoculations, was ineffective. We concluded that MMWT has an anticancer therapeutic potential and that endogenous opioids are involved in MMWT-induced suppression of melanoma growth in mice. However, appropriate indications and contraindications have to be developed experimentally before recommending MMWT for clinical usage. Bioelectromagnetics 25:466–473, 2004.
- 3 August 2004
- Published by Wiley in Bioelectromagnetics
- Vol. 25 (6) , 466-473
Millimeter wave‐induced suppression of B16 F10 melanoma growth in mice: Involvement of endogenous opioids
Millimeter wave treatment (MMWT) is widely used in Eastern European countries, but is virtually unknown in Western medicine. Among reported MMWT effects is suppression of tumor growth. The main aim of the present “blind” and dosimetrically controlled experiments was to evaluate quantitatively the ability of MMWT to influence tumor growth and to assess whether endogenous opioids are involved. The murine experimental model of B16 F10 melanoma subcutaneous growth was used. MMWT characteristics were: frequency, 61.22 GHz; average incident power density, 13.3 × 10−3 W/cm2; single exposure duration, 15 min; and exposure area, nose. Naloxone (1 mg/kg, intraperitoneally, 30 min prior to MMWT) was used as a nonspecific blocker of opioid receptors. Five daily MMW exposures, if applied starting at the fifth day following B16 melanoma cell injection, suppressed subcutaneous tumor growth. Pretreatment with naloxone completely abolished the MMWT-induced suppression of melanoma growth. The same course of 5 MMW treatments, if started on day 1 or day 10 following tumor inoculations, was ineffective. We concluded that MMWT has an anticancer therapeutic potential and that endogenous opioids are involved in MMWT-induced suppression of melanoma growth in mice. However, appropriate indications and contraindications have to be developed experimentally before recommending MMWT for clinical usage. Bioelectromagnetics 25:466–473, 2004.
- 1 July 2001
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 27 (7) , 875-876
Ultrasound and the developing central nervous system
- 1 July 2001
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 27 (7) , 875-876
Ultrasound and the developing central nervous system
- 5 April 2001
- Published by Wiley in Bioelectromagnetics
- Vol. 22 (4) , 288-291
Millimeter wave power density in aqueous biological samples.
- 5 April 2001
- Published by Wiley in Bioelectromagnetics
- Vol. 22 (4) , 288-291
Millimeter wave power density in aqueous biological samples.
- 27 April 2000
- Published by Wiley in Bioelectromagnetics
- Vol. 21 (4) , 264-271
Reflection and absorption of millimeter waves by thin absorbing films
Reflection, transmission, and absorption of mm‐waves by thin absorbing films were determined at two therapeutic frequencies: 42.25 and 53.57 GHz. Thin filter strips saturated with distilled water or an alcohol–water solution were used as absorbing samples of different thicknesses. The dependence of the power reflection coefficient R(d) on film thickness (d) was not monotonic. R(d) passed through a pronounced maximum before reaching its steady‐state level [R(∞)]. Similarly, absorption, A(d), passed two maximums with one minimum between them, before reaching its steady‐state level [A(∞)]. At 42.25 GHz, A(d) was compared with absorption in a semi‐infinite water medium at a depth d. When d < 0.3 mm, absorption by the film increased: at d = 0.1 mm the absorption ratio for the thin layer sample and the semi‐infinite medium was 3.2, while at d = 0.05 mm it increased up to 5.8. Calculations based on Fresnel equations for flat thin layers adequately described the dependence of the reflection, transmission, and absorption on d and allowed the determination of the refractive index (n), dielectric constant (ε), and penetration depth (δ) of the absorbing medium for various frequencies. For water samples, ε was found to be 12.4−19.3j, δ = 0.49 mm at 42.25 GHz, and ε = 9.0−19.5j, δ = 0.36 mm at 53.57 GHz. The calculated power density distribution within the film was strongly dependent on d. The measurements and calculations have shown that the reflection and absorption of mm‐waves by thin absorbing layers can significantly differ from the reflection and absorption in similar semi‐infinite media. The difference in reflection, absorption, and power density distribution in films, as compared to semi‐infinite media, are caused by multiple internal reflections from the film boundaries. That is why, when using thin phantoms and thin biological samples, the specifics of the interaction of mm‐waves with thin films should be taken into account. Bioelectromagnetics 21:264–271, 2000.
- 27 April 2000
- Published by Wiley in Bioelectromagnetics
- Vol. 21 (4) , 264-271
Reflection and absorption of millimeter waves by thin absorbing films
Reflection, transmission, and absorption of mm‐waves by thin absorbing films were determined at two therapeutic frequencies: 42.25 and 53.57 GHz. Thin filter strips saturated with distilled water or an alcohol–water solution were used as absorbing samples of different thicknesses. The dependence of the power reflection coefficient R(d) on film thickness (d) was not monotonic. R(d) passed through a pronounced maximum before reaching its steady‐state level [R(∞)]. Similarly, absorption, A(d), passed two maximums with one minimum between them, before reaching its steady‐state level [A(∞)]. At 42.25 GHz, A(d) was compared with absorption in a semi‐infinite water medium at a depth d. When d < 0.3 mm, absorption by the film increased: at d = 0.1 mm the absorption ratio for the thin layer sample and the semi‐infinite medium was 3.2, while at d = 0.05 mm it increased up to 5.8. Calculations based on Fresnel equations for flat thin layers adequately described the dependence of the reflection, transmission, and absorption on d and allowed the determination of the refractive index (n), dielectric constant (ε), and penetration depth (δ) of the absorbing medium for various frequencies. For water samples, ε was found to be 12.4−19.3j, δ = 0.49 mm at 42.25 GHz, and ε = 9.0−19.5j, δ = 0.36 mm at 53.57 GHz. The calculated power density distribution within the film was strongly dependent on d. The measurements and calculations have shown that the reflection and absorption of mm‐waves by thin absorbing layers can significantly differ from the reflection and absorption in similar semi‐infinite media. The difference in reflection, absorption, and power density distribution in films, as compared to semi‐infinite media, are caused by multiple internal reflections from the film boundaries. That is why, when using thin phantoms and thin biological samples, the specifics of the interaction of mm‐waves with thin films should be taken into account. Bioelectromagnetics 21:264–271, 2000.
- 6 January 1999
- Published by Wiley in Bioelectromagnetics
- Vol. 20 (1) , 24-33
Effects of millimeter waves on ionic currents of Lymnaea neurons
- 6 January 1999
- Published by Wiley in Bioelectromagnetics
- Vol. 20 (1) , 24-33
Effects of millimeter waves on ionic currents of Lymnaea neurons
- 1 January 1999
- Vol. 20 (1) , 24-33
Effects of millimeter waves on ionic currents of Lymnaea neurons.
The effects of mm-waves 60.22-62.22 GHz and 75 GHz on A-type K+ currents and the effects of 61.22 GHz on Ca2+ currents of Lymnaea neurons were investigated using a whole-cell voltage-clamp technique. The open end of a rectangular waveguide covered with a thin Teflon film served as a radiator. Specific absorption rates at the waveguide outlet, inserted into physiological solution, were in the range of 0-2400 W/kg. Millimeter wave irradiation increased the peak amplitudes, activation rates, and inactivation rates of both ion currents. The changes in A-type K+ current were not dependent on the irradiation frequency. It was shown that the changes in the amplitudes and kinetics of both currents resulted from the temperature rise produced by irradiation. No additional effects of irradiation on A-type K+ current other than thermal were found when tested at the phase transition temperature or in the presence of ethanol. Ethanol reduced the thermal effect of irradiation. Millimeter waves had no effect on the steady-state activation and inactivation curves, suggesting that the membrane surface charge and binding of calcium ions to the membrane in the area of channel locations did not change.
- 1 January 1999
- Vol. 20 (1) , 24-33
Effects of millimeter waves on ionic currents of Lymnaea neurons.
The effects of mm-waves 60.22-62.22 GHz and 75 GHz on A-type K+ currents and the effects of 61.22 GHz on Ca2+ currents of Lymnaea neurons were investigated using a whole-cell voltage-clamp technique. The open end of a rectangular waveguide covered with a thin Teflon film served as a radiator. Specific absorption rates at the waveguide outlet, inserted into physiological solution, were in the range of 0-2400 W/kg. Millimeter wave irradiation increased the peak amplitudes, activation rates, and inactivation rates of both ion currents. The changes in A-type K+ current were not dependent on the irradiation frequency. It was shown that the changes in the amplitudes and kinetics of both currents resulted from the temperature rise produced by irradiation. No additional effects of irradiation on A-type K+ current other than thermal were found when tested at the phase transition temperature or in the presence of ethanol. Ethanol reduced the thermal effect of irradiation. Millimeter waves had no effect on the steady-state activation and inactivation curves, suggesting that the membrane surface charge and binding of calcium ions to the membrane in the area of channel locations did not change.