Markus Benk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Markus Benk has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Klaus Bergmann
Fraunhofer Institute for Laser Technology , Steinbachstrasse 15, D-52074 Aachen, Germany
2 shared publicationsDavid Schäfer
University of Applied Sciences Koblenz
1 shared publicationThomas Wilhein
University of Applied Sciences Koblenz
1 shared publication
Latest Publications
- 1 March 2009
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 80 (3) , 033113
Adaptive spatially resolving detector for the extreme ultraviolet with absolute measuring capability
A spatially resolving detector for the extreme ultraviolet (XUV) and soft x-ray spectral region is presented. Principle of operation is conversion of XUV radiation to visible light by a scintillator crystal. Luminescence is detected using charge coupled device camera and imaging optics. Single layer and multilayer coatings are applied to match the system to different spectral regions of interest. Field of view and spatial resolution can be adapted to the application. Calibration of the system enables to absolutely measure in-band radiation flux on the scintillator. The setup is designed for the characterization and optimization of XUV sources and XUV optical systems. Measurements, carried out to characterize the focus in a soft x-ray microscope, are presented as an application example.
- 1 March 2009
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 80 (3) , 033113
Adaptive spatially resolving detector for the extreme ultraviolet with absolute measuring capability
A spatially resolving detector for the extreme ultraviolet (XUV) and soft x-ray spectral region is presented. Principle of operation is conversion of XUV radiation to visible light by a scintillator crystal. Luminescence is detected using charge coupled device camera and imaging optics. Single layer and multilayer coatings are applied to match the system to different spectral regions of interest. Field of view and spatial resolution can be adapted to the application. Calibration of the system enables to absolutely measure in-band radiation flux on the scintillator. The setup is designed for the characterization and optimization of XUV sources and XUV optical systems. Measurements, carried out to characterize the focus in a soft x-ray microscope, are presented as an application example.
- 14 October 2008
- Published by Optica Publishing Group in Optics Letters
- Vol. 33 (20) , 2359-2361
Compact soft x-ray microscope using a gas-discharge light source
We report on a soft x-ray microscope using a gas-discharge plasma with pseudo spark-like electrode geometry as a light source. The source produces a radiant intensity of for the emission line of helium-like nitrogen. At a demonstrated repetition rate a brilliance of is obtained for the line. Ray-tracing simulations show that, employing an adequate grazing incidence collector, a photon flux of can be achieved with the current source. The applicability of the presented pinch plasma concept to soft x-ray microscopy is demonstrated in a proof-of-principle experiment.- 14 October 2008
- Published by Optica Publishing Group in Optics Letters
- Vol. 33 (20) , 2359-2361
Compact soft x-ray microscope using a gas-discharge light source
We report on a soft x-ray microscope using a gas-discharge plasma with pseudo spark-like electrode geometry as a light source. The source produces a radiant intensity of for the emission line of helium-like nitrogen. At a demonstrated repetition rate a brilliance of is obtained for the line. Ray-tracing simulations show that, employing an adequate grazing incidence collector, a photon flux of can be achieved with the current source. The applicability of the presented pinch plasma concept to soft x-ray microscopy is demonstrated in a proof-of-principle experiment.