Steven W. Sharpe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Steven W. Sharpe has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Robert L. Sams
Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352 (S.W.S., T.J.J., R.L.S.); and National Institute of Standards and Technology, Analytical Chemistry Division, 100 Bureau Drive, Stop 8393, Gaithersburg, Maryland 20899-8393 (P.M.C., G.C.R., P.A.J.)
3 shared publications- Thomas A. Blake
Pacific Northwest National Laboratory, P.O. Box 999, Mail Stop K4-13, Richland, WA 99352, USA
2 shared publications Timothy J. Johnson
Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352 (S.W.S., T.J.J., R.L.S.); and National Institute of Standards and Technology, Analytical Chemistry Division, 100 Bureau Drive, Stop 8393, Gaithersburg, Maryland 20899-8393 (P.M.C., G.C.R., P.A.J.)
2 shared publicationsBret D. Cannon
Pacific Northwest National Lab. (United States)
1 shared publicationGeorge C. Rhoderick
Pacific Northwest National Laboratory, P.O. Box 999, Richland, Washington 99352 (S.W.S., T.J.J., R.L.S.); and National Institute of Standards and Technology, Analytical Chemistry Division, 100 Bureau Drive, Stop 8393, Gaithersburg, Maryland 20899-8393 (P.M.C., G.C.R., P.A.J.)
1 shared publicationJames F. Kelly
Pacific Northwest National Lab. (United States)
1 shared publication
Latest Publications
- 16 December 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5585, 122-128
On the relative strengths of bacillus spore signatures in the terahertz (THz) versus the mid-infrared
We have recently extended our studies of the infrared signatures of Bacillus bacterial spores from the mid-infrared to the far-infrared (sometimes called the terahertz, THz) spectral domain. The ultimate goal is to use such signatures to distinguish different strains of spores from unknowns as well as from one another. Five different strains of Bacillus were prepared by culturing the spores, washing repeatedly in sterile water and drying them onto windows that are simultaneously transparent in both the mid- and far-infrared. The strains include B. globigii BG-01, B. thuringiensis subsp kurstaki ATCC 35866, B. subtilis ATCC 49760, B. subtilis ATCC 6051, and B. atrophaeus ATCC 49337. Using different combinations of hardware in the Fourier transform infrared (FTIR) spectrometer, essentially continuous spectral coverage was obtained from ~8 to 6,000 cm-1. Preliminary results indicate that any THz signatures are at least 25 times weaker (based on p-p noise) than the strongest mid-IR amide I bands near 1657 cm-1.
- 16 December 2004
- Published by SPIE-Intl Soc Optical Eng
- Vol. 5585, 122-128
On the relative strengths of bacillus spore signatures in the terahertz (THz) versus the mid-infrared
We have recently extended our studies of the infrared signatures of Bacillus bacterial spores from the mid-infrared to the far-infrared (sometimes called the terahertz, THz) spectral domain. The ultimate goal is to use such signatures to distinguish different strains of spores from unknowns as well as from one another. Five different strains of Bacillus were prepared by culturing the spores, washing repeatedly in sterile water and drying them onto windows that are simultaneously transparent in both the mid- and far-infrared. The strains include B. globigii BG-01, B. thuringiensis subsp kurstaki ATCC 35866, B. subtilis ATCC 49760, B. subtilis ATCC 6051, and B. atrophaeus ATCC 49337. Using different combinations of hardware in the Fourier transform infrared (FTIR) spectrometer, essentially continuous spectral coverage was obtained from ~8 to 6,000 cm-1. Preliminary results indicate that any THz signatures are at least 25 times weaker (based on p-p noise) than the strongest mid-IR amide I bands near 1657 cm-1.
- Top Cited Papers
- 1 December 2004
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 58 (12) , 1452-1461
Gas-Phase Databases for Quantitative Infrared Spectroscopy
The National Institute of Standards and Technology (NIST) and the Pacific Northwest National Laboratory (PNNL) are each creating quantitative databases containing the vapor-phase infrared spectra of pure chemicals. The digital databases have been created with both laboratory and remote-sensing applications in mind. A spectral resolution of ≈0.1 cm −1 was selected to avoid degrading sharp spectral features, while also realizing that atmospheric broadening typically limits line widths to 0.1 cm −1 . Calculated positional (wavenumber, cm −1 ) uncertainty is ≤0.005 cm −1 , while the 1σ statistical uncertainty in absorbance values is <2% for most compounds. The latter was achieved by measuring multiple (typically ≥9) path length–concentration burdens and fitting a weighted Beer's law plot to each wavenumber channel. The two databases include different classes of compounds and were compared using 12 samples. Though these 12 samples span a range of polarities, absorption strengths, and vapor pressures, the data agree to within experimental uncertainties with only one exception.
- 1 December 2004
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 58 (12) , 1452-1461
Top Cited PapersGas-Phase Databases for Quantitative Infrared Spectroscopy
The National Institute of Standards and Technology (NIST) and the Pacific Northwest National Laboratory (PNNL) are each creating quantitative databases containing the vapor-phase infrared spectra of pure chemicals. The digital databases have been created with both laboratory and remote-sensing applications in mind. A spectral resolution of ≈0.1 cm −1 was selected to avoid degrading sharp spectral features, while also realizing that atmospheric broadening typically limits line widths to 0.1 cm −1 . Calculated positional (wavenumber, cm −1 ) uncertainty is ≤0.005 cm −1 , while the 1σ statistical uncertainty in absorbance values is <2% for most compounds. The latter was achieved by measuring multiple (typically ≥9) path length–concentration burdens and fitting a weighted Beer's law plot to each wavenumber channel. The two databases include different classes of compounds and were compared using 12 samples. Though these 12 samples span a range of polarities, absorption strengths, and vapor pressures, the data agree to within experimental uncertainties with only one exception.
- 20 May 2002
- Published by Optica Publishing Group in Applied Optics
- Vol. 41 (15) , 2831-2839
Removing aperture-induced artifacts from fourier transform infrared intensity values
Two Fourier transform infrared intensity artifacts have been observed at moderately high (0.1 cm-1) spectral resolution: Light reflected off the aperture was double modulated by the interferometer, producing a 2f alias, and the warm (≈310 K) annulus of the aperture seen by a cooled detector resulted in distorted line shapes and anomalous intensities in the fingerprint region. Although the second artifact has been alluded to previously, we report corrections to remove both of these anomalies and to demonstrate the efficacy of these corrections. Prior to correction, integrated-band intensities were found to be in error by up to 12%.
- 20 May 2002
- Published by Optica Publishing Group in Applied Optics
- Vol. 41 (15) , 2831-2839
Removing aperture-induced artifacts from fourier transform infrared intensity values
Two Fourier transform infrared intensity artifacts have been observed at moderately high (0.1 cm-1) spectral resolution: Light reflected off the aperture was double modulated by the interferometer, producing a 2f alias, and the warm (≈310 K) annulus of the aperture seen by a cooled detector resulted in distorted line shapes and anomalous intensities in the fingerprint region. Although the second artifact has been alluded to previously, we report corrections to remove both of these anomalies and to demonstrate the efficacy of these corrections. Prior to correction, integrated-band intensities were found to be in error by up to 12%.
- 8 July 2000
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 113 (2) , 707-718
Rotationally resolved spectroscopy of a librational fundamental band of hydrogen fluoride tetramer
- 8 July 2000
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 113 (2) , 707-718
Rotationally resolved spectroscopy of a librational fundamental band of hydrogen fluoride tetramer
- 31 October 1997
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3127, 64-103
Applications of wideband FM spectroscopy to environmental and industrial process monitoring
Progress in understanding and developing methodologies to do low frequency, wideband FM-coding on a variety of laser sources is presented. Several practical FM-coding formats have been studied and compared for use with large, 'slow' IR detectors. The objective of this work is to establish practical methods of doing long baseline absorbance measurements in the lower troposphere that could be degraded by large integrated effects of optical turbulence. A comparative study of producing high index modulation on laser diodes and other practical laser sources is presented, along with numerical simulations and experimental result of detected signal strength. These results are presented with the intent of illustrating useful laser sources and FM- coding schemes that could allow effective detection of trace atmospherically broadened absorbance signatures. Results of field measurement will be discussed in order to suggest further improvement for this technique. Signal-to-noise issues and effects of phase distortion will be outlined with the view of suggesting correct optimization of laser transmitter and detector/preamp subsystems for these types of FM signal recovery. Finally, efforts at developing thermo-optically stable external electro-optic modulators will also be discussed.
- 31 October 1997
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3127, 64-103
Applications of wideband FM spectroscopy to environmental and industrial process monitoring
Progress in understanding and developing methodologies to do low frequency, wideband FM-coding on a variety of laser sources is presented. Several practical FM-coding formats have been studied and compared for use with large, 'slow' IR detectors. The objective of this work is to establish practical methods of doing long baseline absorbance measurements in the lower troposphere that could be degraded by large integrated effects of optical turbulence. A comparative study of producing high index modulation on laser diodes and other practical laser sources is presented, along with numerical simulations and experimental result of detected signal strength. These results are presented with the intent of illustrating useful laser sources and FM- coding schemes that could allow effective detection of trace atmospherically broadened absorbance signatures. Results of field measurement will be discussed in order to suggest further improvement for this technique. Signal-to-noise issues and effects of phase distortion will be outlined with the view of suggesting correct optimization of laser transmitter and detector/preamp subsystems for these types of FM signal recovery. Finally, efforts at developing thermo-optically stable external electro-optic modulators will also be discussed.