CSCraig F. Smith

Craig F. Smith

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Craig F. Smith has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Advanced Multilayer Composite Heavy-Oxide Scintillator Detectors for High-Efficiency Fast Neutron Detection

    by Volodymyr D. Ryzhikov, Sergei V. Naydenov, Thierry Pochet, Gennadiy M. Onyshchenko, Leonid A. Piven, Craig F. Smith

    We have developed and evaluated a new approach to fast neutron and neutron-gamma detection based on large-area multilayer composite heterogeneous detection media consisting of dispersed granules of small-crystalline scintillators contained in a transparent organic (plastic) matrix. Layers of the composite material are alternated with layers of transparent plastic scintillator material serving as light guides. The resulting detection medium . designated as ZEBRA . serves as both an active neutron converter and a detection scintillator which is designed to detect both neutrons and gamma-quanta. The composite layers of the ZEBRA detector consist of small heavy-oxide scintillators in the form of granules of crystalline ZWO, BGO, GSO(Ce) and other materials. We have produced and tested the ZEBRA detector of sizes 100 mm×100 mm×41 mm, and determined that they have very high efficiency of fast neutron detection (up to 49% or greater), comparable to that which can be achieved by large sized heavy-oxide single crystals of about Ø40×80 cm3 volume. We have also studied the sensitivity variation to fast neutron detection by using different types of multilayer ZEBRA detectors of 100 cm2 surface area and 41 mm thickness (with a detector weight of about 1 kg) and found it to be comparable to the sensitivity of a 3He-detector representing a total cross-section of about 2000 Cm2 (with a weight of detector, including its plastic moderator, of about 120 kg). The measured count rate in response to a fast neutron source of 252Cf at 2 m for the ZEBRA-GSO(Ce) detector of size 100 mm×100 mm×41 mm was 2.84 cps per nanogram of 252Cf isotope, and this count rate can be doubled by increasing the detector height (and area) up to 200 mm×100 mm. In summary, the ZEBRA detectors represent a new type of high efficiency and low cost large-area solid-state neutron detector that can be used for stationary neutron/gamma portals. They may represent an interesting alternative to expensive, bulky gas counters based on 3He or 10B neutron detection technologies.


  • Professional and household dosimeters for UV biologically active ranges of solar radiation on the basis of ZnSe semiconductor-metal nanostructures

    by Volodymyr D. Ryzhikov, Gennadiy M. Onyshchenko, Craig F. Smith, Oleksandr D. Opolonin, Olena K. Lysetska, Leonid A. Piven', Igor M. Zenya, Olexiy V. Volkov, Evgeniy F. Voronkin, Sergey N. Galkin, et al.

    Development is reported of a small-sized ultraviolet (UV) radiometer designed for measurements of energy characteristics of UV radiation - energy illuminance and energy exposure. Main characteristics are considered of nZnSe(O, Te)/Ni Schottky structures created for the developed UV radiometer and used as UV sensors. Characteristics are presented of optical glass filters and interference light filters designed for separation of different biologically relevant UV spectral regions.


  • Radiation Detectors Scintillator-Photodiode on the Base of A2B6 Crystals for Application in Homeland Security and Medical Equipment

    by B.V. Grinyov, V.D. Ryzhikov, S.V. Naydenov, C.F. Smith, A.D. Opolonin, E.K. Lisetskaya, N.A. Shumeiko, N.L. Kurna, G.M. Onischenko, S.E. Tretyak, et al.

    We have studied comparative parameters of different scintillators: CsI(Tl), CdWO 4 , ZnSe(Te), ZnSe(Te,O) for dual-energy radiography applications. Detectors of the scintillator-photodiode type were obtained on the basis of CsI(Tl), CdWO 4 and ZnSe(Te) crystals, and their comparative study was carried out, aiming at their use in X-ray multi-energy tomography. Because of their low afterglow level (10 ppm after 10 ms), CWO and ZnSe crystals are preferable for this application. Our experiments have demonstrated a possibility for significant distinction between explosives and safe organics, so as between soft and bone tissues. Direct image reconstruction of biological objects (bones) and customs control objects (bags with dangerous items and substances) was obtained by the used method of dual-energy radiography. Theory predicts that, provided the energy selectivity of the detection circuit is improved, separate detection of substances with difference of 5-10% in density and effective atomic number can be possible.