C Heusser
C Heusser has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Christine Neumann
1 shared publicationJ Bews
1 shared publicationJ Ménard
1 shared publicationJohn P.A. Bews
1 shared publicationKarl-Heinz Enssle
1 shared publicationKatrin Wagner
1 shared publication
Latest Publications
- 1 August 1998
- Published by Elsevier in Journal of Immunological Methods
- Vol. 217 (1-2) , 41-50
Detection of and discrimination between total and free human interleukin-4 and free soluble interleukin-4 receptor by ELISA
- 1 August 1998
- Published by Elsevier in Journal of Immunological Methods
- Vol. 217 (1-2) , 41-50
Detection of and discrimination between total and free human interleukin-4 and free soluble interleukin-4 receptor by ELISA
- 1 December 1997
- Published by Elsevier in Current Opinion in Immunology
- Vol. 9 (6) , 805-813
Therapeutic potential of anti-IgE antibodies
- 1 December 1997
- Published by Elsevier in Current Opinion in Immunology
- Vol. 9 (6) , 805-813
Therapeutic potential of anti-IgE antibodies
- 1 December 1984
- Vol. 2 (3) , S275-8
A multirange ELISA for the measurement of plasma renin in humans and primates.
A sensitive solid phase enzyme-linked immunosorbent assay (ELISA) has been developed using two anti-human renin monoclonal antibodies, which were shown to bind both human as well as primate renin at two different epitopic sites. One monoclonal antibody (3-36-16) was used to coat each well of a 96 well microtitre plate in which renin, contained in 5 to 20 ul of plasma, was allowed to react. Plates were then incubated with the gamma globulin (gamma G) fraction of a rabbit anti-human renin serum followed by development with sheetp anti-rabbit gamma G conjugated to alkaline phosphatase. Quantification was carried out by the addition of the alkaline phosphatase substrate, p-nitrophenylphosphate, which produced a colorimetric reaction. The sensitivity of the assay is 25 pg ml-1. The method recognises both active and inactive renin from plasma, kidney, amniotic fluid and chorionic cells. Plasma renin can be measured within 6 hours when values are greater then 150 pg ml-1 or within 24 hours when plasma values are less than 150 pg ml-1. The ELISA has already been used to measure total immunoreactive renin in plasma obtained from patients with several forms of hypertension. The values ranged from 25 pg ml-1 in patients with primary aldosteronism to as large as 60 ng ml-1 in a patient with a renin-secreting tumour.(ABSTRACT TRUNCATED AT 250 WORDS)
- 1 December 1984
- Vol. 2 (3) , S275-8
A multirange ELISA for the measurement of plasma renin in humans and primates.
A sensitive solid phase enzyme-linked immunosorbent assay (ELISA) has been developed using two anti-human renin monoclonal antibodies, which were shown to bind both human as well as primate renin at two different epitopic sites. One monoclonal antibody (3-36-16) was used to coat each well of a 96 well microtitre plate in which renin, contained in 5 to 20 ul of plasma, was allowed to react. Plates were then incubated with the gamma globulin (gamma G) fraction of a rabbit anti-human renin serum followed by development with sheetp anti-rabbit gamma G conjugated to alkaline phosphatase. Quantification was carried out by the addition of the alkaline phosphatase substrate, p-nitrophenylphosphate, which produced a colorimetric reaction. The sensitivity of the assay is 25 pg ml-1. The method recognises both active and inactive renin from plasma, kidney, amniotic fluid and chorionic cells. Plasma renin can be measured within 6 hours when values are greater then 150 pg ml-1 or within 24 hours when plasma values are less than 150 pg ml-1. The ELISA has already been used to measure total immunoreactive renin in plasma obtained from patients with several forms of hypertension. The values ranged from 25 pg ml-1 in patients with primary aldosteronism to as large as 60 ng ml-1 in a patient with a renin-secreting tumour.(ABSTRACT TRUNCATED AT 250 WORDS)