Andreas Lemke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Andreas Lemke has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Bram Stieltjes
3 shared publicationsDirk Simon
German Cancer Research Center, Software Development for Integrated Therapy and Diagnostics, Heidelberg, Germany
3 shared publicationsFrederik B. Laun
3 shared publicationsLothar R. Schad
3 shared publications- Angelika Alonso
Department of Neurology, UniversitätsMedizin Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany
1 shared publication - Friederike L Langhauser
Department of Neurology, Universitätsmedizin Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
1 shared publication
Latest Publications
- Open Access
- 28 February 2013
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 23 (1) , 46-55
Toward a non-invasive screening tool for differentiation of pancreatic lesions based on intra-voxel incoherent motion derived parameters
- 28 February 2013
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 23 (1) , 46-55
Open AccessToward a non-invasive screening tool for differentiation of pancreatic lesions based on intra-voxel incoherent motion derived parameters
- Open Access
- 12 September 2012
- Published by Springer Nature in Experimental & Translational Stroke Medicine
- Vol. 4 (1) , 18
Thromboembolic stroke in C57BL/6 mice monitored by 9.4 T MRI using a 1H cryo probe
Background: A new thromboembolic animal model showed beneficial effects of t-PA with an infarct volume reduction of 36.8% in swiss mice. Because knock-out animal experiments for stroke frequently used C57BL76 mice we evaluated t-PA effects in this mouse strain and measured infarct volume and vascular recanalisation in-vivo by using high-field 9.4 T MRI and a 1H surface cryo coil. Methods: Clot formation was triggered by microinjection of murine thrombin into the right middle cerebral artery (MCA). Animals (n = 28) were treated with 10 mg/kg, 5 mg/kg or no tissue plasminogen activator (t-PA) 40 min after MCA occlusion. For MR-imaging a Bruker 9.4 T animal system with a 1H surface cryo probe was used and a T2-weighted RARE sequence, a diffusion weighted multishot EPI sequence and a 3D flow-compensated gradient echo TOF angiography were performed. Results: The infarct volume in animals treated with t-PA was significantly reduced (0.67 ± 1.38 mm3 for 10 mg/kg and 10.9 ± 8.79 mm3 for 5 mg/kg vs. 19.76 ± 2.72 mm3 ; p < 0.001) compared to untreated mice. An additional group was reperfused with t-PA inside the MRI. Already ten minutes after beginning of t-PA treatment, reperfusion flow was re-established in the right MCA. However, signal intensity was lower than in the contralateral MCA. This reduction in cerebral blood flow was attenuated during the first 60 minutes after reperfusion. 24 h after MCA occlusion and reperfusion, no difference in signal intensity of the contralateral and ipsilateral MCAs was observed. Conclusions: We confirm a t-Pa effect using this stroke model in the C57BL76 mouse strain and demonstrate a chronological sequence MRI imaging after t-PA using a 1H surface cryo coil in a 9.4 T MRI. This setting will allow testing of new thrombolytic strategies for stroke treatment in-vivo in C57BL76 knock-out mice.
- 12 September 2012
- Published by Springer Nature in Experimental & Translational Stroke Medicine
- Vol. 4 (1) , 18
Open AccessThromboembolic stroke in C57BL/6 mice monitored by 9.4 T MRI using a 1H cryo probe
Background: A new thromboembolic animal model showed beneficial effects of t-PA with an infarct volume reduction of 36.8% in swiss mice. Because knock-out animal experiments for stroke frequently used C57BL76 mice we evaluated t-PA effects in this mouse strain and measured infarct volume and vascular recanalisation in-vivo by using high-field 9.4 T MRI and a 1H surface cryo coil. Methods: Clot formation was triggered by microinjection of murine thrombin into the right middle cerebral artery (MCA). Animals (n = 28) were treated with 10 mg/kg, 5 mg/kg or no tissue plasminogen activator (t-PA) 40 min after MCA occlusion. For MR-imaging a Bruker 9.4 T animal system with a 1H surface cryo probe was used and a T2-weighted RARE sequence, a diffusion weighted multishot EPI sequence and a 3D flow-compensated gradient echo TOF angiography were performed. Results: The infarct volume in animals treated with t-PA was significantly reduced (0.67 ± 1.38 mm3 for 10 mg/kg and 10.9 ± 8.79 mm3 for 5 mg/kg vs. 19.76 ± 2.72 mm3 ; p < 0.001) compared to untreated mice. An additional group was reperfused with t-PA inside the MRI. Already ten minutes after beginning of t-PA treatment, reperfusion flow was re-established in the right MCA. However, signal intensity was lower than in the contralateral MCA. This reduction in cerebral blood flow was attenuated during the first 60 minutes after reperfusion. 24 h after MCA occlusion and reperfusion, no difference in signal intensity of the contralateral and ipsilateral MCAs was observed. Conclusions: We confirm a t-Pa effect using this stroke model in the C57BL76 mouse strain and demonstrate a chronological sequence MRI imaging after t-PA using a 1H surface cryo coil in a 9.4 T MRI. This setting will allow testing of new thrombolytic strategies for stroke treatment in-vivo in C57BL76 knock-out mice.
- 1 July 2011
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 29 (6) , 766-776
Toward an optimal distribution of b values for intravoxel incoherent motion imaging
- 1 July 2011
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 29 (6) , 766-776
Toward an optimal distribution of b values for intravoxel incoherent motion imaging
- Open Access
- 23 November 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 64 (6) , 1580-1585
An in vivo verification of the intravoxel incoherent motion effect in diffusion‐weighted imaging of the abdomen
To investigate the vascular contribution to the measured apparent diffusion coefficient and to validate the Intra Voxel Incoherent Motion theory, the signal as a function of the b‐value was measured in the healthy pancreas with and without suppression of the vascular component and under varying echo times (TE = 50, 70, and 100 msec). The perfusion fraction f and the diffusion coefficient D were extracted from the measured DW‐data using the original Intra Voxel Incoherent Motion‐equation and a modified version of this equation incorporating relaxation effects. First, the perfusion fraction f in the blood suppressed pancreatic tissue decreased significantly (P = 0.03), whereas the diffusion coefficient D did not change with suppression (P = 0.43). Second, the perfusion fraction f increased significantly with increasing echo time (P = 0.0025), whereas the relaxation time compensated perfusion fraction f′ showed no significant dependence on TE (P = 0.31). These results verify a vascular contribution to the diffusion weighted imaging measurement at low b values and support the Intra Voxel Incoherent Motion‐theory. Magn Reson Med, 2010.
- 23 November 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 64 (6) , 1580-1585
Open AccessAn in vivo verification of the intravoxel incoherent motion effect in diffusion‐weighted imaging of the abdomen
To investigate the vascular contribution to the measured apparent diffusion coefficient and to validate the Intra Voxel Incoherent Motion theory, the signal as a function of the b‐value was measured in the healthy pancreas with and without suppression of the vascular component and under varying echo times (TE = 50, 70, and 100 msec). The perfusion fraction f and the diffusion coefficient D were extracted from the measured DW‐data using the original Intra Voxel Incoherent Motion‐equation and a modified version of this equation incorporating relaxation effects. First, the perfusion fraction f in the blood suppressed pancreatic tissue decreased significantly (P = 0.03), whereas the diffusion coefficient D did not change with suppression (P = 0.43). Second, the perfusion fraction f increased significantly with increasing echo time (P = 0.0025), whereas the relaxation time compensated perfusion fraction f′ showed no significant dependence on TE (P = 0.31). These results verify a vascular contribution to the diffusion weighted imaging measurement at low b values and support the Intra Voxel Incoherent Motion‐theory. Magn Reson Med, 2010.
- 1 December 2009
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 44 (12) , 769-775
Differentiation of Pancreas Carcinoma From Healthy Pancreatic Tissue Using Multiple b-Values
Objectives: To evaluate in detail the diagnostic performance of diffusion-weighted imaging (DWI) to differentiate pancreas carcinoma from healthy pancreas using the apparent diffusion coefficient (ADC) and parameters derived from the intravoxel incoherent motion (IVIM) theory. Materials and Methods: Twenty-three patients with pancreas carcinoma and 14 volunteers with healthy pancreas were examined at 1.5 Tesla using a single-shot echo-planar imaging DWI pulse sequence. Eleven b-values ranging from 0 to 800 s/mm2 were used. The acquisition was separated into blocks (b0, b25), (b0, b50),...(b0, b800) and each block was acquired in a single expirational breath-hold (TA = 26 seconds) to avoid motion artifacts. The ADC was calculated for all b-values using linear regression yielding ADCtot. By applying the IVIM model, which allows for the estimation of perfusion effects in DWI, the perfusion fraction f and the perfusion free diffusion parameter D were calculated. The diagnostic performance of ADC, f and D as a measure for the differentiation between healthy pancreas and pancreatic carcinoma was evaluated with receiver operating characteristics analysis. Results: In the healthy control group, the ADCtot ranged from 1.53 to 2.01 μm2/ms with a mean value of 1.71 ± 0.19 μm2/ms, the perfusion fraction f ranged from 18.5% to 40.4% with a mean value of 25.0 ± 6.2%, and the diffusion coefficient D from 0.94 to 1.28 μm2/ms with a mean value of 1.13 ± 0.15 μm2/ms. In patients with pancreas carcinoma, the ADCtot ranged from 0.98 to 1.81 μm2/ms with a mean value of 1.31 ± 0.24 μm2/ms, the perfusion fraction f ranged from 0% to 20.4% with a mean value of 8.59 ± 4.6% and the diffusion coefficient D from 0.74 to 1.60 μm2/ms with a mean value of 1.15 ± 0.22 μm2/ms. In comparison to healthy pancreatic tissue, a significant reduction of the perfusion fraction f and of ADCtot was found in pancreatic carcinoma (P < 0.00001, 0.0002, respectively). The f value showed more than a 10-fold higher significance level in distinguishing cancerous from normal tissue when compared with the ADCtot value. No significant difference in the diffusion coefficient D was observed between the 2 groups (P > 0.5). In the receiver operating characteristic-analyses, the area under curve for f was 0.991 and significantly larger than ADCtot (P < 0.05). f had the highest sensitivity, specificity, negative predictive value, and positive predictive value with 95.7%, 100%, 93.3%, and 100%, respectively. Conclusions: Using the IVIM-approach, the f value proved to be the best parameter for the differentiation between healthy pancreas and pancreatic cancer. The acquisition of several b-values strongly improved the stability of the parameter estimation thus increasing the sensitivity and specificity to 95.7% and 100% respectively. The proposed method may hold great promise for the non invasive, noncontrast-enhanced imaging of pancreas lesions and may eventually become a screening tool for pancreatic cancer.
- 1 December 2009
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 44 (12) , 769-775
Differentiation of Pancreas Carcinoma From Healthy Pancreatic Tissue Using Multiple b-Values
Objectives: To evaluate in detail the diagnostic performance of diffusion-weighted imaging (DWI) to differentiate pancreas carcinoma from healthy pancreas using the apparent diffusion coefficient (ADC) and parameters derived from the intravoxel incoherent motion (IVIM) theory. Materials and Methods: Twenty-three patients with pancreas carcinoma and 14 volunteers with healthy pancreas were examined at 1.5 Tesla using a single-shot echo-planar imaging DWI pulse sequence. Eleven b-values ranging from 0 to 800 s/mm2 were used. The acquisition was separated into blocks (b0, b25), (b0, b50),...(b0, b800) and each block was acquired in a single expirational breath-hold (TA = 26 seconds) to avoid motion artifacts. The ADC was calculated for all b-values using linear regression yielding ADCtot. By applying the IVIM model, which allows for the estimation of perfusion effects in DWI, the perfusion fraction f and the perfusion free diffusion parameter D were calculated. The diagnostic performance of ADC, f and D as a measure for the differentiation between healthy pancreas and pancreatic carcinoma was evaluated with receiver operating characteristics analysis. Results: In the healthy control group, the ADCtot ranged from 1.53 to 2.01 μm2/ms with a mean value of 1.71 ± 0.19 μm2/ms, the perfusion fraction f ranged from 18.5% to 40.4% with a mean value of 25.0 ± 6.2%, and the diffusion coefficient D from 0.94 to 1.28 μm2/ms with a mean value of 1.13 ± 0.15 μm2/ms. In patients with pancreas carcinoma, the ADCtot ranged from 0.98 to 1.81 μm2/ms with a mean value of 1.31 ± 0.24 μm2/ms, the perfusion fraction f ranged from 0% to 20.4% with a mean value of 8.59 ± 4.6% and the diffusion coefficient D from 0.74 to 1.60 μm2/ms with a mean value of 1.15 ± 0.22 μm2/ms. In comparison to healthy pancreatic tissue, a significant reduction of the perfusion fraction f and of ADCtot was found in pancreatic carcinoma (P < 0.00001, 0.0002, respectively). The f value showed more than a 10-fold higher significance level in distinguishing cancerous from normal tissue when compared with the ADCtot value. No significant difference in the diffusion coefficient D was observed between the 2 groups (P > 0.5). In the receiver operating characteristic-analyses, the area under curve for f was 0.991 and significantly larger than ADCtot (P < 0.05). f had the highest sensitivity, specificity, negative predictive value, and positive predictive value with 95.7%, 100%, 93.3%, and 100%, respectively. Conclusions: Using the IVIM-approach, the f value proved to be the best parameter for the differentiation between healthy pancreas and pancreatic cancer. The acquisition of several b-values strongly improved the stability of the parameter estimation thus increasing the sensitivity and specificity to 95.7% and 100% respectively. The proposed method may hold great promise for the non invasive, noncontrast-enhanced imaging of pancreas lesions and may eventually become a screening tool for pancreatic cancer.