S. A. Nicolau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
S. A. Nicolau has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
L. Soler
4 shared publicationsN. Ayache
4 shared publications- Xavier Pennec
Université Côte d’Azur, Inria
4 shared publications A. Garcia
1 shared publication- Afshin Gangi
Department of Interventional Radiology, University Hospital Strasbourg, Strasbourg, France
1 shared publication J. Marescaux
1 shared publication
Latest Publications
- 1 June 2009
- Published by Elsevier in Medical Image Analysis
- Vol. 13 (3) , 494-506
An augmented reality system for liver thermal ablation: Design and evaluation on clinical cases
- 1 June 2009
- Published by Elsevier in Medical Image Analysis
- Vol. 13 (3) , 494-506
An augmented reality system for liver thermal ablation: Design and evaluation on clinical cases
- 1 January 2007
- Published by Springer Nature
- Vol. 10, 77-85
Clinical Evaluation of a Respiratory Gated Guidance System for Liver Punctures
We have previously proposed a computer guidance system for liver punctures designed for intubated (free breathing) patients. The lack of accuracy reported (1 cm) was mostly due to the breathing motion that was not taken into account. In this paper we modify our system to synchronise the guidance information on the expiratory phases of the patient and present an evaluation on 6 patients of our respiratory gated system. Firstly, we show how a specific choice of patient allows us to rigorously and passively evaluate the system accuracy. Secondly, we demonstrate that our system can provide a guidance information with an error below 5 mm during expiratory phases.
- 1 January 2007
- Published by Springer Nature
- Vol. 10, 77-85
Clinical Evaluation of a Respiratory Gated Guidance System for Liver Punctures
We have previously proposed a computer guidance system for liver punctures designed for intubated (free breathing) patients. The lack of accuracy reported (1 cm) was mostly due to the breathing motion that was not taken into account. In this paper we modify our system to synchronise the guidance information on the expiratory phases of the patient and present an evaluation on 6 patients of our respiratory gated system. Firstly, we show how a specific choice of patient allows us to rigorously and passively evaluate the system accuracy. Secondly, we demonstrate that our system can provide a guidance information with an error below 5 mm during expiratory phases.
- 15 February 2005
- Published by Wiley in Computer Animation and Virtual Worlds
- Vol. 16 (1) , 1-10
An augmented reality system to guide radio-frequency tumour ablation
- 15 February 2005
- Published by Wiley in Computer Animation and Virtual Worlds
- Vol. 16 (1) , 1-10
An augmented reality system to guide radio-frequency tumour ablation
- 1 January 2005
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 8, 539-547
A Complete Augmented Reality Guidance System for Liver Punctures: First Clinical Evaluation
We provided in [14] an augmented reality guidance system for liver punctures, which has been validated on a static abdominal phantom [16]. In this paper, we report the first in vivo experiments. We developed a strictly passive protocol to directly evaluate our system on patients. We show that the system algorithms work efficiently and we highlight the clinical constraints that we had to overcome (small operative field, weight and sterility of the tracked marker attached to the needle...). Finally, we investigate to what extent breathing motion can be neglected for free breathing patient. Results show that the guiding accuracy, close to 1 cm, is sufficient for large targets only (above 3 cm of diameter) when the breathing motion is neglected. In the near future, we aim at validating our system on smaller targets using a respiratory gating technique.
- 1 January 2005
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 8, 539-547
A Complete Augmented Reality Guidance System for Liver Punctures: First Clinical Evaluation
We provided in [14] an augmented reality guidance system for liver punctures, which has been validated on a static abdominal phantom [16]. In this paper, we report the first in vivo experiments. We developed a strictly passive protocol to directly evaluate our system on patients. We show that the system algorithms work efficiently and we highlight the clinical constraints that we had to overcome (small operative field, weight and sterility of the tracked marker attached to the needle...). Finally, we investigate to what extent breathing motion can be neglected for free breathing patient. Results show that the guiding accuracy, close to 1 cm, is sufficient for large targets only (above 3 cm of diameter) when the breathing motion is neglected. In the near future, we aim at validating our system on smaller targets using a respiratory gating technique.