Giuseppe Barletta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Giuseppe Barletta has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Fabio Fantini
Cardiovascular Disease Unit, Department of Cardiology, Careggi Hospital, University of Florence, Italy
2 shared publications- Francesco Cappelli
Tuscan Regional Amyloidosis Centre, Careggi University Hospital, Florence, Italy
2 shared publications Riccarda Del Bene
Cardiovascular Disease Unit, Department of Cardiology, Careggi Hospital, University of Florence, Italy
2 shared publicationsA. Toso
1 shared publicationC Gallini
Nuclear Medicine Unit, Careggi Hospital, University of Florence, Florence, Italy
1 shared publicationChiara Gallini
1 shared publication
Latest Publications
- 9 August 2011
- Published by Wiley in Echocardiography
- Vol. 28 (8) , E168-E171
The Challenge of Integrated Echocardiographic Approach in Percutaneous Closure of Paravalvular Leak
Paravalvular leak after prosthetic mitral valve surgery may lead to symptomatic mitral regurgitation and hemolytic anemia requiring reoperation. Percutaneous closure of paravalvular leaks is a relatively recent technique still considered a challenging procedure burdened by possible complications, to be offered only to poor redo surgical candidate patients. Multimodality imaging is advocated to plan and guide the procedure, to minimize the risk of complications. We report on a case of dehisced prosthetic mitral valve in which transthoracic real time three-dimensional echocardiography was used to locate the dehiscence area and characterize mitral paraprosthesis leak, whereas intracardiac echocardiography was used to guide and monitor the percutaneous closure procedure.
- 9 August 2011
- Published by Wiley in Echocardiography
- Vol. 28 (8) , E168-E171
The Challenge of Integrated Echocardiographic Approach in Percutaneous Closure of Paravalvular Leak
Paravalvular leak after prosthetic mitral valve surgery may lead to symptomatic mitral regurgitation and hemolytic anemia requiring reoperation. Percutaneous closure of paravalvular leaks is a relatively recent technique still considered a challenging procedure burdened by possible complications, to be offered only to poor redo surgical candidate patients. Multimodality imaging is advocated to plan and guide the procedure, to minimize the risk of complications. We report on a case of dehisced prosthetic mitral valve in which transthoracic real time three-dimensional echocardiography was used to locate the dehiscence area and characterize mitral paraprosthesis leak, whereas intracardiac echocardiography was used to guide and monitor the percutaneous closure procedure.
- 1 November 2010
- Vol. 11 (11) , 860
[Three-dimensional transesophageal evaluation of prosthetic perivalvular leak].
- 1 November 2010
- Vol. 11 (11) , 860
[Three-dimensional transesophageal evaluation of prosthetic perivalvular leak].
- 1 July 2001
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 6 (3) , 222-228
The Normal Sequence of Right and Left Atrial Contraction
Objective: To study the sequence of atrial activation and the interatrial electromechanical delay (IEmD) noninvasively in healthy subjects during sinus rhythm (SR).Methods and Results: In 66 SR healthy subjects P‐wave activation was analyzed by means of vectorcardiography. The timing of atrial contractions was measured as the intervals between the P‐wave and the A‐wave of the Doppler right and left ventricular inflows (P‐At and P‐Am), and IEmD was calculated as the algebraic difference PAm P‐At. In the horizontal plane the vectorcardiographic P‐loop was anteroposterior (“typical”, 41 subjects), anterior (18), or posterior (7). IEmD (mean ±; SE 17 ±; 8 ms) was directly related to R‐R and P‐R intervals. IEmD was significantly shorter in anterior and posterior P loops than in the typical (6.5 ±; 5.3 and 8.1 ±; 10.1, respectively, vs 24.2 ±; 3.1 ms). In the posterior P‐loop group, who exhibited longer P‐At, mitral E‐wave velocity and E/A ratio were reduced, and left atrial booster function was increased.Conclusion: IEmD was widely variable in SR, reflecting the origin site of sinus impulse, which independently influenced ventricular filling dynamics. A.N.E. 2001;6(3):222–228
- 1 July 2001
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 6 (3) , 222-228
The Normal Sequence of Right and Left Atrial Contraction
Objective: To study the sequence of atrial activation and the interatrial electromechanical delay (IEmD) noninvasively in healthy subjects during sinus rhythm (SR).Methods and Results: In 66 SR healthy subjects P‐wave activation was analyzed by means of vectorcardiography. The timing of atrial contractions was measured as the intervals between the P‐wave and the A‐wave of the Doppler right and left ventricular inflows (P‐At and P‐Am), and IEmD was calculated as the algebraic difference PAm P‐At. In the horizontal plane the vectorcardiographic P‐loop was anteroposterior (“typical”, 41 subjects), anterior (18), or posterior (7). IEmD (mean ±; SE 17 ±; 8 ms) was directly related to R‐R and P‐R intervals. IEmD was significantly shorter in anterior and posterior P loops than in the typical (6.5 ±; 5.3 and 8.1 ±; 10.1, respectively, vs 24.2 ±; 3.1 ms). In the posterior P‐loop group, who exhibited longer P‐At, mitral E‐wave velocity and E/A ratio were reduced, and left atrial booster function was increased.Conclusion: IEmD was widely variable in SR, reflecting the origin site of sinus impulse, which independently influenced ventricular filling dynamics. A.N.E. 2001;6(3):222–228
- 1 July 1999
- Published by Elsevier in International Journal of Cardiology
- Vol. 70 (2) , 179-189
The clinical impact of dynamic intraventricular obstruction during dobutamine stress echocardiography
- 1 July 1999
- Published by Elsevier in International Journal of Cardiology
- Vol. 70 (2) , 179-189
The clinical impact of dynamic intraventricular obstruction during dobutamine stress echocardiography
- 1 January 1999
- Published by Wolters Kluwer Health in Coronary Artery Disease
- Vol. 10 (7) , 479-488
Simultaneous dobutamine stress echocardiography and 99mTc-tetrofosmin three-head single-photon emission computed tomography in patients with suspected coronary artery disease
Dobutamine stress echocardiography and 99mTc-tetrofosmin single-photon emission computed tomography (T-SPECT) were performed simultaneously in subjects in whom coronary artery disease (CAD) had been proven or excluded at coronary angiography, in order to establish their accuracy and agreement in the diagnosis of CAD, and in localisation and evaluation of the extension of ischaemia. No simultaneous comparison of the two techniques has been performed previously. Seventy patients (50 men, mean age 63 ± 10 years, 21 with previous myocardial infarction) underwent simultaneous dobutamine stress echocardiography and T-SPECT. The response to stress was blindly and independently analysed, adopting a 16-region segmentation and referring to the three major coronary arteries. Sixty-two patients (agreement 89%, kappa = 0.776) and 91% of left ventricular regions (kappa = 0.665) were classified concordantly, independently of the presence or absence of previous myocardial infarction (90%, kappa = 0.740 versus 91%, kappa = 0.589, respectively). At coronary angiography, 47 patients had CAD (disease prevalence 67%). The sensitivity and specificity of stress echocardiography for the diagnosis of anterior descending, circumflex and right coronary artery disease were 62, 78 and 73%, and 79, 79 and 83%, respectively. The corresponding values for T-SPECT were 70, 75 and 78%, and 94, 79 and 90%, respectively. These data indicate a high concordance between wall motion abnormalities observed using stress echocardiography and perfusion defects observed using T-SPECT; their sensitivity in identifying critical stenoses was similar. Inadequate stressor amounts, and less frequently hyperdynamic regional response may reduce the accuracy of stress echocardiography, while dobutamine effects on coronary flow may prevent T-SPECT from showing subtle flow maldistributions in the presence of worsened wall motion.
- 1 January 1999
- Published by Wolters Kluwer Health in Coronary Artery Disease
- Vol. 10 (7) , 479-488
Simultaneous dobutamine stress echocardiography and 99mTc-tetrofosmin three-head single-photon emission computed tomography in patients with suspected coronary artery disease
Dobutamine stress echocardiography and 99mTc-tetrofosmin single-photon emission computed tomography (T-SPECT) were performed simultaneously in subjects in whom coronary artery disease (CAD) had been proven or excluded at coronary angiography, in order to establish their accuracy and agreement in the diagnosis of CAD, and in localisation and evaluation of the extension of ischaemia. No simultaneous comparison of the two techniques has been performed previously. Seventy patients (50 men, mean age 63 ± 10 years, 21 with previous myocardial infarction) underwent simultaneous dobutamine stress echocardiography and T-SPECT. The response to stress was blindly and independently analysed, adopting a 16-region segmentation and referring to the three major coronary arteries. Sixty-two patients (agreement 89%, kappa = 0.776) and 91% of left ventricular regions (kappa = 0.665) were classified concordantly, independently of the presence or absence of previous myocardial infarction (90%, kappa = 0.740 versus 91%, kappa = 0.589, respectively). At coronary angiography, 47 patients had CAD (disease prevalence 67%). The sensitivity and specificity of stress echocardiography for the diagnosis of anterior descending, circumflex and right coronary artery disease were 62, 78 and 73%, and 79, 79 and 83%, respectively. The corresponding values for T-SPECT were 70, 75 and 78%, and 94, 79 and 90%, respectively. These data indicate a high concordance between wall motion abnormalities observed using stress echocardiography and perfusion defects observed using T-SPECT; their sensitivity in identifying critical stenoses was similar. Inadequate stressor amounts, and less frequently hyperdynamic regional response may reduce the accuracy of stress echocardiography, while dobutamine effects on coronary flow may prevent T-SPECT from showing subtle flow maldistributions in the presence of worsened wall motion.
- 1 December 1998
- Published by S. Karger AG in Cardiology
- Vol. 90 (3) , 195-201
Regional and Temporal Nonuniformity of Shape and Wall Movement in the Normal Left Ventricle
Asymmetry of left ventricular (LV) shape and asynchrony of regional LV movement have been described in the normal human heart, but never correlated to each other. In 16 normal subjects, right anterior oblique ventriculography was used to obtain volumes, regional wall motion (centerline method) and curvature (windowed Fourier series approximation of contours) over the entire cardiac cycle. The apex had the greatest curvature, while the posterior wall had a negative end-diastolic curvature that decreased further at early-systole and became positive at end-systole. The anterior region had the greatest and the anteroapical region the least fractional shortening. Asynchrony was evident as a delayed contraction of the infero- and anteroapical regions, and as a greater rate of late-systolic shortening of the anterior wall than that of the apex. Shape changes and shortening were dyssynchronous in the apical regions where the greatest changes occurred at early diastole. Temporal and regional nonuniformity of shape and movement exists in normal subjects. Dyssynchrony between shape and regional contraction of the apical regions deserves further studies.
- 1 December 1998
- Published by S. Karger AG in Cardiology
- Vol. 90 (3) , 195-201
Regional and Temporal Nonuniformity of Shape and Wall Movement in the Normal Left Ventricle
Asymmetry of left ventricular (LV) shape and asynchrony of regional LV movement have been described in the normal human heart, but never correlated to each other. In 16 normal subjects, right anterior oblique ventriculography was used to obtain volumes, regional wall motion (centerline method) and curvature (windowed Fourier series approximation of contours) over the entire cardiac cycle. The apex had the greatest curvature, while the posterior wall had a negative end-diastolic curvature that decreased further at early-systole and became positive at end-systole. The anterior region had the greatest and the anteroapical region the least fractional shortening. Asynchrony was evident as a delayed contraction of the infero- and anteroapical regions, and as a greater rate of late-systolic shortening of the anterior wall than that of the apex. Shape changes and shortening were dyssynchronous in the apical regions where the greatest changes occurred at early diastole. Temporal and regional nonuniformity of shape and movement exists in normal subjects. Dyssynchrony between shape and regional contraction of the apical regions deserves further studies.