Wies Maarse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wies Maarse has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Aebele B. Mink van der Molen
Department of Plastic and Reconstructive Surgery, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands
3 shared publicationsChantal W. B. Boonacker
Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht, The Netherlands
3 shared publicationsMoshe Kon
Department of Plastic and Reconstructive Surgery, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands
3 shared publicationsCorstiaan C. Breugem
Department of Plastic and Reconstructive Surgery, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands
2 shared publicationsJohannes J. M. van Delden
Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht, The Netherlands
2 shared publicationsM. Kon
2 shared publications
Latest Publications
- Open Access
- 21 March 2018
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 55 (8) , 1158-1165
Parental Attitude Toward the Prenatal Diagnosis of Oral Cleft
Objectives: The prenatal diagnosis of oral clefts (OCs) by ultrasound can pose an ethical dilemma. The purpose of this study was to obtain insight into the psychosocial and moral considerations of prospective parents concerning OCs, the burden of OCs and parents’ attitude toward possible termination of pregnancy (TOP) in order to improve counseling in the future. Design: Between August 2011 and August 2014, a prospective cohort questionnaire study was administered. Setting: Prenatal care clinic of the Wilhelmina’s Children hospital, a Tertiary Care Centre. Participants: Parents expecting a child with an OC. Main Outcome Measures: Expectation of OCs in general and attitudes toward the impact and expected burden of the OC of their child. Furthermore, parents were asked if they had considered TOP. Results: Most of the parents described an OC as a cosmetic disability (50.6%) or as “just a little different” (29.4%). These parents expected that the OC would not affect their own happiness and have only minor influence on the happiness of their future child. Health professionals had a considerable influence on parental opinion. A minority (6.4%, 5/85) of the respondents considered TOP, and none of the responders chose to terminate the pregnancy. Conclusions: This study suggests that future parents have very few negative perceptions of OC after prenatal counseling. Caregivers should be aware that their counseling is important for decision-making of parents.
- 21 March 2018
- Published by SAGE Publications in The Cleft Palate Craniofacial Journal
- Vol. 55 (8) , 1158-1165
Open AccessParental Attitude Toward the Prenatal Diagnosis of Oral Cleft
Objectives: The prenatal diagnosis of oral clefts (OCs) by ultrasound can pose an ethical dilemma. The purpose of this study was to obtain insight into the psychosocial and moral considerations of prospective parents concerning OCs, the burden of OCs and parents’ attitude toward possible termination of pregnancy (TOP) in order to improve counseling in the future. Design: Between August 2011 and August 2014, a prospective cohort questionnaire study was administered. Setting: Prenatal care clinic of the Wilhelmina’s Children hospital, a Tertiary Care Centre. Participants: Parents expecting a child with an OC. Main Outcome Measures: Expectation of OCs in general and attitudes toward the impact and expected burden of the OC of their child. Furthermore, parents were asked if they had considered TOP. Results: Most of the parents described an OC as a cosmetic disability (50.6%) or as “just a little different” (29.4%). These parents expected that the OC would not affect their own happiness and have only minor influence on the happiness of their future child. Health professionals had a considerable influence on parental opinion. A minority (6.4%, 5/85) of the respondents considered TOP, and none of the responders chose to terminate the pregnancy. Conclusions: This study suggests that future parents have very few negative perceptions of OC after prenatal counseling. Caregivers should be aware that their counseling is important for decision-making of parents.
- 14 July 2015
- Published by Wiley in Prenatal Diagnosis
- Vol. 35 (9) , 894-900
A practical prenatal ultrasound classification system for common oral clefts
What's already known about this topic? Oral cleft is the most common congenital facial malformation, with increased detection prenatally. An accurate diagnosis is essential because different types of cleft are associated with specific risks of anomalies and chromosomal disorders. Former classification of oral cleft is outdated. What does this study add? The new prenatal ultrasound classification system presented here offers a systematic and practical approach for prenatal screening of oral clefts and, and unlike former classification, provides an accurate correlation with the postnatal cleft diagnosis. The classification is based on a commonly used postnatal system; therefore, it will improve communication between obstetricians and cleft lip and palate teams. © 2015 John Wiley & Sons, Ltd.
- 14 July 2015
- Published by Wiley in Prenatal Diagnosis
- Vol. 35 (9) , 894-900
A practical prenatal ultrasound classification system for common oral clefts
What's already known about this topic? Oral cleft is the most common congenital facial malformation, with increased detection prenatally. An accurate diagnosis is essential because different types of cleft are associated with specific risks of anomalies and chromosomal disorders. Former classification of oral cleft is outdated. What does this study add? The new prenatal ultrasound classification system presented here offers a systematic and practical approach for prenatal screening of oral clefts and, and unlike former classification, provides an accurate correlation with the postnatal cleft diagnosis. The classification is based on a commonly used postnatal system; therefore, it will improve communication between obstetricians and cleft lip and palate teams. © 2015 John Wiley & Sons, Ltd.
- 1 March 2015
- Published by Wiley in Prenatal Diagnosis
- Vol. 35 (6) , 544-548
Professional opinion on oral cleft during pregnancy: a comparison between Israel and the Netherlands
Objective To assess the opinion of obstetric care providers who perform prenatal ultrasounds to screen for anomalies and who advise women about their options, including termination of pregnancy, when an oral cleft is detected. We compared providers' opinions about pregnancy termination for isolated oral cleft in the Netherlands, where the number of terminations is low, and in Israel, where the number is high. Methods Online questionnaires were used. The questions assessed the providers' views regarding the estimated burden of treatment, the functioning ability and the level of happiness of children with an oral cleft and their parents. Additionally, we assessed providers' opinions on pregnancy termination for isolated oral cleft. Results In the Netherlands, more professionals considered oral cleft a disability [rate differences (RD) 17.8%, 95% CI: 0.5‐33.1%] than in Israel. In the Netherlands, 10.6% of respondents (compared with 11.1% in Israel) thought that an isolated cleft was a reason for TOP [RD 0.6%, 95% CI: −12‐10.9%]. Conclusions Prenatal care providers in the Netherlands and Israel do not differ in their opinions about the severity of oral cleft and the acceptability of TOP for an isolated oral cleft. This study shows that prenatal care providers’ attitudes do therefore not explain the dramatic difference between these countries in the number of TOP for isolated oral cleft.
- 1 March 2015
- Published by Wiley in Prenatal Diagnosis
- Vol. 35 (6) , 544-548
Professional opinion on oral cleft during pregnancy: a comparison between Israel and the Netherlands
Objective To assess the opinion of obstetric care providers who perform prenatal ultrasounds to screen for anomalies and who advise women about their options, including termination of pregnancy, when an oral cleft is detected. We compared providers' opinions about pregnancy termination for isolated oral cleft in the Netherlands, where the number of terminations is low, and in Israel, where the number is high. Methods Online questionnaires were used. The questions assessed the providers' views regarding the estimated burden of treatment, the functioning ability and the level of happiness of children with an oral cleft and their parents. Additionally, we assessed providers' opinions on pregnancy termination for isolated oral cleft. Results In the Netherlands, more professionals considered oral cleft a disability [rate differences (RD) 17.8%, 95% CI: 0.5‐33.1%] than in Israel. In the Netherlands, 10.6% of respondents (compared with 11.1% in Israel) thought that an isolated cleft was a reason for TOP [RD 0.6%, 95% CI: −12‐10.9%]. Conclusions Prenatal care providers in the Netherlands and Israel do not differ in their opinions about the severity of oral cleft and the acceptability of TOP for an isolated oral cleft. This study shows that prenatal care providers’ attitudes do therefore not explain the dramatic difference between these countries in the number of TOP for isolated oral cleft.
- 10 August 2011
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 38 (4) , 434-439
Prenatal ultrasound screening for orofacial clefts
Objectives: To evaluate the sensitivity and specificity of ultrasound for detecting prenatal facial clefts in low‐risk and high‐risk populations.Methods: This study prospectively followed up a non‐selected population, namely all pregnant women who underwent routine second‐trimester prenatal ultrasound screening in the Utrecht region during the 2‐year period from January 2007 to December 2008.Results: A total of 35 924 low‐risk and 2836 high‐risk pregnant women underwent ultrasound screening. Orofacial clefts were present in 62 cases, an incidence of 1:624. The distribution of clefts was as follows: 18 (29%) cleft lip, 25 (40%) cleft lip with cleft palate, 17 (27%) cleft palate only, one median cleft and one atypical cleft. Of these, 38 (61%) were unilateral and 23 (37%) were bilateral. Thirty‐nine per cent (24/62) had associated anomalies, with most chromosomal defects found in the cleft lip with cleft palate and cleft palate only groups. Cleft lip with or without cleft palate was detected prenatally in 38/43 cases, a sensitivity of 88%. No case of cleft palate only was detected prenatally. There were three false‐positive cases, of which two were fetuses with multiple congenital deformities.Conclusions: Ultrasound screening has a high sensitivity for the detection of cleft lip with and without cleft palate in high‐risk and low‐risk pregnancies in our region, where well‐trained sonographers carry out primary screening. The key to a high sensitivity of prenatal ultrasound is likely to be a combination of excellent training of sonographers, referral to specialized centers when a cleft is suspected, routine visualization of the fetal face and advances in ultrasound techniques. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
- 10 August 2011
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 38 (4) , 434-439
Prenatal ultrasound screening for orofacial clefts
Objectives: To evaluate the sensitivity and specificity of ultrasound for detecting prenatal facial clefts in low‐risk and high‐risk populations.Methods: This study prospectively followed up a non‐selected population, namely all pregnant women who underwent routine second‐trimester prenatal ultrasound screening in the Utrecht region during the 2‐year period from January 2007 to December 2008.Results: A total of 35 924 low‐risk and 2836 high‐risk pregnant women underwent ultrasound screening. Orofacial clefts were present in 62 cases, an incidence of 1:624. The distribution of clefts was as follows: 18 (29%) cleft lip, 25 (40%) cleft lip with cleft palate, 17 (27%) cleft palate only, one median cleft and one atypical cleft. Of these, 38 (61%) were unilateral and 23 (37%) were bilateral. Thirty‐nine per cent (24/62) had associated anomalies, with most chromosomal defects found in the cleft lip with cleft palate and cleft palate only groups. Cleft lip with or without cleft palate was detected prenatally in 38/43 cases, a sensitivity of 88%. No case of cleft palate only was detected prenatally. There were three false‐positive cases, of which two were fetuses with multiple congenital deformities.Conclusions: Ultrasound screening has a high sensitivity for the detection of cleft lip with and without cleft palate in high‐risk and low‐risk pregnancies in our region, where well‐trained sonographers carry out primary screening. The key to a high sensitivity of prenatal ultrasound is likely to be a combination of excellent training of sonographers, referral to specialized centers when a cleft is suspected, routine visualization of the fetal face and advances in ultrasound techniques. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
- 16 March 2010
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 35 (4) , 495-502
Diagnostic accuracy of transabdominal ultrasound in detecting prenatal cleft lip and palate: a systematic review
Objectives: To systematically review the diagnostic accuracy of second‐trimester transabdominal ultrasound in detecting orofacial clefts in low‐ and high‐risk populations and to compare two‐dimensional (2D) with three‐dimensional (3D) ultrasound techniques.Methods: MEDLINE and EMBASE were searched for articles published in English, Dutch, French or German using the keywords ‘cleft’ and ‘ultrasound’ or ‘screening’ or ‘sonogram’ and ‘prenatal’ or ‘antenatal’ or ‘fetus’ to identify cohort studies and randomized trials in order to assess the detection rate by prenatal ultrasound of cleft lip and palate in high‐risk and low‐risk pregnant women.Results: Of 451 citations identified, 27 met the criteria for the systematic review, 21 involving unselected low‐risk populations and six involving high‐risk populations. In the selected studies there was diversity in the gestational age at which the ultrasound examination was performed and there was considerable variety in the diagnostic accuracy of 2D ultrasound in the low‐risk women, with prenatal detection rates ranging from 9% to 100% for cleft lip with or without cleft palate, 0% to 22% for cleft palate only and 0% to 73% for all types of cleft. 3D ultrasound in high‐risk women resulted in a detection rate of 100% for cleft lip, 86% to 90% for cleft lip with palate and 0% to 89% for cleft palate only.Conclusions: 2D ultrasound screening for cleft lip and palate in a low‐risk population has a relatively low detection rate but is associated with few false‐positive results. 3D ultrasound can achieve a reliable diagnosis, but not of cleft palate only. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.
- 16 March 2010
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 35 (4) , 495-502
Diagnostic accuracy of transabdominal ultrasound in detecting prenatal cleft lip and palate: a systematic review
Objectives: To systematically review the diagnostic accuracy of second‐trimester transabdominal ultrasound in detecting orofacial clefts in low‐ and high‐risk populations and to compare two‐dimensional (2D) with three‐dimensional (3D) ultrasound techniques.Methods: MEDLINE and EMBASE were searched for articles published in English, Dutch, French or German using the keywords ‘cleft’ and ‘ultrasound’ or ‘screening’ or ‘sonogram’ and ‘prenatal’ or ‘antenatal’ or ‘fetus’ to identify cohort studies and randomized trials in order to assess the detection rate by prenatal ultrasound of cleft lip and palate in high‐risk and low‐risk pregnant women.Results: Of 451 citations identified, 27 met the criteria for the systematic review, 21 involving unselected low‐risk populations and six involving high‐risk populations. In the selected studies there was diversity in the gestational age at which the ultrasound examination was performed and there was considerable variety in the diagnostic accuracy of 2D ultrasound in the low‐risk women, with prenatal detection rates ranging from 9% to 100% for cleft lip with or without cleft palate, 0% to 22% for cleft palate only and 0% to 73% for all types of cleft. 3D ultrasound in high‐risk women resulted in a detection rate of 100% for cleft lip, 86% to 90% for cleft lip with palate and 0% to 89% for cleft palate only.Conclusions: 2D ultrasound screening for cleft lip and palate in a low‐risk population has a relatively low detection rate but is associated with few false‐positive results. 3D ultrasound can achieve a reliable diagnosis, but not of cleft palate only. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.