RMRoss Milner

Ross Milner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ross Milner has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Midterm results of adjunctive neck therapies performed during elective infrarenal aortic aneurysm repair

    by Jayer Chung, Matthew A. Corriere, Ross Milner, Karthikeshwar Kasirajan, Atef Salam, Thomas F. Dodson, Elliott L. Chaikof, Ravi Kumar Veeraswamy


  • PP67. Long-term Surveillance with Wireless Pressure Sensors after Endovascular Aneurysm Repair

    by Edward Li, Jeffrey Wang, Elliott Chaikof, Thomas Dodson, Karthikeshwar Kasirajan, Ravi Veeraswamy, Jennifer Avise, Ross Milner

  • PP63. Mid-term Results of Neck-Related Adjunctive Therapies Utilized During Endovascular Repair of Infra-Renal Aortic Aneurysms

    by Jayer Chung, Karthikeshwar Kasirajan, Ross Milner, Naren Gupta, Elliott Chaikof, Ravi Veeraswamy

  • Endovascular Management Of Blunt Abdominal Aortic Injury

    by Michael E. Halkos, Jeffrey Nicholas, Li Sheng Kong, J.RYan Burke, Ross Milner

    The endovascular management of blunt aortic injuries is being used more frequently in the trauma patient. Traumatic aortic injuries usually occur in the descending thoracic aorta near the origin of the left subclavian artery. Many reports in the literature demonstrate the efficacy of endovascular repair of blunt thoracic aortic injury. We report here an unusual case of abdominal aortic dissection secondary to blunt abdominal trauma following a fall. The patient also had associated intra-abdominal injuries requiring bowel resection and repair of small bowel mesenteric lacerations. He was treated with a bifurcated abdominal endograft with an excellent result after the initial operation was performed to treat the bowel injuries.


  • Unusual Case of Right-Sided May-Thurner Syndrome and Review of Its Management

    by Renee M. Burke, Sunil S. Rayan, Karthikeshwar Kasirajan, Elliot L. Chaikof, Ross Milner

    May-Thurner syndrome is a phenomenon commonly described as an acquired stenosis of the left common iliac vein as a result of right common iliac artery compression. We report an unusual case of right-sided May-Thurner syndrome in a patient found to have a left-sided inferior vena cava. We also review the management of this patient using angioplasty, intraoperative thrombolysis, and endoluminal stent placement.


  • Durability and Validity of a Remote, Miniaturized Pressure Sensor in an Animal Model of Abdominal Aortic Aneurysm

    by Ross Milner, Jelle P. Ruurda, Jan D. Blankensteijn

    Purpose: To investigate whether a remote, miniaturized pressure sensor could maintain calibration and function through organized thrombus over an extended period in a porcine model of abdominal aortic aneurysm (AAA). Methods: Six adult pigs had an AAA surgically created and excluded. A sensor zeroed to atmospheric pressure was placed within the aneurysm sac and another within the suprarenal aorta of each animal. Pressure measurements were taken at the initial operation and then on a weekly basis over 2 months. The aortic sensors were correlated to an intraarterial pressure catheter at the initial operation and at the time of sacrifice. Back-table sensor correlation with atmospheric pressure was done at the time of explantation. Results: Three animals died during the follow-up period. Five animals were available for 6-week follow-up, of which 3 survived for the complete 8-week protocol. Two of the surviving animals had an intra-aortic sensor. All 5 aneurysm sac sensors functioned throughout the experimental period. At the time of sacrifice, the sacs contained a large amount of organized thrombus in which the sac sensors were deeply embedded. The 3 aortic sensors also functioned throughout the course of the experiments. The pressures correlated within 5 mmHg to the catheter-based measurements taken at the initial operation and at the time of sacrifice. Comparison to atmospheric pressure revealed no calibration offset in any sensor. Conclusions: This chronic implantation study demonstrates the durability of a remote, miniaturized pressure sensor within a surgically created aneurysm sac as well as the suprarenal aorta of a porcine AAA model. There was no calibration offset in any of the sensors, and they remained valid at explantation. We believe that this is further evidence of the potential applicability of this sensor for clinical use.


  • Noninvasive Intrasac Pressure Measurement and the Influence of Type 2 and Type 3 Endoleaks in an Animal Model of Abdominal Aortic Aneurysm

    by Ross Milner, Hence J. M. Verhagen, Monique Prinssen, Jan D. Blankensteijn

    The objective of this study was to noninvasively detect pressure changes within an excluded aneurysm sac in an animal model of abdominal aortic aneurysm (AAA) and to study the influence of type 2 and 3 endoleaks. A porcine model of AAA that allows for the creation of type 2 and 3 endoleaks was used. A miniaturized pressure monitoring device (3 X 9 X 1.5 mm; Remon Medical Technologies, Caesarea, Israel) was implanted within the surgically created and excluded aneurysm sac. The pressure monitoring device is an ultrasound-based system that allows for pressure measurements in a noninvasive, transcutaneous fashion. In addition, catheter-based pressures were taken within the aorta and directly in the AAA sac. Noninvasive measurements were taken in a transcutaneous fashion between the initial operation and the time of sacrifice, when the type 3 endoleak was created (2 weeks). The median mean arterial pressure was 66 mm Hg (range 55–120 mm Hg; N = 8). The median noninvasive sac pressure with a type 2 endoleak was 48 mm Hg (range 39–90 mm Hg; N = 8) and was almost identical to the catheter-based measurements. Noninvasive pressures could be measured as early as postprocedure day 1. Two animals had follow-up that suggested closure of the type 2 endoleak during the observation period. With the creation of the type 3 endoleak, the catheter and noninvasive sac pressure and waveform changed from a flatline trace to a higher-pressure pulsatile trace (median 54 mm Hg; range 46–81 mm Hg; N = 8), reproducing the arterial pressure and waveform. This is the first study, to our knowledge, that demonstrates the efficacy of a noninvasive, miniaturized pressure monitoring device in identifying pressure changes in an excluded aneurysm sac with type 2 and type 3 endoleaks. This technology holds great promise for follow-up of patients and identification of sac pressure changes after EVAR and may allow a change in the current follow-up strategy.