Frank Bode
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Frank Bode has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Heribert Schunkert
Medical University Luebeck, Luebeck, Germany
2 shared publications- Michael R. Franz
Cardiology Division, Veteran Affairs Medical Center, 50 Irving St, NW, Washington 20422, DC, USA Department of Pharmacology, Georgetown University Medical Center, Washington, DC, USA
2 shared publications Hendrik Bonnemeier
Medical University Luebeck, Luebeck, Germany
1 shared publication- Hendrik Bonnemeier
Universitätsklinik Schleswig Holstein, Campus Kiel, Klinik für Innere Medizin III, Abteilung für Elektrophysiologie und Rhythmologie, Kiel, Germany
1 shared publication Hugo A. Katus
Medical University of Lübeck, Department of Internal Medicine II, Lübeck, Germany
1 shared publicationIris Wilke
Medical University Luebeck, Luebeck, Germany
1 shared publication
Latest Publications
- 1 August 2011
- Published by Oxford University Press (OUP)
- p. 223-226
Mechanical induction of arrhythmia in the ex situ heart: insight into Commotio cordis
- 1 August 2011
- Published by Oxford University Press (OUP)
- p. 223-226
Mechanical induction of arrhythmia in the ex situ heart: insight into Commotio cordis
- 1 August 2011
- Published by Oxford University Press (OUP)
- p. 168-172
Acute stretch effects on atrial electrophysiology
- 1 August 2011
- Published by Oxford University Press (OUP)
- p. 168-172
Acute stretch effects on atrial electrophysiology
- 26 July 2006
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 17 (9) , 1011-1017
Ventricular Fibrillation Induced by Stretch Pulse: Implications for Sudden Death Due to Commotio Cordis
Introduction: Nonpenetrating chest wall impact (commotio cordis) may lead to sudden cardiac death due to the acute initiation of ventricular fibrillation (VF). VF may result from sudden stretch during a vulnerable window, which is determined by repolarization inhomogeneity. Methods: We examined action potential morphologies and VF inducibility in response to sudden myocardial stretch in the left ventricle (LV). In six Langendorff perfused rabbit hearts, the LV was instrumented with a fluid‐filled balloon. Increasing volume and pressure pulses were applied at different times of the cardiac cycle. Monophasic action potentials (MAPs) were recorded simultaneously from five LV epicardial sites. Inter‐site dispersion of repolarization was calculated in the time and voltage domains. Results: Sudden balloon inflation induced VF when pressure pulses of 208–289 mmHg were applied within a window of 35–88 msec after MAP upstroke, a period of intrinsic increase in repolarization dispersion. During the pressure pulse, MAPs revealed an additional increase in repolarization dispersion (time domain) by 9 ± 6 msec (P < 0.01). The maximal difference in repolarization levels (voltage domain) between sites increased from 19 ± 3% to 26 ± 3% (P < 0.05). Earliest stretch‐induced activation was observed near a site with early repolarization, while sites with late repolarization showed delayed activation. Conclusions: Sudden myocardial stretch can elicit VF when it occurs during a vulnerable window that is based on repolarization inhomogeneity. Stretch pulses applied during this vulnerable window can lead to nonuniform activation. Repolarization dispersion might play a crucial role in the occurrence of fatal tachyarrhythmias during commotio cordis.
- 26 July 2006
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 17 (9) , 1011-1017
Ventricular Fibrillation Induced by Stretch Pulse: Implications for Sudden Death Due to Commotio Cordis
Introduction: Nonpenetrating chest wall impact (commotio cordis) may lead to sudden cardiac death due to the acute initiation of ventricular fibrillation (VF). VF may result from sudden stretch during a vulnerable window, which is determined by repolarization inhomogeneity. Methods: We examined action potential morphologies and VF inducibility in response to sudden myocardial stretch in the left ventricle (LV). In six Langendorff perfused rabbit hearts, the LV was instrumented with a fluid‐filled balloon. Increasing volume and pressure pulses were applied at different times of the cardiac cycle. Monophasic action potentials (MAPs) were recorded simultaneously from five LV epicardial sites. Inter‐site dispersion of repolarization was calculated in the time and voltage domains. Results: Sudden balloon inflation induced VF when pressure pulses of 208–289 mmHg were applied within a window of 35–88 msec after MAP upstroke, a period of intrinsic increase in repolarization dispersion. During the pressure pulse, MAPs revealed an additional increase in repolarization dispersion (time domain) by 9 ± 6 msec (P < 0.01). The maximal difference in repolarization levels (voltage domain) between sites increased from 19 ± 3% to 26 ± 3% (P < 0.05). Earliest stretch‐induced activation was observed near a site with early repolarization, while sites with late repolarization showed delayed activation. Conclusions: Sudden myocardial stretch can elicit VF when it occurs during a vulnerable window that is based on repolarization inhomogeneity. Stretch pulses applied during this vulnerable window can lead to nonuniform activation. Repolarization dispersion might play a crucial role in the occurrence of fatal tachyarrhythmias during commotio cordis.
- 1 November 2005
- Published by Bentham Science Publishers Ltd. in Current Cardiology Reviews
- Vol. 1 (3) , 225-230
Physiological Pacing - Quo Vadis?
Dual chamber pacemaker therapy was considered to be the optimal treatment for most patients with symptomatic bradycardias. During the last decade, the percentage of dual chamber pacing increased to more than 60% in the United States and Western Europe. Yet, recent multicenter trials (CTOPP, MOST, UKPACE) on dual chamber pacemaker therapy failed to demonstrate a clear prognostic advantage compared to single chamber ventricular pacing. Moreover, clinical benefits of dual chamber pacing like a lower incidence of atrial arrhythmias, a reduction of hospitalization for heart failure or quality of life improvements were lower than expected or even absent. This article discusses the above mentioned studies and their limitations, reviews the increasing evidence for avoiding right (apical) ventricular stimulation and presents current approaches to differential pacemaker therapy.
- 1 November 2005
- Published by Bentham Science Publishers Ltd. in Current Cardiology Reviews
- Vol. 1 (3) , 225-230
Physiological Pacing - Quo Vadis?
Dual chamber pacemaker therapy was considered to be the optimal treatment for most patients with symptomatic bradycardias. During the last decade, the percentage of dual chamber pacing increased to more than 60% in the United States and Western Europe. Yet, recent multicenter trials (CTOPP, MOST, UKPACE) on dual chamber pacemaker therapy failed to demonstrate a clear prognostic advantage compared to single chamber ventricular pacing. Moreover, clinical benefits of dual chamber pacing like a lower incidence of atrial arrhythmias, a reduction of hospitalization for heart failure or quality of life improvements were lower than expected or even absent. This article discusses the above mentioned studies and their limitations, reviews the increasing evidence for avoiding right (apical) ventricular stimulation and presents current approaches to differential pacemaker therapy.
- 1 September 2001
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 24 (9) , 1383-1388
Incidence and Predictors of Pacemaker Dysfunction with Unipolar Ventricular Lead Configuration. Can We Identify Patients Who Benefit from Bipolar Electrodes?
Unipolar ventricular leads were implanted in a considerable percentage of pacemaker recipients. There is little information on incidence and risk factors for unipolar pacemaker dysfunction using modern lead designs. Included in a cross-sectional analysis were 682 patients who fulfilled the following criteria: chronically implanted bipolar ventricular leads (> 1 year), intraoperative stimulation threshold < 1.0 V/0.5 ms, and potential amplitude > 6 mV. Incidences of chest wall stimulation (CWS) at an output of twice the amplitude threshold and of myopotential oversensing (MPO) at a sensitivity of half the sensing threshold were assessed. Energy (0.60 [0.72] vs 0.63 [0.81] microJ) and sensing thresholds (8.31 [3.18] mV vs 8.47 [3.47] mV) did not differ between uni- and bipolar modes. While all pacemakers worked properly during bipolar configuration, malfunctions were observed in 5.9% of patients during unipolar configuration (CWS = 1.9%, MPO = 4.2%). Patient age > 76 years (hazard ratio HR 8.2; P < 0.001), heart failure > or = NYHA Class II (HR 3.8; P < 0.001), and an antiarrhythmic therapy with Class I or III drugs (HR 3.3; P = 0.002) were independently associated with the occurrence of unipolar pacemaker dysfunction. Use of steroid-eluting leads reduced the probability of pacemaker dysfunction (HR 0.45; P = 0.03). Risk factors for unipolar ventricular pacemaker malfunction were higher age, heart failure, and antiarrhythmic drug therapy. Particularly in these patients, use of bipolar ventricular leads is beneficial.
- 1 September 2001
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 24 (9) , 1383-1388
Incidence and Predictors of Pacemaker Dysfunction with Unipolar Ventricular Lead Configuration. Can We Identify Patients Who Benefit from Bipolar Electrodes?
Unipolar ventricular leads were implanted in a considerable percentage of pacemaker recipients. There is little information on incidence and risk factors for unipolar pacemaker dysfunction using modern lead designs. Included in a cross-sectional analysis were 682 patients who fulfilled the following criteria: chronically implanted bipolar ventricular leads (> 1 year), intraoperative stimulation threshold < 1.0 V/0.5 ms, and potential amplitude > 6 mV. Incidences of chest wall stimulation (CWS) at an output of twice the amplitude threshold and of myopotential oversensing (MPO) at a sensitivity of half the sensing threshold were assessed. Energy (0.60 [0.72] vs 0.63 [0.81] microJ) and sensing thresholds (8.31 [3.18] mV vs 8.47 [3.47] mV) did not differ between uni- and bipolar modes. While all pacemakers worked properly during bipolar configuration, malfunctions were observed in 5.9% of patients during unipolar configuration (CWS = 1.9%, MPO = 4.2%). Patient age > 76 years (hazard ratio HR 8.2; P < 0.001), heart failure > or = NYHA Class II (HR 3.8; P < 0.001), and an antiarrhythmic therapy with Class I or III drugs (HR 3.3; P = 0.002) were independently associated with the occurrence of unipolar pacemaker dysfunction. Use of steroid-eluting leads reduced the probability of pacemaker dysfunction (HR 0.45; P = 0.03). Risk factors for unipolar ventricular pacemaker malfunction were higher age, heart failure, and antiarrhythmic drug therapy. Particularly in these patients, use of bipolar ventricular leads is beneficial.