ALArmin Lambrecht

Armin Lambrecht

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Armin Lambrecht has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Portable Laser Spectroscopic System for Measuring Nitrous Oxide Emissions on Fertilized Cropland

    by Gerrit Stiefvater, Yvonne Hespos, Dominic Wiedenmann, Armin Lambrecht, Raimund Brunner, Jürgen Wöllenstein

    Nitrous oxide (laughing gas, N2O) is a relevant greenhouse gas. Agriculture contributes significantly to its emissions. As nitrogen fertilization has been identified as one of the main sources of N2O, controlled application and reduction of the amount of fertilizer adapted to crop demand is essential to reduce N2O emissions. This requires detailed studies of the local distribution of the N2O emission fluxes on different croplands. Consequently, frequent spatially resolved field measurements of N2O concentrations are needed. A precision in the ppb range close to the ambient N2O level of 333 ppb is necessary. Tunable laser absorption spectroscopy using quantum-cascade lasers (QCL) as a light source is an established technique for the measurement of N2O traces. We present the development and validation of a compact portable setup for on-site measurement of N2O emissions from the soil. The setup differs from previous solutions by using an interband cascade laser (ICL), which has significantly lower power consumption compared to a QCL. The portable measurement setup allows N2O emission fluxes to be determined with a precision of 3.5% with a measuring duration of 10 min. The developed system enables the detection of increased N2O emissions because of the fertilization of fields. High N2O emission fluxes are indicators of the overfertilization of the field. Directly after fertilization, N2O fluxes between 2.9 and 5.3 µL m−2 min−1 depending on the gas acquisition site are measured during the field tests. Over time, the fluxes decrease. The obtained results compare well with data from more precise but also more complex and maintenance-intensive instruments for atmospheric research. With this system, the soil moisture as well as the air humidity and air temperature are recorded. Strong influences on N2O fluxes by soil moisture were observed. The presented measurement system is a contribution to the establishment of mobile N2O screening systems that are robust in the field and suitable for comprehensive and routine detection of N2O emissions from soil.


  • Open Access

    Compact silicon-based attenuated total reflection (ATR) sensor module for liquid analysis

    by Armin Lambrecht, Carsten Bolwien, Hendrik Fuhr, Gerd Sulz, Annett Isserstedt-Trinke, André Magi, Steffen Biermann, Jürgen Wöllenstein

    Infrared attenuated total reflection (ATR) spectroscopy is a common laboratory technique for the analysis of highly absorbing liquids and solids, and a variety of ATR accessories for laboratory FTIR spectrometers are available. However, ATR spectroscopy is rarely found in industrial processes, where compact, robust, and cost-effective sensors for continuous operation are required. Here, narrowband photometers are more appropriate than FTIR instruments. We show the concept and implementation of a compact Si-based ATR module with a four-channel microelectromechanical systems (MEMS) detector. Measurements of liquid mixtures demonstrate the suitability for applications in the chemical industry. Apart from sapphire (for wavelengths below 5 µm) and diamond (extending to the far-infrared region), most materials for ATR elements do not have either high enough infrared transmission or sufficient mechanical and chemical stability to be exposed to process fluids, abrasive components, or aggressive cleaning agents. However, using diamond coatings on Si improves the stability of the sensor surface. In addition, by proper choice of incidence angle and coating thickness, an enhancement of the ATR absorbance is theoretically expected and demonstrated by first experiments using a compact sensor module with a diamond-coated Si ATR element.

  • Open Access

    Noninvasive Magnetic-Marking-Based Flow Metering with Optically Pumped Magnetometers

    by Leonhard Schmieder, Peter A. Koss, Armin Lambrecht, Frank Kühnemann

    We present a noninvasive procedure that measures the flow velocity of a fluid by using polarized hydrogen nuclei in the fluid. The measurement procedure is based on a time-of-flight method where magnetic information is applied on the fluid with a permanent magnet and an RF-pulse. In contrast to other methods, this magnetic-marking method works without tracers. The read-out of the magnetic information is performed by optically pumped magnetometers downstream. In order to function, the magnetometers have to be operated in a magnetic shield with magnetic field strengths lower than 100 nT, i.e., in the zero-to-ultra-low-field regime. In this regime, the magnetometers are capable of detecting induced magnetic signals of 10 pT or less with an inline-flow setup. The results presented in this paper demonstrate the viability of optically pumped magnetometers for flow metering. The first metering results yielded an average accuracy of 3% at flow velocities between 13 cm/s and 22.4 cm/s.


  • Open Access

    Rapid Quantitative Analysis of IR Absorption Spectra for Trace Gas Detection by Artificial Neural Networks Trained with Synthetic Data

    by Jens Goldschmidt, Leonard Nitzsche, Sebastian Wolf, Armin Lambrecht, Jürgen Wöllenstein

    Infrared absorption spectroscopy is a widely used tool to quantify and monitor compositions of gases. The concentration information is often retrieved by fitting absorption profiles to the acquired spectra, utilizing spectroscopic databases. In complex gas matrices an expanded parameter space leads to long computation times of the fitting routines due to the increased number of spectral features that need to be computed for each iteration during the fit. This hinders the capability of real-time analysis of the gas matrix. Here, an artificial neural network (ANN) is employed for rapid prediction of gas concentrations in complex infrared absorption spectra composed of mixtures of CO and N2O. Experimental data is acquired with a mid-infrared dual frequency comb spectrometer. To circumvent the experimental collection of huge amounts of training data, the network is trained on synthetically generated spectra. The spectra are based on simulated absorption profiles making use of the HITRAN database. In addition, the spectrometer’s influence on the measured spectra is characterized and included in the synthetic training data generation. The ANN was tested on measured spectra and compared to a non-linear least squares fitting algorithm. An average evaluation time of 303 µs for a single measured spectrum was achieved. Coefficients of determination were 0.99997 for the predictions of N2O concentrations and 0.99987 for the predictions of CO concentrations, with uncertainties on the predicted concentrations between 0.04 and 0.18 ppm for 0 to 100 ppm N2O and between 0.05 and 0.18 ppm for 0 to 60 ppm CO.


  • Two-component gas sensing with MIR dual comb spectroscopy

    by Leonard Nitzsche, Jens Goldschmidt, Armin Lambrecht, Jürgen Wöllenstein

    A dual comb spectrometer is used as gas sensor for the parallel detection of nitrous oxide (N2O) and carbon monoxide (CO). These gases have overlapping absorption features in the mid-infrared (MIR) at a wavelength of 4.6 µm. With a spectra acquisition rate of 10 Hz, concentrations of 50 ppm N2O and 30 ppm CO are monitored with a relative precision of 6 × 10 − 3 and 3 × 10 − 3 respectively. The limit of detections are 91 ppb for N2O and 50 ppb for CO for an integration time of 25 s. The system exhibits a linear sensitivity from 2 ppm to 100 ppm with coefficients of determination of 0.99998 for N2O and 0.99996 for CO.


  • Open Access

    Diamond-Coated Silicon ATR Elements for Process Analytics

    by Nicolai Arndt, Carsten Bolwien, Gerd Sulz, Frank Kühnemann, Armin Lambrecht

    Infrared attenuated total reflection (ATR) spectroscopy is a common laboratory technique for the analysis of highly absorbing liquids or solid samples. However, ATR spectroscopy is rarely found in industrial processes, where inline measurement, continuous operation, and minimal maintenance are important issues. Most materials for mid-infrared (MIR) spectroscopy and specifically for ATR elements do not have either high enough infrared transmission or sufficient mechanical and chemical stability to be exposed to process fluids, abrasive components, and aggressive cleaning agents. Sapphire is the usual choice for infrared wavelengths below 5 µm, and beyond that, only diamond is an established material. The use of diamond coatings on other ATR materials such as silicon will increase the stability of the sensor and will enable the use of larger ATR elements with increased sensitivity at lower cost for wavelengths above 5 µm. Theoretical and experimental investigations of the dependence of ATR absorbances on the incidence angle and thickness of nanocrystalline diamond (NCD) coatings on silicon were performed. By optimizing the coating thickness, a substantial amplification of the ATR absorbance can be achieved compared to an uncoated silicon element. Using a compact FTIR instrument, ATR spectra of water, acetonitrile, and propylene carbonate were measured with planar ATR elements made of coated and uncoated silicon. Compared to sapphire, the long wavelength extreme of the spectral range is extended to approximately 8 μm. With effectively nine ATR reflections, the sensitivity is expected to exceed the performance of typical diamond tip probes.


  • Open Access

    Cylindrical IR-ATR Sensors for Process Analytics

    by Armin Lambrecht, Carsten Bolwien, Jochen Erb, Hendrik Fuhr, Gerd Sulz

    Infrared attenuated total reflection (ATR) spectroscopy is a common laboratory technique for the analysis of highly absorbing liquids and solids. However, in a process environment, maintaining a sufficient sample exchange and cleaning of the sensitive surface of the element is a crucial issue. An important industrial application is the measurement of isocyanate concentrations. Isocyanates are necessary for the fabrication of polyurethane materials and are among the chemicals with the highest production volume worldwide. For process applications, narrowband photometers or MEMS spectrometers are more appropriate than the use of bulky FTIR instruments frequently encountered in a laboratory environment. Toluene diisocyanate (TDI) and hexamethylene diisocyanate (HDI) concentrations are measured with a planar ATR photometer setup. Using a miniature Fabry–Perot interferometer (FPI), trace concentrations below 100 ppm (m/m) are detected. By employing an ATR element of the cylindrical shape, sensors can be realized with a smooth surface ideally suited for an automatic cleaning system in a process environment. A laboratory setup with sapphire tubes as ATR elements for incorporation in a liquid flow system is described. Reflection and transmission configurations were investigated. Measurements with acetonitrile as a less toxic substitute showed that with cylindrical ATR sensors’ detection limits for isocyanate concentrations below 100 ppm (m/m) are feasible.


  • Remote detection of leakages of non-IR-active gases by laser spectroscopy

    by Sven Rademacher, Johannes Herbst, Armin Lambrecht, Thomas Strahl, Eric Maier

    Remote leak detection of gases such as the homonuclear molecules (N2, H2, etc.) and noble gases (He, Ar etc.) is still an issue for tunable laser spectroscopy (TLS) because these gases do not have infrared absorption bands. In order to detect a leak in air, the gas displacement of the ambient air is used as an indirect indication of the leak. So, the unique idea is to measure the reduced oxygen concentration by a standoff laser spectrometer at an emission wavelength of 761 nm. The advantage of oxygen as indicator gas is the stable concentration level with respect to low spatial and temporal fluctuations. The challenge of the standoff detection is to analyze the small relative transmission change for weak light intensity scattered by the background. Furthermore, a remote measurement technique for high-level oxygen concentration on ppm level resolution is demonstrated. Here the combination of a high performance distributed feedback laser at 761 nm and high end sophisticated electronics for driver and data acquisition is required and designed. With the direct absorption spectroscopy, the concentration change of 2000 ppm within a 1 cm plume size (10 ml/min flow, ambient room conditions) corresponds to a transmission change in order of 2E-4 has been resolved on a low absolute power level of few micro watts in 1m distance. The detection limit corresponds to a nitrogen leakage rate of 0.1mbar·l/s which is comparable to ordinary remote detection systems for methane leakages.

  • Open Access

    Gas Leak Detection by Dilution of Atmospheric Oxygen

    by Armin Lambrecht, Eric Maier, Hans-Fridtjof Pernau, Thomas Strahl, Johannes Herbst

    Gas leak detection is an important issue in infrastructure monitoring and industrial production. In this context, infrared (IR) absorption spectroscopy is a major measurement method. It can be applied in an extractive or remote detection scheme. Tunable laser spectroscopy (TLS) instruments are able to detect CH4 leaks with column densities below 10 ppm·m from a distance of 30 m in less than a second. However, leak detection of non-IR absorbing gases such as N2 is not possible in this manner. Due to the fact that any leaking gas displaces or dilutes the surrounding background gas, an indirect detection is still possible. It is shown by sensitive TLS measurements of the ambient background concentration of O2 that N2 leaks can be localized with extractive and standoff methods for distances below 1 m. Minimum leak rates of 0.1 mbar·L/s were determined. Flow simulations confirm that the leakage gas typically effuses in a narrow jet. The sensitivity is mainly determined by ambient flow conditions. Compared to TLS detection of CH4 at 1651 nm, the indirect method using O2 at 761 nm is experimentally found to be less sensitive by a factor of 100. However, the well-established TLS of O2 may become a universal tool for rapid leakage screening of vessels that contain unknown or inexpensive gases, such as N2.


  • Neue Methoden der laserbasierten Gasanalytik

    by Armin Lambrecht, Carsten Bolwien, Johannes Herbst, Frank Kühnemann, Vincenz Sandfort, Sebastian Wolf

    Laser haben durch die Fortschritte in der Herstellung, Qualität und breiten Anwendbarkeit erfolgreich Einzug die optische Online‐ und Inline‐Prozessanalysentechnik gehalten. Es wird gezeigt, welche Möglichkeiten sich durch den Einsatz von laserbasierten Methoden für die Gasanalytik ergeben. Dies wird anhand von Beispielen aus der Infrarotspektroskopie und Raman‐Spektroskopie demonstriert. Mit der Raman‐Spektroskopie in hohlen photonischen Kristallfasern lassen sich geringe Gaskonzentrationen mit Messzeiten im Sekundenbereich detektieren. Mit Quantenkaskadenlasern können Methanemissionen im Spurenbereich aus der Ferne nachgewiesen werden und mithilfe von Lasern und nichtlinear‐optischen Komponenten lassen sich hochempfindliche ungekühlte Infrarotdetektoren für die Gasanalyse realisieren.