Stephen F. Keevil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Stephen F. Keevil has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- David John Lomas
Department of Radiology University of Cambridge Cambridge United Kingdom
2 shared publications - Adam Peter Shortland
Paediatric Neurosciences Guy’s and St Thomas’ Foundation NHS Trust Evelina Children’s Hospital London UK
1 shared publication - Ana Pascoal
King's Technology Evaluation Centre (KiTEC), King's College London, London, UK
1 shared publication - Andrew P Lewis
One Small Step Gait Laboratory, Guy’s and St Thomas’ NHS Foundation Trust, Guy’s Hospital, London SE1 9RT, United Kingdom
1 shared publication - Ashley Catterall
Ross-on-Wye, UK
1 shared publication - Cornelius A Lewis
King's Technology Evaluation Centre (KiTEC), King's College London, London, UK
1 shared publication
Latest Publications
- Open Access
- 26 January 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1070) , 20160813
The Control of Electromagnetic Fields at Work Regulations 2016 and medical MRI
This short commentary provides the MRI community in the UK with practical advice on the impact of the Control of Electromagnetic Fields at Work Regulations 2016 in clinical and research settings. The regulations are the UK implementation of the European Union Physical Agents (Electromagnetic Fields) Directive, which has been the subject of much discussion and concern over the past 13 years. However, thanks to concessions achieved through negotiation, and sensible and proportionate transposition into UK law by the Health and Safety Executive, the negative consequences that were foreseen have been averted. MRI activities are exempt from the occupational exposure limits contained in the regulations, subject to meeting certain conditions. The commentary gives advice on compliance with these conditions and on how to satisfy the other requirements of the regulations, all of which are either already required under existing legislation or represent good MR safety practice.
- 26 January 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1070) , 20160813
Open AccessThe Control of Electromagnetic Fields at Work Regulations 2016 and medical MRI
This short commentary provides the MRI community in the UK with practical advice on the impact of the Control of Electromagnetic Fields at Work Regulations 2016 in clinical and research settings. The regulations are the UK implementation of the European Union Physical Agents (Electromagnetic Fields) Directive, which has been the subject of much discussion and concern over the past 13 years. However, thanks to concessions achieved through negotiation, and sensible and proportionate transposition into UK law by the Health and Safety Executive, the negative consequences that were foreseen have been averted. MRI activities are exempt from the occupational exposure limits contained in the regulations, subject to meeting certain conditions. The commentary gives advice on compliance with these conditions and on how to satisfy the other requirements of the regulations, all of which are either already required under existing legislation or represent good MR safety practice.
- 1 September 2016
- Published by IOP Publishing in Physics World
- Vol. 29 (9) , 27-28
Varying views on Brexit
In reply to coverage of the referendum on UK membership in the EU.
- 1 September 2016
- Published by IOP Publishing in Physics World
- Vol. 29 (9) , 27-28
Varying views on Brexit
In reply to coverage of the referendum on UK membership in the EU.
- 1 September 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1065) , 20160376
Selecting a CT scanner for cardiac imaging: the heart of the matter
Coronary angiography to assess the presence and degree of arterial stenosis is an examination now routinely performed on CT scanners. Although developments in CT technology over recent years have made great strides in improving the diagnostic accuracy of this technique, patients with certain characteristics can still be ‘difficult to image’. The various groups will benefit from different technological enhancements depending on the type of challenge they present. Good temporal and spatial resolution, wide longitudinal (z-axis) detector coverage and high x-ray output are the key requirements of a successful CT coronary angiography (CTCA) scan. The requirement for optimal patient dose is a given. The different scanner models recommended for CTCA all excel in different aspects. The specification data presented here for these scanners and the explanation of the impact of the different features should help in making a more informed decision when selecting a scanner for CTCA.
- 1 September 2016
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 89 (1065) , 20160376
Selecting a CT scanner for cardiac imaging: the heart of the matter
Coronary angiography to assess the presence and degree of arterial stenosis is an examination now routinely performed on CT scanners. Although developments in CT technology over recent years have made great strides in improving the diagnostic accuracy of this technique, patients with certain characteristics can still be ‘difficult to image’. The various groups will benefit from different technological enhancements depending on the type of challenge they present. Good temporal and spatial resolution, wide longitudinal (z-axis) detector coverage and high x-ray output are the key requirements of a successful CT coronary angiography (CTCA) scan. The requirement for optimal patient dose is a given. The different scanner models recommended for CTCA all excel in different aspects. The specification data presented here for these scanners and the explanation of the impact of the different features should help in making a more informed decision when selecting a scanner for CTCA.
- Open Access
- 12 July 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 236
Intramuscular fat in ambulant young adults with bilateral spastic cerebral palsy
It is known that individuals with bilateral spastic cerebral palsy (BSCP) have small and weak muscles. However, no studies to date have investigated intramuscular fat infiltration in this group. The objective of this study is to determine whether adults with BSCP have greater adiposity in and around their skeletal muscles than their typically developing (TD) peers as this may have significant functional and cardio-metabolic implications for this patient group.
- 12 July 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 236
Open AccessIntramuscular fat in ambulant young adults with bilateral spastic cerebral palsy
It is known that individuals with bilateral spastic cerebral palsy (BSCP) have small and weak muscles. However, no studies to date have investigated intramuscular fat infiltration in this group. The objective of this study is to determine whether adults with BSCP have greater adiposity in and around their skeletal muscles than their typically developing (TD) peers as this may have significant functional and cardio-metabolic implications for this patient group.
- Open Access
- 1 December 2013
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 86 (1032) , 20130492
The European Union physical agents (electromagnetic fields) directive: an update for the MRI community
- 1 December 2013
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 86 (1032) , 20130492
Open AccessThe European Union physical agents (electromagnetic fields) directive: an update for the MRI community
- 1 April 2012
- Published by Elsevier in The Lancet
- Vol. 379 (9825) , 1517-1524
Physics and medicine: a historical perspective
- 1 April 2012
- Published by Elsevier in The Lancet
- Vol. 379 (9825) , 1517-1524
Physics and medicine: a historical perspective
- 1 October 2010
- Published by Elsevier in The Lancet
- Vol. 376 (9747) , 1124-1125
EMF directive still poses a risk to MRI research in Europe
- 1 October 2010
- Published by Elsevier in The Lancet
- Vol. 376 (9747) , 1124-1125
EMF directive still poses a risk to MRI research in Europe
- 1 September 2009
- Published by IOP Publishing in Physics World
- Vol. 22 (09) , 21
Medical imaging at risk from European directive
The recent Forum article by Denis Le Bihan ("Threats to ultra-high-field MRI" August pp16–17) is a valuable addition to the ongoing debate about the impact on magnetic resonance imaging (MRI) of the European Commission's Physical Agents (EMF) directive. When this directive was introduced in 2004, exposure limits for static magnetic fields were excluded, because it was known that guidance published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) in 1994 was being revised. It is likely that the new ICNIRP guidelines, to which Le Bihan refers, will now be incorporated into the directive. If so, this could indeed impact on ultra-highfield MRI, in which Europe has a worldleading position.
- 1 September 2009
- Published by IOP Publishing in Physics World
- Vol. 22 (09) , 21
Medical imaging at risk from European directive
The recent Forum article by Denis Le Bihan ("Threats to ultra-high-field MRI" August pp16–17) is a valuable addition to the ongoing debate about the impact on magnetic resonance imaging (MRI) of the European Commission's Physical Agents (EMF) directive. When this directive was introduced in 2004, exposure limits for static magnetic fields were excluded, because it was known that guidance published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) in 1994 was being revised. It is likely that the new ICNIRP guidelines, to which Le Bihan refers, will now be incorporated into the directive. If so, this could indeed impact on ultra-highfield MRI, in which Europe has a worldleading position.
- 26 July 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (16) , R579-R636
Spatial localization in nuclear magnetic resonance spectroscopy
The ability to select a discrete region within the body for signal acquisition is a fundamental requirement of in vivo NMR spectroscopy. Ideally, it should be possible to tailor the selected volume to coincide exactly with the lesion or tissue of interest, without loss of signal from within this volume or contamination with extraneous signals. Many techniques have been developed over the past 25 years employing a combination of RF coil properties, static magnetic field gradients and pulse sequence design in an attempt to meet these goals. This review presents a comprehensive survey of these techniques, their various advantages and disadvantages, and implications for clinical applications. Particular emphasis is placed on the reliability of the techniques in terms of signal loss, contamination and the effect of nuclear relaxation and J-coupling. The survey includes techniques based on RF coil and pulse design alone, those using static magnetic field gradients, and magnetic resonance spectroscopic imaging. Although there is an emphasis on techniques currently in widespread use (PRESS, STEAM, ISIS and MRSI), the review also includes earlier techniques, in order to provide historical context, and techniques that are promising for future use in clinical and biomedical applications.
- 26 July 2006
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (16) , R579-R636
Spatial localization in nuclear magnetic resonance spectroscopy
The ability to select a discrete region within the body for signal acquisition is a fundamental requirement of in vivo NMR spectroscopy. Ideally, it should be possible to tailor the selected volume to coincide exactly with the lesion or tissue of interest, without loss of signal from within this volume or contamination with extraneous signals. Many techniques have been developed over the past 25 years employing a combination of RF coil properties, static magnetic field gradients and pulse sequence design in an attempt to meet these goals. This review presents a comprehensive survey of these techniques, their various advantages and disadvantages, and implications for clinical applications. Particular emphasis is placed on the reliability of the techniques in terms of signal loss, contamination and the effect of nuclear relaxation and J-coupling. The survey includes techniques based on RF coil and pulse design alone, those using static magnetic field gradients, and magnetic resonance spectroscopic imaging. Although there is an emphasis on techniques currently in widespread use (PRESS, STEAM, ISIS and MRSI), the review also includes earlier techniques, in order to provide historical context, and techniques that are promising for future use in clinical and biomedical applications.
- 1 April 2003
- Published by IOP Publishing in Physics World
- Vol. 16 (4) , 17
The bottom line with top-up fees
As your news story reports (February p9), from 2006 universities in England will be allowed to charge tuition fees of anything up to £3000 per year, compared with the flat rate of just £1100 for all subjects now. Imposing higher fees is often justified on the grounds that graduates earn substantially more than non-graduates over their working lives – and should therefore pay more for their education than they do now. Meanwhile, people who are in favour of differential fees argue that graduates from some institutions and courses earn substantially more than those from others.
- 1 April 2003
- Published by IOP Publishing in Physics World
- Vol. 16 (4) , 17
The bottom line with top-up fees
As your news story reports (February p9), from 2006 universities in England will be allowed to charge tuition fees of anything up to £3000 per year, compared with the flat rate of just £1100 for all subjects now. Imposing higher fees is often justified on the grounds that graduates earn substantially more than non-graduates over their working lives – and should therefore pay more for their education than they do now. Meanwhile, people who are in favour of differential fees argue that graduates from some institutions and courses earn substantially more than those from others.