KOKazuhiko Oka

Kazuhiko Oka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kazuhiko Oka has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Picosecond rotation of a ring-shaped optical lattice by using a chirped vortex-pulse pair

    by K. Yamane, M. Sakamoto, N. Murakami, R. Morita, K. Oka

    A novel method of ultrafast rotation of a ring-shaped optical lattice in the picosecond time region was proposed and demonstrated. Our ring-lattice generator was assembled by a pair of linearly chirped pulses with a time delay, a high-order birefringent retarder, and an axially symmetric polarization element. Using a mode-locked Ti:sapphire laser oscillator as a light source, stable two-, four-, and six-petaled ring-lattice rotations were demonstrated with the rotation periods of 1.6, 3.2, and 4.8 ps, respectively. Our method has the potential to open up a new technique to resonantly excite propagating quasi-particles together with their coherent enhancement.


  • Modeling and optimization for a prismatic snapshot imaging polarimeter

    by Haitao Luo, Kazuhiko Oka, Nathan Hagen, Tomasz Tkaczyk, Eustace L. Dereniak

    Thin birefringent prisms placed near an image plane introduce sinusoidal fringes onto a 2D polarized scene making possible a snapshot imaging polarimeter, which encodes polarization information into the modulation of the fringes. This approach was introduced by Oka and Kaneko [Opt. Express 11, 1510 (2003)], who analyzed the instrument through the Mueller calculus. We show that the plane-wave assumption adopted in the Mueller theory can introduce unnecessary error in a polarimeter design. To directly take prism effects such as beam splitting and deviating into accounts we introduce a geometric imaging model, which allows for a versatile simulation of the birefringent prisms and provides a means for optimization. A calcite visible system is investigated as an example, which essentially shows how each design parameter affects the overall image quality and how to modify the polarimeter design to optimize overall performance. The approach is applicable to any prismatic imaging polarimeter with different prism materials and different working wavelengths.


  • Spectroscopic polarimetry with a channeled spectrum

    by Kazuhiko Oka, Takayuki Kato

    We describe a novel method for the spectroscopic measurement of the state of polarization (SOP) of light. A pair of thick birefringent retarders is incorporated into the spectroscopic polarimeter, so the generated channeled spectrum is composed of three quasi-cosinusoidal components carrying the information about the SOP of the light that is being measured. Fourier inversion of the channeled spectrum provides significant parameters for determination of the spectrally resolved Stokes parameters of light. No mechanically movable components for polarization control or active devices for polarization modulation are used, and all the Stokes parameters can be determined at once from only the single spectrum. The effectiveness of this method is demonstrated by the generation of elliptically polarized light whose SOP varies with wave number.