Oliver Pänke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Oliver Pänke has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Anja Steude
Centre for Biotechnology and Biomedicine (BBZ), University of Leipzig, Division of Molecular Biological-Biochemical Processing Technology, Deutscher Platz 5, D-04103 Leipzig, Germany
2 shared publicationsSabine Schmidt
Centre for Biotechnology and Biomedicine (BBZ), University of Leipzig, Division of Molecular Biological-Biochemical Processing Technology, Deutscher Platz 5, Leipzig, Germany
2 shared publicationsAndrea A. Robitzki
Centre for Biotechnology and Biomedicine (BBZ), University of Leipzig, Division of Molecular Biological-Biochemical Processing Technology, Deutscher Platz 5, D-04103 Leipzig, Germany
1 shared publication- Andrea A. Robitzki
Centre for Biotechnology and Biomedicine (BBZ), Universität Leipzig, Division of Molecular Biological-Biochemical Processing Technology, Deutscher Platz 5, 04103, Leipzig, Germany.
1 shared publication Winnie Weigel
Centre for Biotechnology and Biomedicine (BBZ), University of Leipzig, Division of Molecular Biological-Biochemical Processing Technology, Deutscher Platz 5, D-04103 Leipzig, Germany
1 shared publication
Latest Publications
- 13 July 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (17) , 2884-2892
An electrode array for electrochemical immuno-sensing using the example of impedimetric tenascin C detection
Electrochemical biosensors allow simple, fast and sensitive analyte detection for various analytical problems. Especially immunosensors are favourable due to specificity and affinity of antigen recognition by the associated antibody. We present a novel electrode array qualified for parallel analysis and increased sample throughput. The chip has nine independent sample chambers. Each chamber contains a circular gold working electrode with a diameter of 1.9 mm that is surrounded by a ring-shaped auxiliary electrode with a platinum surface. The corresponding silver/silver chloride reference electrodes are embedded in a sealing lid. The chip is open to the full range of electrochemical real-time detection methods. Among these techniques, impedance spectroscopy is an attractive tool to detect fast and label-free interfacial changes originating from the biorecognition event at the electrode surface. The capabilities of the novel electrode array are demonstrated using the example of tumour marker tenascin C detection. This glycoprotein of the extracellular matrix is expressed in cancerous tissues, especially in solid tumours such as glioma or breast carcinoma. Electrodes covered with specific antibodies were exposed to tenascin C containing samples. Non-occupied binding sites were identified using a secondary peroxidase-conjugated antibody that generated an insoluble precipitate on the electrode in a subsequent amplification procedure. The charge transfer resistance obtained from impedimetric analysis of ferri-/ferrocyanide conversion at the electrode served as analytic parameter. This assay detected 14 ng (48 fmol) tenascin C that is sufficient for clinical diagnostics. The electrode surface could be regenerated at least 20-fold without loss of its analytical performance.
- 13 July 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (17) , 2884-2892
An electrode array for electrochemical immuno-sensing using the example of impedimetric tenascin C detection
Electrochemical biosensors allow simple, fast and sensitive analyte detection for various analytical problems. Especially immunosensors are favourable due to specificity and affinity of antigen recognition by the associated antibody. We present a novel electrode array qualified for parallel analysis and increased sample throughput. The chip has nine independent sample chambers. Each chamber contains a circular gold working electrode with a diameter of 1.9 mm that is surrounded by a ring-shaped auxiliary electrode with a platinum surface. The corresponding silver/silver chloride reference electrodes are embedded in a sealing lid. The chip is open to the full range of electrochemical real-time detection methods. Among these techniques, impedance spectroscopy is an attractive tool to detect fast and label-free interfacial changes originating from the biorecognition event at the electrode surface. The capabilities of the novel electrode array are demonstrated using the example of tumour marker tenascin C detection. This glycoprotein of the extracellular matrix is expressed in cancerous tissues, especially in solid tumours such as glioma or breast carcinoma. Electrodes covered with specific antibodies were exposed to tenascin C containing samples. Non-occupied binding sites were identified using a secondary peroxidase-conjugated antibody that generated an insoluble precipitate on the electrode in a subsequent amplification procedure. The charge transfer resistance obtained from impedimetric analysis of ferri-/ferrocyanide conversion at the electrode served as analytic parameter. This assay detected 14 ng (48 fmol) tenascin C that is sufficient for clinical diagnostics. The electrode surface could be regenerated at least 20-fold without loss of its analytical performance.
- 1 January 2011
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 26 (5) , 2376-2382
A cell-based impedance assay for monitoring transient receptor potential (TRP) ion channel activity
- 1 January 2011
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 26 (5) , 2376-2382
A cell-based impedance assay for monitoring transient receptor potential (TRP) ion channel activity