Dorothea Pfeiffer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dorothea Pfeiffer has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Richard Hall-Wilton
European Spallation Source (ESS AB P.O. Box 176 SE-22100 Lund Sweden
3 shared publicationsC. Höglund
European Spallation Source (ESS AB), P.O. Box 176, SE-22100 Lund, Sweden
2 shared publicationsCarina Höglund
European Spallation Source (ESS AB P.O. Box 176 SE-22100 Lund Sweden
2 shared publicationsE. Oksanen
European Spallation Source (ESS AB), P.O. Box 176, SE-22100 Lund, Sweden
2 shared publicationsEraldo Oliveri
CERN CH 1211 Geneva 23 Switzerland
2 shared publicationsEsko Oksanen
European Spallation Source (ESS AB P.O. Box 176 SE-22100 Lund Sweden
2 shared publications
Latest Publications
- Open Access
Interfacing Geant4, Garfield++ and Degrad for the Simulation of Gaseous Detectors
For several years, attempts have been made to interface Geant4 and other software packages with the aim of simulating the complete response of a gaseous particle detector. In such a simulation, Geant4 is always responsible for the primary particle generation and the interactions that occur in the non-gaseous detector material. Garfield++ on the other hand always deals with the drift of ions and electrons, amplification via electron avalanches and finally signal generation. For the ionizing interaction of particles with the gas, different options and physics models exist. The present paper focuses on how to use Geant4, Garfield++ (including its Heed and SRIM interfaces) and Degrad to create the ionization electron-ion pairs in the gas. Software-wise, the proposed idea is to use the Geant4 physics parameterization feature, and to implement a Garfield++ or Degrad based detector simulation as an external model. With a Degrad model, detailed simulations of the X-ray interaction in gaseous detectors, including shell absorption by photoelectric effect, subsequent Auger cascade, shake-off and fluorescence emission, become possible. A simple Garfield++ model can be used for photons (Heed), heavy ions (SRIM) and relativistic charged particles or MIPs (Heed). For non-relativistic charged particles, more effort is required, and a combined Geant4/Garfield++ model must be used. This model, the Geant4/Heed PAI model interface, uses the Geant4 PAI model in conjunction with the Heed PAI model. Parameters, such as the lower production cut of the Geant4 PAI model and the lowest electron energy limit have to be set correctly. The paper demonstrates how to determine these parameters for certain values of the W parameter and Fano factor of the gas mixture. The simulation results of this Geant4/Heed PAI model interface are then verified against the results obtained with the stand-alone software packages.
Open AccessInterfacing Geant4, Garfield++ and Degrad for the Simulation of Gaseous Detectors
For several years, attempts have been made to interface Geant4 and other software packages with the aim of simulating the complete response of a gaseous particle detector. In such a simulation, Geant4 is always responsible for the primary particle generation and the interactions that occur in the non-gaseous detector material. Garfield++ on the other hand always deals with the drift of ions and electrons, amplification via electron avalanches and finally signal generation. For the ionizing interaction of particles with the gas, different options and physics models exist. The present paper focuses on how to use Geant4, Garfield++ (including its Heed and SRIM interfaces) and Degrad to create the ionization electron-ion pairs in the gas. Software-wise, the proposed idea is to use the Geant4 physics parameterization feature, and to implement a Garfield++ or Degrad based detector simulation as an external model. With a Degrad model, detailed simulations of the X-ray interaction in gaseous detectors, including shell absorption by photoelectric effect, subsequent Auger cascade, shake-off and fluorescence emission, become possible. A simple Garfield++ model can be used for photons (Heed), heavy ions (SRIM) and relativistic charged particles or MIPs (Heed). For non-relativistic charged particles, more effort is required, and a combined Geant4/Garfield++ model must be used. This model, the Geant4/Heed PAI model interface, uses the Geant4 PAI model in conjunction with the Heed PAI model. Parameters, such as the lower production cut of the Geant4 PAI model and the lowest electron energy limit have to be set correctly. The paper demonstrates how to determine these parameters for certain values of the W parameter and Fano factor of the gas mixture. The simulation results of this Geant4/Heed PAI model interface are then verified against the results obtained with the stand-alone software packages.
- Open Access
The radiation field in the Gamma Irradiation Facility GIF++ at CERN
The high-luminosity LHC (HL-LHC) upgrade is setting now a new challenge for particle detector technologies. The increase in luminosity will produce a particle background in the gas-based muon detectors that is ten times higher than under conditions at the LHC. The detailed knowledge of the detector performance in the presence of such a high background is crucial for an optimized design and efficient operation after the HL-LHC upgrade. A precise understanding of possible aging effects of detector materials and gases is of extreme importance. To cope with these challenging requirements, a new Gamma Irradiation Facility (GIF++) was designed and built at the CERN SPS North Area as successor of the Gamma Irradiation Facility (GIF) during the Long Shutdown 1 (LS1) period. It features an intense source of 662 keV photons with adjustable intensity, to simulate continuous background over large areas, and, combined with a high energy muon beam, to measure detector performance in the presence of the background. The new GIF++ facility has been operational since spring 2015. In addition to describing the facility and its infrastructure, the goal of this work is to provide an extensive characterization of the GIF++ photon field with different configurations of the absorption filters in both the upstream and downstream irradiation areas. Moreover, the measured results are benchmarked with Geant4 simulations to enhance the knowledge of the radiation field. The absorbed dose in air in the facility may reach up to 2.2 Gy/h directly in front of the irradiator. Of special interest is the low-energy photon component that develops due to the multiple scattering of photons within the irradiator and from the concrete walls of the bunker.
Open AccessThe radiation field in the Gamma Irradiation Facility GIF++ at CERN
The high-luminosity LHC (HL-LHC) upgrade is setting now a new challenge for particle detector technologies. The increase in luminosity will produce a particle background in the gas-based muon detectors that is ten times higher than under conditions at the LHC. The detailed knowledge of the detector performance in the presence of such a high background is crucial for an optimized design and efficient operation after the HL-LHC upgrade. A precise understanding of possible aging effects of detector materials and gases is of extreme importance. To cope with these challenging requirements, a new Gamma Irradiation Facility (GIF++) was designed and built at the CERN SPS North Area as successor of the Gamma Irradiation Facility (GIF) during the Long Shutdown 1 (LS1) period. It features an intense source of 662 keV photons with adjustable intensity, to simulate continuous background over large areas, and, combined with a high energy muon beam, to measure detector performance in the presence of the background. The new GIF++ facility has been operational since spring 2015. In addition to describing the facility and its infrastructure, the goal of this work is to provide an extensive characterization of the GIF++ photon field with different configurations of the absorption filters in both the upstream and downstream irradiation areas. Moreover, the measured results are benchmarked with Geant4 simulations to enhance the knowledge of the radiation field. The absorbed dose in air in the facility may reach up to 2.2 Gy/h directly in front of the irradiator. Of special interest is the low-energy photon component that develops due to the multiple scattering of photons within the irradiator and from the concrete walls of the bunker.
- Open Access
First Measurements with New High-Resolution Gadolinium-GEM Neutron Detectors
European Spallation Source instruments like the macromolecular diffractometer, NMX, require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few hundred micrometers over a wide angular range of the incoming neutrons. For these instruments solid converters in combination with Micro Pattern Gaseous Detectors (MPGDs) are a promising option. A GEM detector with gadolinium converter was tested on a cold neutron beam at the IFE research reactor in Norway. The {\mu}TPC analysis, proven to improve the spatial resolution in the case of $^{10}$B converters, is extended to gadolinium based detectors. For the first time, a Gd-GEM was successfully operated to detect neutrons with a measured efficiency of 11.8% at a wavelength of 2 {\AA} and a position resolution better than 250 {\mu}m.
Open AccessFirst Measurements with New High-Resolution Gadolinium-GEM Neutron Detectors
European Spallation Source instruments like the macromolecular diffractometer, NMX, require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few hundred micrometers over a wide angular range of the incoming neutrons. For these instruments solid converters in combination with Micro Pattern Gaseous Detectors (MPGDs) are a promising option. A GEM detector with gadolinium converter was tested on a cold neutron beam at the IFE research reactor in Norway. The {\mu}TPC analysis, proven to improve the spatial resolution in the case of $^{10}$B converters, is extended to gadolinium based detectors. For the first time, a Gd-GEM was successfully operated to detect neutrons with a measured efficiency of 11.8% at a wavelength of 2 {\AA} and a position resolution better than 250 {\mu}m.
- Open Access
- 1 May 2016
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 11 (05) , P05011
First measurements with new high-resolution gadolinium-GEM neutron detectors
European Spallation Source instruments like the macromolecular diffractometer (NMX) require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few hundred micrometers over a wide angular range of the incoming neutrons. For these instruments solid converters in combination with Micro Pattern Gaseous Detectors (MPGDs) are a promising option. A GEM detector with gadolinium converter was tested on a cold neutron beam at the IFE research reactor in Norway. The µTPC analysis, proven to improve the spatial resolution in the case of 10 B converters, is extended to gadolinium based detectors. For the first time, a Gd-GEM was successfully operated to detect neutrons with a measured efficiency of 11.8% at a wavelength of 2 Å and a position resolution better than 250 µm.
- 1 May 2016
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 11 (05) , P05011
Open AccessFirst measurements with new high-resolution gadolinium-GEM neutron detectors
European Spallation Source instruments like the macromolecular diffractometer (NMX) require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few hundred micrometers over a wide angular range of the incoming neutrons. For these instruments solid converters in combination with Micro Pattern Gaseous Detectors (MPGDs) are a promising option. A GEM detector with gadolinium converter was tested on a cold neutron beam at the IFE research reactor in Norway. The µTPC analysis, proven to improve the spatial resolution in the case of 10 B converters, is extended to gadolinium based detectors. For the first time, a Gd-GEM was successfully operated to detect neutrons with a measured efficiency of 11.8% at a wavelength of 2 Å and a position resolution better than 250 µm.
- Open Access
- 3 July 2015
- Published by Sissa Medialab Srl
- Vol. 213, 102
CERN-GIF++: a new irradiation facility to test large-area particle detectors for the high-luminosity LHC program
- 3 July 2015
- Published by Sissa Medialab Srl
- Vol. 213, 102
Open AccessCERN-GIF++: a new irradiation facility to test large-area particle detectors for the high-luminosity LHC program
- Open Access
- 1 April 2015
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 10 (04) , P04004
The μTPC method: improving the position resolution of neutron detectors based on MPGDs
- 1 April 2015
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 10 (04) , P04004
Open AccessThe μTPC method: improving the position resolution of neutron detectors based on MPGDs
- Open Access
The uTPC Method: Improving the Position Resolution of Neutron Detectors Based on MPGDs
Due to the Helium-3 crisis, alternatives to the standard neutron detection techniques are becoming urgent. In addition, the instruments of the European Spallation Source (ESS) require advances in the state of the art of neutron detection. The instruments need detectors with excellent neutron detection efficiency, high-rate capabilities and unprecedented spatial resolution. The Macromolecular Crystallography instrument (NMX) requires a position resolution in the order of 200 um over a wide angular range of incoming neutrons. Solid converters in combination with Micro Pattern Gaseous Detectors (MPGDs) are proposed to meet the new requirements. Charged particles rising from the neutron capture have usually ranges larger than several millimetres in gas. This is apparently in contrast with the requirements for the position resolution. In this paper, we present an analysis technique, new in the field of neutron detection, based on the Time Projection Chamber (TPC) concept. Using a standard Single-GEM with the cathode coated with 10B4C, we extract the neutron interaction point with a resolution of better than sigma = 200 um.
Open AccessThe uTPC Method: Improving the Position Resolution of Neutron Detectors Based on MPGDs
Due to the Helium-3 crisis, alternatives to the standard neutron detection techniques are becoming urgent. In addition, the instruments of the European Spallation Source (ESS) require advances in the state of the art of neutron detection. The instruments need detectors with excellent neutron detection efficiency, high-rate capabilities and unprecedented spatial resolution. The Macromolecular Crystallography instrument (NMX) requires a position resolution in the order of 200 um over a wide angular range of incoming neutrons. Solid converters in combination with Micro Pattern Gaseous Detectors (MPGDs) are proposed to meet the new requirements. Charged particles rising from the neutron capture have usually ranges larger than several millimetres in gas. This is apparently in contrast with the requirements for the position resolution. In this paper, we present an analysis technique, new in the field of neutron detection, based on the Time Projection Chamber (TPC) concept. Using a standard Single-GEM with the cathode coated with 10B4C, we extract the neutron interaction point with a resolution of better than sigma = 200 um.
- Open Access
- 1 August 2011
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 6 (08) , P08005
Design, implementation and first measurements with the Medipix2-MXR detector at the Compact Muon Solenoid experiment
The Medipix detector is the first device dedicated to measuring mixed-field radiation in the CMS (Compact Muon Solenoid) experiment cavern and able to distinguish between different particle types. Medipix2-MXR chips bump bonded to silicon sensors with various neutron conversion layers developed by the IEAP CTU in Prague were successfully installed for the 2008 LHC start-up in the CMS experimental and services caverns to measure the flux of various particle types, in particular neutrons. They have operated almost continuously during the 2010 run period, and the results shown here are from the proton run between the beginning of July and the end of October 2010. Clear signals are seen and different particle types have been observed during regular LHC luminosity running, and an agreement in the measured flux is found with the simulations. These initial results are promising, and indicate that these devices have the potential for further and future LHC and high energy physics applications as radiation monitoring devices for mixed field environments, including neutron flux monitoring. Further extensions are foreseen in the near future to increase the performance of the detector and its coverage for monitoring in CMS.
- 1 August 2011
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 6 (08) , P08005
Open AccessDesign, implementation and first measurements with the Medipix2-MXR detector at the Compact Muon Solenoid experiment
The Medipix detector is the first device dedicated to measuring mixed-field radiation in the CMS (Compact Muon Solenoid) experiment cavern and able to distinguish between different particle types. Medipix2-MXR chips bump bonded to silicon sensors with various neutron conversion layers developed by the IEAP CTU in Prague were successfully installed for the 2008 LHC start-up in the CMS experimental and services caverns to measure the flux of various particle types, in particular neutrons. They have operated almost continuously during the 2010 run period, and the results shown here are from the proton run between the beginning of July and the end of October 2010. Clear signals are seen and different particle types have been observed during regular LHC luminosity running, and an agreement in the measured flux is found with the simulations. These initial results are promising, and indicate that these devices have the potential for further and future LHC and high energy physics applications as radiation monitoring devices for mixed field environments, including neutron flux monitoring. Further extensions are foreseen in the near future to increase the performance of the detector and its coverage for monitoring in CMS.
- Open Access
Design, Implementation and First Measurements with the Medipix Neutron Camera in CMS
The Medipix detector is the first device dedicated to measuring mixed-field radiation in the CMS cavern and able to distinguish between different particle types. Medipix2-MXR chips bump bonded to silicon sensors with various neutron conversion layers developed by the IEAP CTU in Prague were successfully installed for the 2008 LHC start-up in the CMS experimental and services caverns to measure the flux of various particle types, in particular neutrons. They have operated almost continuously during the 2010 run period, and the results shown here are from the proton run between the beginning of July and the end of October 2010. Clear signals are seen and different particle types have been observed during regular LHC luminosity running, and an agreement in the measured flux rate is found with the simulations. These initial results are promising, and indicate that these devices have the potential for further and future LHC and high energy physics applications as radiation monitoring devices for mixed field environments, including neutron flux monitoring. Further extensions are foreseen in the near future to increase the performance of the detector and its coverage for monitoring in CMS.
Open AccessDesign, Implementation and First Measurements with the Medipix Neutron Camera in CMS
The Medipix detector is the first device dedicated to measuring mixed-field radiation in the CMS cavern and able to distinguish between different particle types. Medipix2-MXR chips bump bonded to silicon sensors with various neutron conversion layers developed by the IEAP CTU in Prague were successfully installed for the 2008 LHC start-up in the CMS experimental and services caverns to measure the flux of various particle types, in particular neutrons. They have operated almost continuously during the 2010 run period, and the results shown here are from the proton run between the beginning of July and the end of October 2010. Clear signals are seen and different particle types have been observed during regular LHC luminosity running, and an agreement in the measured flux rate is found with the simulations. These initial results are promising, and indicate that these devices have the potential for further and future LHC and high energy physics applications as radiation monitoring devices for mixed field environments, including neutron flux monitoring. Further extensions are foreseen in the near future to increase the performance of the detector and its coverage for monitoring in CMS.