JKJuha Kaikko

Juha Kaikko

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Juha Kaikko has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental evaluation of planar heat pipes with active cooling integration for photovoltaic thermal hot-spot mitigation

    by Rehan Mendis, Falah Alobaid, Juha Kaikko, Jüergen Karl, Jussi Saari, Sami Albakri

  • Open Access

    Novel BECCS implementation integrating chemical looping combustion with oxygen uncoupling and a kraft pulp mill cogeneration plant

    by Jussi Saari, Petteri Peltola, Katja Kuparinen, Juha Kaikko, Ekaterina Sermyagina, Esa Vakkilainen

    Bioenergy with CO2 capture and storage (BECCS) is a promising negative emission technology (NET). When using sustainably produced biomass as fuel, BECCS allows the production of power and heat with negative CO2 emissions. The main technical challenges hindering the deployment of BECCS technologies include energy penalties associated with the capture process. This work evaluates the performance of an advanced CO2 capture technology, chemical looping with oxygen uncoupling (CLOU), replacing a conventional fluidized bed boiler in the power boiler role in a large, modern integrated pulp and paper mill. Results from a MATLAB/Simulink reactor model were incorporated in a plant and integration model developed in a commercial process simulation software to quantify the performance of the CLOU-integrated cogeneration plant. The results show that in this specific application, the typically already low efficiency penalty of CLOU-based carbon capture and storage (CCS) systems could be eliminated entirely, and actually even a very small efficiency gain could be obtained. The highly efficient operation is possible due to the high moisture and hydrogen contents of the biomass and the separation of combustion products and excess air streams in the CLOU process; this provides an opportunity to recover a significant amount of heat by flue gas condensation at a higher temperature level than what is possible in a conventional boiler. Together with abundant low-temperature heat sinks available at the pulp and paper application allows freeing a considerable amount of low-pressure steam for expansion in the condensing turbine. The resulting increase in gross generator output proved enough to not only match, but very slightly exceed the approximately 18 MW parasitic load introduced by the CLOU system in comparison to the conventional boiler.


  • Open Access

    Improving Kraft Pulp Mill Energy Efficiency through Low-Temperature Hydrothermal Carbonization of Biological Sludge

    by Jussi Saari, Ekaterina Sermyagina, Katja Kuparinen, Satu Lipiäinen, Juha Kaikko, Marcelo Hamaguchi, Clara Mendoza-Martinez

    Of the various waste and side streams created in a kraft pulp mill, the biological sludges from the wastewater treatment plant are some of the most problematic to handle. Incineration is becoming a common solution as landfilling is no longer permitted by legislation in many countries, but this is also problematic due to the high moisture content, poor drying characteristics, and high ash content in the solids. This study evaluates the technical potential of mild hydrothermal carbonization (HTC) at 160 °C for 3 h to improve the energy efficiency of on-site incineration as a biosludge handling method. HTC treatment transforms wet organic substrates into a hydrophobic carbonaceous material (hydrochar). The heating value and elemental composition of both the sludge and the hydrochar product were analyzed. Based on this, a hydrothermal carbonization model developed earlier was adjusted for the feedstock, and process integration modelling performed to evaluate the performance impact on the power and heat generation at the mill. The results indicate that if the alternative is combustion in the power boiler, HTC pre-treatment could allow a significant increase in power generation. If the sludge is combusted in the recovery boiler, a practice often avoided in order to not introduce non-process elements to the chemical recovery cycle but sometimes necessary due to, e.g., absence of a power boiler, a much smaller increase is obtained. The increase is smallest if the freed evaporator plant capacity cannot be utilized for increasing the firing liquor dry solids content.


  • Open Access

    Evaluation of the Energy Efficiency Improvement Potential through Back-End Heat Recovery in the Kraft Recovery Boiler

    by Jussi Saari, Ekaterina Sermyagina, Juha Kaikko, Markus Haider, Marcelo Hamaguchi, Esa Vakkilainen

    Sustainability and energy efficiency have become important factors for many industrial processes, including chemical pulping. Recently complex back-end heat recovery solutions have been applied to biomass-fired boilers, lowering stack temperatures and recovering some of the latent heat of the moisture by condensation. Modern kraft recovery boiler flue gas offers still unutilized heat recovery possibilities. Scrubbers have been used, but the focus has been on gas cleaning; heat recovery implementations remain simple. The goal of this study is to evaluate the potential to increase the power generation and efficiency of chemical pulping by improved back-end heat recovery from the recovery boiler. Different configurations of heat recovery schemes and different heat sink options are considered, including heat pumps. IPSEpro simulation software is used to model the boiler and steam cycle of a modern Nordic pulp mill. When heat pumps are used to upgrade some of the recovered low-grade heat, up to +23 MW gross and +16.7 MW net power generation increase was observed when the whole pulp mill in addition to the boiler and steam cycle is considered as heat consumer. Combustion air humidification proved to yield a benefit only when assuming the largest heat sink scenario for the pulp mill.


  • Open Access

    High-Efficiency Bioenergy Carbon Capture Integrating Chemical Looping Combustion with Oxygen Uncoupling and a Large Cogeneration Plant

    by Jussi Saari, Petteri Peltola, Tero Tynjälä, Timo Hyppänen, Juha Kaikko, Esa Vakkilainen

    Bioenergy with CO2 capture and storage (BECCS) is a promising negative emission technology (NET). When using sustainably produced biomass as fuel, BECCS allows the production of power and heat with negative CO2 emissions. The main technical challenges hindering the deployment of BECCS technologies include energy penalties associated with the capture process. This work evaluates the performance of an advanced CO2 capture technology, chemical looping with oxygen uncoupling (CLOU), in conjunction with biomass-fired combined heat and power (CHP) generation. Results from a MATLAB/Simulink reactor model were incorporated in a plant and integration model developed in a commercial process simulation software to quantify the key performance indicators of the CLOU-integrated CHP plant. Both energy and exergy analysis were conducted. The results show a remarkably low efficiency penalty of 0.7% compared to a conventional reference plant, and a high carbon capture efficiency of 97%. The low efficiency penalty is due to the high moisture and hydrogen contents of the biomass, and the separation of combustion products and excess air streams in the CLOU process; these together provide an opportunity to recover a significant amount of heat by flue gas condensation at a higher temperature level than what is possible in a conventional boiler. The condensing heat recovery yields an 18 MW generator power increase (3 MW loss in net power output) for the CLOU plant; in the reference plant with conventional boiler, the same scheme could achieve an increase of 9 MW (generator) and a decrease of 8 MW (net).