AAArild Aamodt

Arild Aamodt

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Arild Aamodt has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • J. Eine

    Biomechanics Laboratory, Department of Orthopaedic Surgery, Trondheim University Hospital, Trondheim - Norway

    3 shared publications
  • E. Andersen

    Biomechanics Laboratory, Department of Orthopaedic Surgery, Trondheim University Hospital, Trondheim - Norway

    2 shared publications
  • O. Schnell Husby

    Biomechanics Laboratory, Department of Orthopaedic Surgery, Trondheim University Hospital, Trondheim - Norway

    2 shared publications
  • P. Benum

    Biomechanics Laboratory, Department of Orthopaedic Surgery, Trondheim University Hospital, Trondheim - Norway

    2 shared publications
  • J. Lund-Larsen

    Biomechanics Laboratory, Department of Orthopaedic Surgery, Trondheim University Hospital, Trondheim - Norway

    1 shared publication
  • J. Lund‐Larsen

    Biomechanics Laboratory, Department of Orthopedic Surgery, Trondheim University Hospital, Trondheim, Norway

    1 shared publication

Latest Publications

  • Open Access

    Documentation of hip prostheses used in NorwayA critical review of the literature from 1996–2000

    by Arild Aamodt, Larz Nordsletten, Leif Havelin, Kari Indrekvam, Stein Erik Utvåg, Krystyna Hviding Sundberg

    We have conducted a systematic review of the scientific literature concerning outcome and clinical effectiveness of prostheses used for primary total hip replacement (THR) in Norway. The study is based on two Health Technology Assessment reports from the UK (Faulkner et al. 1998, Fitzpatrick et al. 1998), reviewing the literature from 1980 to 1995. Using a similar search strategy, we have evaluated the literature from 1996 through 2000. We included 129 scientific and medical publications which were assessed according to a specific appraisal protocol. The majority (72%) were observational studies, whereas only 9% were randomized studies. We could not retrieve any peer-reviewed documentation for one third of the implants. The Charnley prosthesis had by far the best and most comprehensive evidence base with better than 90% implant survival after about 10 years. Survival of the Charnley prosthesis declines by about 10% during each of the two following decades. Except for the Charnley and Lubinus IP, no other prosthesis on the market in Norway has given long-term results (> 15 years). 5 other cemented implants have given comparable results at about 10 years of follow-up. Some uncemented stems have shown promising medium-term outcome, but no combination of uncemented cup and stem fulfilled the benchmark criterion of ≥ 90% implant survival at 10 years, which we propose as a minimum requirement for unrestricted clinical use for prostheses used in primary THR. New or undocumented implants should be introduced through a four-step model including preclinical testing, small series evaluated by radiosterometry, randomized clinical trial involving comparison with a well-documented prosthesis, and finally, surveillance of clinical use through registers.


  • Open Access

    Mechanical Stability of Custom and Anatomical Femoral Stems: An Experimental Study in Human Femora

    by A. Aamodt, J. Lund-Larsen, J. Eine, E. Andersen, P. Benum, O. Schnell Husby

    In this study we have compared the mechanical stability of custom (n=8) and anatomical (n=8) uncemented femoral components, following insertion into human cadaveric femurs, during simulated single leg stance and stair climbing. In the custom group two specimens were excluded from the study due to detachment of the greater trochanter during cyclical loading. As a consequence of their mechanical behaviour both types of stems could be divided into subgroups of “unstable” and “stable” implants. In the course of one thousand loading cycles three anatomical stems and one custom stem migrated more than 1 mm, which was interpreted as mechanical loosening. This difference in rate of mechanical loosening was not significant. However, the majority of the stems were remarkably stable and showed micromotion of less than 18 μm and migration of less than 35 μm at the proximal implant-bone interface. The corresponding figures for the tip of the stems were 243 μm and 170 μm, respectively. During torsional loading the custom stems showed less rotatory motion than the anatomical stem (p<0.05). There were no significant differences in the magnitude of cyclical micromotion or migration for the two types of femoral stems.


  • In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur

    by A. Aamodt, J. Lund‐Larsen, J. Eine, E. Andersen, P. Benum, O. Schnell Husby

    Two conflicting theories exist concerning the stress pattern for the proximal lateral aspect of the human femur. According to the classic theory of Pauwels, a bending moment on the femur leads to compression medially and to tension laterally. The alternative theory is that muscle forces contribute to a moment‐free loading of the femur, with both the medial and lateral cortices subjected to compression. To examine these theories, we measured the strain at the external surface of the proximal lateral aspect of the femur of two female patients undergoing surgery for “snapping hip syndrome.” During the surgical procedure, a strain‐gauge rosette was bonded to the lateral aspect of the femur and the cortical strains were monitored while the patient performed a series of activities. In both patients, principle tensile strain increased significantly during one‐legged stance, walking, and stair climbing as compared with that during two‐legged stance. During each loading situation, the principal tensile strain was aligned within 22° to the longitudinal femoral axis. Dynamic strain measurements consistently revealed tensile axial strain at the lateral aspect of the femur during each activity. The present studv supports the classic bending theory of Pauwels and demonstrates that the proximal lateral aspect of the femur is subjected to tension during the stance phase of gait.


  • Femoral anteversion measured by ultrasound and CT: a comparative study

    by A. Aamodt, T. Terjesen, J. Eine, K. A. Kvistad

    Both computed tomography (CT) and ultrasonography have been used successfully to estimate the femoral anteversion (AV) angle. In this study, AV angles in 20 human adult femurs were determined by ultrasonography and CT and the measurements compared. On CT the real AV angle was measured as the angle between the head-neck centreline and the posterior condylar plane. In addition, the angle between the anterior head-trochanter (HT) tangent and the posterior condylar plane was determined. The latter angle was also measured by ultrasonography using the tilted transducer technique. The mean interobserver variation in the ultrasound measurements was 1.9°. We found ultrasonography to correlate very well with CT, both when comparing with the HT angle (r=0.95) and with the AV angle (r=0.93). The HT angle was on average 4° greater than the AV angle. In this study the accuracy of ultrasonography was ±5° and the method is recommended for screening in patients with rotational disorders of the femur.