- Vol. 51 (1) , 120-123
Introduction to the MAUDE Database
The Manufacturer and User Facility Device Experience (MAUDE) database represents a reporting system mandated by the Food and Drug Administration for postmarket surveillance. MAUDE has been made into a searchable online database that includes all reported events in which medical devices may have malfunctioned or caused a death or serious injury. For the clinician considering the use of a new medical device, searching the MAUDE database is useful to search for complications not yet reported in the medical literature.
- 1 March 2008
- Published by Wolters Kluwer Health in Clinical Obstetrics and Gynecology
- Vol. 51 (1) , 120-123
Introduction to the MAUDE Database
The Manufacturer and User Facility Device Experience (MAUDE) database represents a reporting system mandated by the Food and Drug Administration for postmarket surveillance. MAUDE has been made into a searchable online database that includes all reported events in which medical devices may have malfunctioned or caused a death or serious injury. For the clinician considering the use of a new medical device, searching the MAUDE database is useful to search for complications not yet reported in the medical literature.
- 1 May 2004
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 103 (5, Part 1) , 995
Complications Associated With Global Endometrial Ablation: The Utility of the MAUDE Database
- 1 May 2004
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 103 (5, Part 1) , 995
Complications Associated With Global Endometrial Ablation: The Utility of the MAUDE Database
- 1 December 2003
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 102 (6) , 1278-1282
Complications associated with global endometrial ablation: the utility of the MAUDE database
To investigate the number and type of complications associated with global endometrial ablation using public-access governmental databanks. MEDLINE (PubMed) and the US Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) databases were searched for entries for the four US Food and Drug Administration-approved global endometrial ablation devices. Traditional MEDLINE and bibliography searches yielded reports of two cases of hemorrhage, one case of pelvic inflammatory disease, 20 cases of endometritis, two cases of first-degree skin burns, nine cases of hematometra, and 16 cases of vaginitis and/or cystitis. A search of the US Food and Drug Administration MAUDE database yielded reports of 85 complications in 62 patients. These included major complications: eight cases of thermal bowel injury, 30 cases of uterine perforation, 12 cases in which emergent laparotomy was required, and three intensive care unit admissions. One patient developed necrotizing fasciitis and eventually underwent vulvectomy, ureterocutaneous ostomy, and bilateral below-the-knee amputations. One of the patients with thermal injury to the bowel died. Use of the US Food and Drug Administration MAUDE database is helpful in identifying serious complications associated with global endometrial ablation not yet reported in the medical literature.
- 1 December 2003
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 102 (6) , 1278-1282
Complications associated with global endometrial ablation: the utility of the MAUDE database
To investigate the number and type of complications associated with global endometrial ablation using public-access governmental databanks. MEDLINE (PubMed) and the US Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) databases were searched for entries for the four US Food and Drug Administration-approved global endometrial ablation devices. Traditional MEDLINE and bibliography searches yielded reports of two cases of hemorrhage, one case of pelvic inflammatory disease, 20 cases of endometritis, two cases of first-degree skin burns, nine cases of hematometra, and 16 cases of vaginitis and/or cystitis. A search of the US Food and Drug Administration MAUDE database yielded reports of 85 complications in 62 patients. These included major complications: eight cases of thermal bowel injury, 30 cases of uterine perforation, 12 cases in which emergent laparotomy was required, and three intensive care unit admissions. One patient developed necrotizing fasciitis and eventually underwent vulvectomy, ureterocutaneous ostomy, and bilateral below-the-knee amputations. One of the patients with thermal injury to the bowel died. Use of the US Food and Drug Administration MAUDE database is helpful in identifying serious complications associated with global endometrial ablation not yet reported in the medical literature.