HYHuiguang Yang

Huiguang Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huiguang Yang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 April 2012
      • Vol. 26  (4) , 411-5

    [Percutaneous kyphoplasty in hyperextension position for treatment of middle and late period Kümmell disease].

    by Yunqing Zhang, Huiguang Yang, Yong Liu, Feng Zhou, Xiongwei Deng, Wenxing Luo, Liang Chen

    To evaluate the feasibility and effectiveness of percutaneous kyphoplasty in hyperextension position for treatment of stage II or III Kümmell disease. Between May 2003 and February 2009, 17 patients with Kümmell disease (6 at stage II, 11 at stage III) were treated with percutaneous kyphoplasty in hyperextension position. There were 5 males and 12 females with an average age of 71 years (range, 55-85 years). The involved vertebral bodies were T10 in 1 case, T11 in 3 cases, T12 in 7 cases, L1 in 4 cases, L2 in 1 case, and T12, L1 in 1 case by X-ray, CT, and MRI examinations. The effectiveness was determined by the visual analogue scale (VAS) and the Oswestry Disability Index (ODI). The height and the kyphotic Cobb angle of the involved vertebral body were measured pre- and postoperatively. The operation was successfully completed in all the patients, and the incisions healed by first intention. Pain was alleviated or eliminated within 48 hours after operation; no spinal nerves injury or pulmonary embolism occurred. One patient had cement leakage to the adjacent disc, who did not manifest any clinical symptoms. Thirteen patients were followed up 24 to 56 months (mean, 32 months). The VAS score, ODI, anterior and medial vertebral height, kyphotic Cobb angle of involved vertebral body were improved significantly at 1 week after operation and at last follow-up (P < 0.05), there was no significant difference between at 1 week after operation and at last follow-up (P > 0.05). Adjacent vertebral fracture occurred in 1 patient at 6 months after operation and was cured after percutaneous kyphoplasty. Percutaneous kyphoplasty in hyperextension position for treatment of stage II or III Kümmell disease can relieve back pain, improve viability, decrease Cobb angle, and retain the vertebral body height and spinal alignment. The general condition of the patient is needed to be evaluated and the operation indication should be controlled strictly.

  • A Prospective Clinical Study of Proximal Humerus Fractures Treated With a Locking Proximal Humerus Plate

    by Huiguang Yang, Zhongze Li, Feng Zhou, Daoyuan Wang, Baoliang Zhong

    The purpose of this prospective study was to evaluate the safety, efficacy, and functional outcome of the locked proximal humerus plate (LPHP) to treat proximal humerus fractures. Prospective clinical trial. University orthopedic center. Over a 25-month period, 64 consecutive patients were treated with a LPHP for an unstable or displaced proximal humerus fracture. Demographic data, trauma mechanisms, surgical approaches, and postoperative complications were collected from medical records. Fracture classification according to the Neer classification, radiographic head-shaft angle, and screw tip-articular surface distance in true anteroposterior and axillary lateral radiographs of the shoulder were measured postoperatively. The functional outcome was evaluated with a Constant-Murley (CM) evaluation. The CM score is a validated shoulder-specific scoring system in which patients report subjective findings. The physician reported the objective measurements of the shoulder. Follow-ups were completed for all of the patients. The overall complication rate was 35.9%, with screw penetration into the glenohumeral joint as the most frequent problem (7.6%). Deep wound infections were observed in 3.1% (n = 2) of the cases and avascular necrosis in 3.1% (n = 2). All complications occurred in 4-part fractures. Subacromial impingement, frozen shoulder, rotator cuff rupture, and wound dehiscence were observed in 3.1% (n = 2), 3.1% (n = 2), 1.6% (n = 1), and 1.6% (n = 1) of the cases, respectively. Multivariate linear regression analysis revealed that the fracture pattern and the presence or absence of medial support were significant predictors of functional outcome (P = 0.026 and P = 0.003, respectively). Patient age (P = 0.581), sex (P = 0.325), and initial tuberosity displacement (varus/extension or valgus/impaction; P = 0.059) were not significantly associated with the CM score. The LPHP seems to be a promising implant for the fixation of proximal humerus fractures. However, there are certain limitations that should be mentioned. The number of cases in our study was small, and no safe conclusions can be extracted regarding the rate of avascular necrosis. Additional studies with larger cohorts and longer follow-ups are necessary to better define the appropriate indications for and expected outcomes of this technology.