CYC. C. Youngson

C. C. Youngson

*This is an algorithmically generated author record based on publicly available information.

C. C. Youngson has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Microleakage of glass-ionomer cement placed in association with non-setting calcium hydroxide

    by S. A. Mahmood, D. J. Wood, E. L. Boyle, F. D. Jarad, C. C. Youngson

    The purpose of this investigation was to determine whether non-setting calcium hydroxide [Ca (OH)2] cement placed in the root canal system of premolar teeth would affect the subsequent microleakage of a glass-ionomer restoration (GIC). Following selection, 62 human premolar teeth extracted for orthodontic reasons were accessed and root canals prepared according to a standardized procedure. The specimens were then allocated randomly into two major groups each of 30 teeth. Two other teeth were used as a positive and a negative control. The control group was restored with glass-ionomer cement following drying of the canal and placement of a cotton wool pledget. The test group had all canals dressed with non-setting Ca(OH)2 and then was subdivided, one set (n = 22) being restored following conditioning of the access cavity margins, the other (n = 8) having the margins cleaned with a hand excavator. Samples were assessed for microleakage using a two-point scoring system (leakage or no leakage) in conjunction with a clearing technique using AgNO3. Using Fisher's exact test, a statistically significant difference was found between the control and test groups (P < 0.05) but there was no significant difference between the excavated and conditioned cavities (P=0.55). It is concluded that contamination of access cavity margins with Ca(OH)2 during medication of a root canal interferes with the bond of GIC, resulting in increased microleakage in vitro.


  • A clinical report of 85 fractured metallic post‐retained crowns

    by K. Fox, D. J. Wood, C. C. Youngson

    Aim  To determine any patient, technique or material factors that were significantly associated with post fracture in metallic post systems.Summary  Eighty‐five fractured metal posts were retrieved over a 5‐year period from a total of 84 patients who attended a dental hospital for treatment. A record was kept of the patient's dentition to identify the tooth with the fractured post, the number of teeth present, the excursive guidance scheme and the likely post design and material. Radiographs of 67 of these teeth were available. The presence or absence of a periapical lesion was noted as was the quality of the root filling. Maxillary lateral incisors, followed by maxillary centrals were associated with most of the fractured posts. The median survival to fracture was 36 months. The number of teeth in the dentition had a mode of 28. The most commonly fractured post design was a serrated and parallel design with an average diameter of 1.2 mm at the site of fracture. Apical lesions were found in 67% of the teeth with radiographs. Only 12% of teeth with a ‘good’ apical filling as opposed to 55% with a ‘poor’ apical filling had apical lesions.Key learning points: Maxillary lateral incisors, followed by maxillary central incisors are at greatest risk of having a fractured metallic post. Having a large number of teeth in the dentition or an adequate length of post was not protective against metallic post fracture. Teeth with fractured post‐retained crowns had a high incidence of apical lesions.