Adrian C. Shortall
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Adrian C. Shortall has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Ayman Ellakwa
School of Dentistry, The University of Sydney, Westmead NSW 2145, Australia
5 shared publications - P. M. Marquis
School of Dentistry, University of Birmingham, Birmingham, UK
5 shared publications E Harrington
Senior Research Technician, The University of Birmingham, The School of Dentistry, St. Chad's Queensway, Birmingham B4 6NN, England
3 shared publicationsP. M. Marquis
School of Dentistry, The University of Birmingham, St Chad's Queensway, Birmingham, UK
3 shared publications- William M. Palin
University of Birmingham, College of Medical and Dental Sciences, Institute of Clinical Sciences, 5 Mill Pool Way, Edgbaston, Birmingham, B5 7EG, UK
2 shared publications X. Hu
School of Dentistry, The University of Birmingham, St Chad's Queensway, Birmingham, UK
2 shared publications
Latest Publications
- Open Access
- 20 March 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (6) , 2803
The Role of Rapid Curing on the Interrelationship Between Temperature Rise, Light Transmission, and Polymerisation Kinetics of Bulk-Fill Composites
The first seconds of light curing are crucial for the development of most properties of dental composites, especially for the 3s high-irradiance curing. This study investigated the influence of rapid high-irradiance curing on temporal development of temperature, transmittance and conversion of bulk-fill composites. Four materials were tested: Filtek One (FO), Tetric PowerFill (PFill), Tetric PowerFlow (PFlow) and SDR flow+ (SDR+) and cured with three curing units (LCU): Valo Cordles, Bluephase PowerCure and Translux Wave in 3s (3 W/cm2), 10s (1 W/cm2) and 20s (1 W/cm2) curing protocols. Light transmittance was measured at 2 and 4 mm, while temperature rise and polymerisation kinetics were evaluated at 4 mm depth during 5 min. Both light transmittance and temperature rise were greatest for SDR+ > PFlow > PFill > FO. The 20s curing protocol resulted in the highest degree of conversion (DC) for all materials and LCUs, but also contributed to the greatest temperature rise. Rapid curing with the 3s protocol caused the lowest temperature rise and the shortest time to reach maximum temperature. The polymerisation and temperature kinetics were strongly dependent on the material. The DC of PFill was statistically similar for 3s, 10s or 20s curing with BPC. Rapid curing is only recommended for materials developed for this purpose.
- 20 March 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (6) , 2803
Open AccessThe Role of Rapid Curing on the Interrelationship Between Temperature Rise, Light Transmission, and Polymerisation Kinetics of Bulk-Fill Composites
The first seconds of light curing are crucial for the development of most properties of dental composites, especially for the 3s high-irradiance curing. This study investigated the influence of rapid high-irradiance curing on temporal development of temperature, transmittance and conversion of bulk-fill composites. Four materials were tested: Filtek One (FO), Tetric PowerFill (PFill), Tetric PowerFlow (PFlow) and SDR flow+ (SDR+) and cured with three curing units (LCU): Valo Cordles, Bluephase PowerCure and Translux Wave in 3s (3 W/cm2), 10s (1 W/cm2) and 20s (1 W/cm2) curing protocols. Light transmittance was measured at 2 and 4 mm, while temperature rise and polymerisation kinetics were evaluated at 4 mm depth during 5 min. Both light transmittance and temperature rise were greatest for SDR+ > PFlow > PFill > FO. The 20s curing protocol resulted in the highest degree of conversion (DC) for all materials and LCUs, but also contributed to the greatest temperature rise. Rapid curing with the 3s protocol caused the lowest temperature rise and the shortest time to reach maximum temperature. The polymerisation and temperature kinetics were strongly dependent on the material. The DC of PFill was statistically similar for 3s, 10s or 20s curing with BPC. Rapid curing is only recommended for materials developed for this purpose.
- 1 May 2013
- Published by Elsevier in Journal of Dentistry
- Vol. 41 (5) , 455-463
Initial fracture resistance and curing temperature rise of ten contemporary resin-based composites with increasing radiant exposure
- 1 May 2013
- Published by Elsevier in Journal of Dentistry
- Vol. 41 (5) , 455-463
Initial fracture resistance and curing temperature rise of ten contemporary resin-based composites with increasing radiant exposure
- Top Cited Papers
- 1 January 2008
- Published by SAGE Publications in Journal of Dental Research
- Vol. 87 (1) , 84-88
Refractive Index Mismatch and Monomer Reactivity Influence Composite Curing Depth
Limited cure depth is a drawback of light-activated composites. We hypothesize that curing light transmission and cure depth are influenced by monomer reactivity and filler/resin refractive index mismatch. Light transmission throughout cure was recorded for composites based on strontium (refractive index 1.51) or barium (refractive index 1.53) glass fillers. Fillers were mixed (70 wt%) with 4 bisphenol-A diglycidyl-ether-dimethacrylate (bis-GMA):triethylene glycol dimethacrylate (TEGDMA) formulations with refractive indices ranging from 1.4703 to 1.5370. Following polymerization, cure depth and pre- and post-cure translucency parameters were determined. Transmission changes and cure depths related to monomer reactivity and filler/resin refractive index mismatch with significant interaction. Composites became more opaque or translucent on curing. Optimizing filler/resin refractive index mismatch provides increased curing depth and assists shade-matching.
- 1 January 2008
- Published by SAGE Publications in Journal of Dental Research
- Vol. 87 (1) , 84-88
Top Cited PapersRefractive Index Mismatch and Monomer Reactivity Influence Composite Curing Depth
Limited cure depth is a drawback of light-activated composites. We hypothesize that curing light transmission and cure depth are influenced by monomer reactivity and filler/resin refractive index mismatch. Light transmission throughout cure was recorded for composites based on strontium (refractive index 1.51) or barium (refractive index 1.53) glass fillers. Fillers were mixed (70 wt%) with 4 bisphenol-A diglycidyl-ether-dimethacrylate (bis-GMA):triethylene glycol dimethacrylate (TEGDMA) formulations with refractive indices ranging from 1.4703 to 1.5370. Following polymerization, cure depth and pre- and post-cure translucency parameters were determined. Transmission changes and cure depths related to monomer reactivity and filler/resin refractive index mismatch with significant interaction. Composites became more opaque or translucent on curing. Optimizing filler/resin refractive index mismatch provides increased curing depth and assists shade-matching.
- 1 December 2006
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 33 (12) , 924-933
Marginal adaptation and micro-porosity of class II restorations of a high copper amalgam and a palladium-free gallium-based alloy
The aim of the current investigation was to compare the marginal adaptation and internal porosity of a gallium (Ga)-based alloy (Galloy) with a high copper amalgam (Permite C DP) when used in moderately sized conventional class II cavities. Ten dentists placed two restorations of each material in standardized class II cavities in typodont teeth set in a phantom head. The proximal surfaces of the restored teeth were subsequently examined using an optical microscope and colour photographs were taken. The teeth were then serially sectioned before being re-examined microscopically and re-photographed. Three dentists rated the photographs of the restorations on two occasions, 2 weeks apart, for marginal adaptation and internal porosity using a six and five point scoring criteria, respectively. Inter- and intra-examiner agreements were assessed with weighted kappa statistics. The Ga-based alloy exhibited inferior marginal adaptation and a significantly higher level of porosity and internal defects compared with the dental amalgam. Marginal defects were mainly concentrated at the gingival third of the proximal boxes for both alloys. The poor marginal adaptation and extensive internal porosity detected for the Ga-based alloy was attributed to the difficulty in the alloy condensation related mainly to the 'stickiness' of the alloy to the condensers and to the rapid change in the plasticity of the alloy during condensation. This could possibly be a factor in the post-operative complications reported with the clinical use of this alloy.
- 1 December 2006
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 33 (12) , 924-933
Marginal adaptation and micro-porosity of class II restorations of a high copper amalgam and a palladium-free gallium-based alloy
The aim of the current investigation was to compare the marginal adaptation and internal porosity of a gallium (Ga)-based alloy (Galloy) with a high copper amalgam (Permite C DP) when used in moderately sized conventional class II cavities. Ten dentists placed two restorations of each material in standardized class II cavities in typodont teeth set in a phantom head. The proximal surfaces of the restored teeth were subsequently examined using an optical microscope and colour photographs were taken. The teeth were then serially sectioned before being re-examined microscopically and re-photographed. Three dentists rated the photographs of the restorations on two occasions, 2 weeks apart, for marginal adaptation and internal porosity using a six and five point scoring criteria, respectively. Inter- and intra-examiner agreements were assessed with weighted kappa statistics. The Ga-based alloy exhibited inferior marginal adaptation and a significantly higher level of porosity and internal defects compared with the dental amalgam. Marginal defects were mainly concentrated at the gingival third of the proximal boxes for both alloys. The poor marginal adaptation and extensive internal porosity detected for the Ga-based alloy was attributed to the difficulty in the alloy condensation related mainly to the 'stickiness' of the alloy to the condensers and to the rapid change in the plasticity of the alloy during condensation. This could possibly be a factor in the post-operative complications reported with the clinical use of this alloy.
- 18 November 2005
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 32 (12) , 906-911
How light source and product shade influence cure depth for a contemporary composite
summary Directly placed light activated resin based composite restorations are becoming increasingly popular for restoring cavities in posterior teeth. Marketing and patient as factors well as operator preference are behind this trend. Achieving adequate depth of cure is critical to the success of these restorations. Recently a number of second generation light emitting diode (LED) light activation units have been marketed and the manufacturer of one of these claims that it is capable of curing in half the time of its predecessor. This study tested that claim using a companion composite from the same manufacturer. The relationship between cure depth, shade changes on curing and opacity were also assessed. Under the limitations of the current investigation the results indicated that the second generation LED unit in question met the manufacturer's claim for halving cure time. Depths of cure approached those of a control halogen unit in half the 40 s radiation time of the latter. For the product tested depth of cure is strongly linked to material opacity.
- 18 November 2005
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 32 (12) , 906-911
How light source and product shade influence cure depth for a contemporary composite
summary Directly placed light activated resin based composite restorations are becoming increasingly popular for restoring cavities in posterior teeth. Marketing and patient as factors well as operator preference are behind this trend. Achieving adequate depth of cure is critical to the success of these restorations. Recently a number of second generation light emitting diode (LED) light activation units have been marketed and the manufacturer of one of these claims that it is capable of curing in half the time of its predecessor. This study tested that claim using a companion composite from the same manufacturer. The relationship between cure depth, shade changes on curing and opacity were also assessed. Under the limitations of the current investigation the results indicated that the second generation LED unit in question met the manufacturer's claim for halving cure time. Depths of cure approached those of a control halogen unit in half the 40 s radiation time of the latter. For the product tested depth of cure is strongly linked to material opacity.
- 23 July 2005
- Published by Springer Nature in British Dental Journal
- Vol. 199 (2) , 73-79
Can a single composite resin serve all purposes?
The role of the BDJ is to inform its readers of ideas, opinions, developments and key issues in dentistry - clinical, practical and scientific - stimulating interest, debate and discussion amongst dentists of all disciplines.
- 23 July 2005
- Published by Springer Nature in British Dental Journal
- Vol. 199 (2) , 73-79
Can a single composite resin serve all purposes?
The role of the BDJ is to inform its readers of ideas, opinions, developments and key issues in dentistry - clinical, practical and scientific - stimulating interest, debate and discussion amongst dentists of all disciplines.
- 5 June 2003
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 30 (7) , 679-682
Influence of fibre position on the flexural properties and strain energy of a fibre‐reinforced composite
Summary The introduction of laboratory‐processed composite systems and fibre reinforcement techniques have increased the possibilities for the prosthetic replacement of missing tooth tissues. Laboratory fabrication variables may significantly influence the properties of the final prosthesis. During the construction of a fibre‐reinforced bridge it is necessary to place the fibre at some distance from the fitting surface of the restoration in the pontic region. No guidelines are available for optimal fibre placement in this respect. The purpose of this study was to assess the influence of placing ultra high molecular weight polyethylene (UHMWPE) fibre at five different distances from the tensile side of test samples on flexural properties and the strain energy stored within the dental composite. The results of this investigation showed that whilst moving the fibre reinforcement away from the tensile side by up to 1·5 mm led to a significant reduction in flexural strength, there was no significant decline in the increase in strain energy stored within the tested composite until this distance was exceeded.
- 5 June 2003
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 30 (7) , 679-682
Influence of fibre position on the flexural properties and strain energy of a fibre‐reinforced composite
Summary The introduction of laboratory‐processed composite systems and fibre reinforcement techniques have increased the possibilities for the prosthetic replacement of missing tooth tissues. Laboratory fabrication variables may significantly influence the properties of the final prosthesis. During the construction of a fibre‐reinforced bridge it is necessary to place the fibre at some distance from the fitting surface of the restoration in the pontic region. No guidelines are available for optimal fibre placement in this respect. The purpose of this study was to assess the influence of placing ultra high molecular weight polyethylene (UHMWPE) fibre at five different distances from the tensile side of test samples on flexural properties and the strain energy stored within the dental composite. The results of this investigation showed that whilst moving the fibre reinforcement away from the tensile side by up to 1·5 mm led to a significant reduction in flexural strength, there was no significant decline in the increase in strain energy stored within the tested composite until this distance was exceeded.
- 5 June 2003
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 30 (7) , 729-737
Influence of filler loading on the two‐body wear of a dental composite
summary The purpose of the study was to explore the fundamental wear behaviour of a dental composite with different filler loadings under two‐body wear conditions. The parent resin and filler components were mixed according to different weight ratios to produce experimental composites with filler loadings ranging from 20 to 87·5% by weight. A two‐body wear test was conducted on the experimental composites using a wear‐testing machine. The machine was designed to simulate the impact of the direct cyclic masticatory loading that occurs in the occlusal contact area in vivo. The results showed that there was little increase in the rate of wear with filler loadings below 60 wt%, but a sharp increase between 80 and 87·5 wt% in filler loading. Wide striations and bulk loss of material were apparent on the wear surfaces at higher filler loadings. Coefficients of friction increased with filler loading and followed the increase in rate of wear loss closely. It was concluded that, under two‐body wear conditions, addition of high levels of filler particles into the resin matrix could reduce the wear resistance of dental composites. This finding may help when designing future dental composites for use in particular clinical settings.
- 5 June 2003
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 30 (7) , 729-737
Influence of filler loading on the two‐body wear of a dental composite
summary The purpose of the study was to explore the fundamental wear behaviour of a dental composite with different filler loadings under two‐body wear conditions. The parent resin and filler components were mixed according to different weight ratios to produce experimental composites with filler loadings ranging from 20 to 87·5% by weight. A two‐body wear test was conducted on the experimental composites using a wear‐testing machine. The machine was designed to simulate the impact of the direct cyclic masticatory loading that occurs in the occlusal contact area in vivo. The results showed that there was little increase in the rate of wear with filler loadings below 60 wt%, but a sharp increase between 80 and 87·5 wt% in filler loading. Wide striations and bulk loss of material were apparent on the wear surfaces at higher filler loadings. Coefficients of friction increased with filler loading and followed the increase in rate of wear loss closely. It was concluded that, under two‐body wear conditions, addition of high levels of filler particles into the resin matrix could reduce the wear resistance of dental composites. This finding may help when designing future dental composites for use in particular clinical settings.
- 14 September 2002
- Published by Springer Nature in British Dental Journal
- Vol. 193 (5) , 276-280
A pilot investigation of operator variability during intra-oral light curing
Objective To test the hypothesis that operator experience influences the efficacy of light curing in a typical posterior intra-oral location. To investigate whether short cure cycles affect performance. Design A cross-sectional single-centre study designed to assess the efficacy of experienced and inexperienced operators when undertaking simulated intra-oral curing. Setting An in vitro laboratory based investigation conducted in a dental school during 2001. Materials and methods A computer-based technique was used to monitor light intensity in a clinical simulation. Dentists and student operators were tested for their ability to cure a posterior restoration effectively. Relative light intensity was assessed against time for each operator and test run. Results Experienced (qualified) operators produced more effective and consistent cure results than less experienced undergraduate students. Operator performance was not affected by variations in irradiation time. Conclusions This cross-sectional pilot investigation demonstrates that operator experience is a factor in successful clinical photo-curing of posterior restorations. Stable and accurate light guide positioning are required throughout the entire irradiation cycle to optimise intra-oral cure of light-activated restorations. Further investigations are planned to assess the potential of this novel method of assessment for use as a routine teaching aid in clinical practice.
- 14 September 2002
- Published by Springer Nature in British Dental Journal
- Vol. 193 (5) , 276-280
A pilot investigation of operator variability during intra-oral light curing
Objective To test the hypothesis that operator experience influences the efficacy of light curing in a typical posterior intra-oral location. To investigate whether short cure cycles affect performance. Design A cross-sectional single-centre study designed to assess the efficacy of experienced and inexperienced operators when undertaking simulated intra-oral curing. Setting An in vitro laboratory based investigation conducted in a dental school during 2001. Materials and methods A computer-based technique was used to monitor light intensity in a clinical simulation. Dentists and student operators were tested for their ability to cure a posterior restoration effectively. Relative light intensity was assessed against time for each operator and test run. Results Experienced (qualified) operators produced more effective and consistent cure results than less experienced undergraduate students. Operator performance was not affected by variations in irradiation time. Conclusions This cross-sectional pilot investigation demonstrates that operator experience is a factor in successful clinical photo-curing of posterior restorations. Stable and accurate light guide positioning are required throughout the entire irradiation cycle to optimise intra-oral cure of light-activated restorations. Further investigations are planned to assess the potential of this novel method of assessment for use as a routine teaching aid in clinical practice.
- 1 August 2002
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 29 (8) , 756-764
Wear of three dental composites under different testing conditions
Summary Although a great effort has been made to date with research on in vitro wear simulation testing, it is difficult to identify the relationship between the results of in vitro testing and in vivo observations. An intensive study into wear mechanisms is necessary for wear testing simulation. The objective of this research was to study the wear behaviour of three selected dental composites under different wear conditions to provide a more rational explanation for their wear mechanisms. Two typical wear conditions, two‐ and three‐body wear, were conducted on the composites. The results showed that the wear losses had different rankings between two wear conditions. It is therefore unreliable to predict the clinical performance merely by wear loss ranking from in vitro wear testing. Further analysis on the wear surfaces indicated that three dental composites experienced different wear mechanisms under different wear conditions. It is concluded that in vitro analysis of wear mechanisms may lead to a better understanding of in vivo failure patterns. Similar wear mechanisms should be the premise for any correlation between the results of in vitro and in vivo studies.
- 1 August 2002
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 29 (8) , 756-764
Wear of three dental composites under different testing conditions
Summary Although a great effort has been made to date with research on in vitro wear simulation testing, it is difficult to identify the relationship between the results of in vitro testing and in vivo observations. An intensive study into wear mechanisms is necessary for wear testing simulation. The objective of this research was to study the wear behaviour of three selected dental composites under different wear conditions to provide a more rational explanation for their wear mechanisms. Two typical wear conditions, two‐ and three‐body wear, were conducted on the composites. The results showed that the wear losses had different rankings between two wear conditions. It is therefore unreliable to predict the clinical performance merely by wear loss ranking from in vitro wear testing. Further analysis on the wear surfaces indicated that three dental composites experienced different wear mechanisms under different wear conditions. It is concluded that in vitro analysis of wear mechanisms may lead to a better understanding of in vivo failure patterns. Similar wear mechanisms should be the premise for any correlation between the results of in vitro and in vivo studies.