Liliana Werner
Research Subjects
Research Interests
Liliana Werner has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Manfred Tetz
5 shared publicationsMatthias Müller
From the Berlin Eye Research Institute (Werner, Müller, Tetz), Berlin, Germany, the John A. Moran Eye Center (Werner), University of Utah, Salt Lake City, Utah, USA, the Fraunhofer-Institute for Applied Polymer Research (Storsberg, Mauger), Potsdam-Golm, Germany, and the Augenklinik Ahaus (Brasse, Gerl), Ahaus, Germany
2 shared publications- Hasan Alsetri
Weill Cornell Medicine-Qatar, Education City, Qatar Foundation, Doha, Qatar
1 shared publication Ines Feldmann
1 shared publication- Irina S. Barequet
Goldschleger Eye Institute, Sheba Medical Center, Tel Hashomer, Ramat Gan, Israel; Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel
1 shared publication Joachim Storsberg
From the Berlin Eye Research Institute (Werner, Müller, Tetz), Berlin, Germany, the John A. Moran Eye Center (Werner), University of Utah, Salt Lake City, Utah, USA, the Fraunhofer-Institute for Applied Polymer Research (Storsberg, Mauger), Potsdam-Golm, Germany, and the Augenklinik Ahaus (Brasse, Gerl), Ahaus, Germany
1 shared publication
Latest Publications
- 26 October 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Clinical Features, Phenotypic Spectrum, and Associated Factors in Histopathologically Confirmed Dead Bag Syndrome
Purpose: To characterize the demographic, ocular, systemic, and histopathologic features of patients undergoing surgery for late intraocular lens (IOL) instability with clinically suspected dead bag syndrome (DBS). Setting: Private ophthalmology practice and tertiary ophthalmic pathology laboratory. Design: Single-center consecutive case series with prospective tissue collection and retrospective chart review. Methods: Capsular bag remnants were explanted during secondary IOL surgery and submitted for histopathologic examination. Demographic, ocular, and systemic characteristics were obtained from the medical record. Lens epithelial cell (LEC) status was graded as 0 = absent; 1 = rare residual LECs; 2 = focal identifiable LEC segments. Specimens were assessed for capsular splitting/schisis, cortical material, and anterior capsular fibrous metaplasia. Exploratory clinical comparisons were performed between LEC grade 0 and LEC grade 1-2 subgroups. Results: Thirty-one eyes from 26 patients underwent secondary IOL surgery for late IOL subluxation or dislocation with clinical suspicion of DBS, including 27 with histopathologic evaluation. Mean age at secondary surgery was 70.5 ± 10.5 years and 80.7% patients were male. Median time from cataract surgery to presentation was 13.0 years (IQR 9.0-16.5). Axial myopia was present in 6/31 eyes (19.4%). Atopy was documented in 9/31 (29.0%), prior radiation or chemotherapy exposure in 8/31 (25.8%), autoimmune disease in 10/31 (32.3%), and ACE inhibitor or ARB use in 14/31 (45.2%). Complete LEC absence (grade 0) was present in 8/27 (29.6%), while 19/27 (70.4%) demonstrated residual LECs and/or cortical material (grades 1-2). Spontaneous posterior capsular rupture was documented in 15/31 (48.4%) cases and in 15/27 (55.6%) histopathology-confirmed cases. Atopy was more frequent in LEC grade 0 than among LEC grade 1-2 eyes (37.5% vs 15.8%; P = 0.32), though this did not reach statistical significance. Conclusions: DBS represents a histopathologically definable spectrum of capsular degeneration characterized by LEC depletion and capsular splitting with structural failure leading to late IOL instability. Nearly half of confirmed cases presented without clinically evident spontaneous posterior capsular rupture, suggesting that rupture is not required for DBS diagnosis.
- 26 October 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
Clinical Features, Phenotypic Spectrum, and Associated Factors in Histopathologically Confirmed Dead Bag Syndrome
Purpose: To characterize the demographic, ocular, systemic, and histopathologic features of patients undergoing surgery for late intraocular lens (IOL) instability with clinically suspected dead bag syndrome (DBS). Setting: Private ophthalmology practice and tertiary ophthalmic pathology laboratory. Design: Single-center consecutive case series with prospective tissue collection and retrospective chart review. Methods: Capsular bag remnants were explanted during secondary IOL surgery and submitted for histopathologic examination. Demographic, ocular, and systemic characteristics were obtained from the medical record. Lens epithelial cell (LEC) status was graded as 0 = absent; 1 = rare residual LECs; 2 = focal identifiable LEC segments. Specimens were assessed for capsular splitting/schisis, cortical material, and anterior capsular fibrous metaplasia. Exploratory clinical comparisons were performed between LEC grade 0 and LEC grade 1-2 subgroups. Results: Thirty-one eyes from 26 patients underwent secondary IOL surgery for late IOL subluxation or dislocation with clinical suspicion of DBS, including 27 with histopathologic evaluation. Mean age at secondary surgery was 70.5 ± 10.5 years and 80.7% patients were male. Median time from cataract surgery to presentation was 13.0 years (IQR 9.0-16.5). Axial myopia was present in 6/31 eyes (19.4%). Atopy was documented in 9/31 (29.0%), prior radiation or chemotherapy exposure in 8/31 (25.8%), autoimmune disease in 10/31 (32.3%), and ACE inhibitor or ARB use in 14/31 (45.2%). Complete LEC absence (grade 0) was present in 8/27 (29.6%), while 19/27 (70.4%) demonstrated residual LECs and/or cortical material (grades 1-2). Spontaneous posterior capsular rupture was documented in 15/31 (48.4%) cases and in 15/27 (55.6%) histopathology-confirmed cases. Atopy was more frequent in LEC grade 0 than among LEC grade 1-2 eyes (37.5% vs 15.8%; P = 0.32), though this did not reach statistical significance. Conclusions: DBS represents a histopathologically definable spectrum of capsular degeneration characterized by LEC depletion and capsular splitting with structural failure leading to late IOL instability. Nearly half of confirmed cases presented without clinically evident spontaneous posterior capsular rupture, suggesting that rupture is not required for DBS diagnosis.
- Open Access
- 6 June 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (11) , 3350
Ex Vivo Histological Analysis of Corneas with Manually Implanted Intracorneal Stromal Ring Segments
Backgrond: Intracorneal ring segments (ICRSs) are utilized to correct refractive changes impacting visual acuity, commonly implanted via femtosecond laser but can also inserted manually. Corneal deposits alongside the ICRS channels are seen commonly. Methods: This study explores the histological characteristics of corneal deposits following manual ICRS implantation, comparing them to previously published articles describing femtosecond laser-assisted cases. Results: This is a retrospective analysis of three cases involving manual ICRS implantation, accumulation of whitish deposits and later explanation of the corneas due to penetrating keratoplasty (PKP). Patient demographics, ocular history, and surgical details were collected. Histological analysis employed Hematoxylin and Eosin (H&E) and Masson’s trichrome staining. Whitish deposits along ICRS tracts were observed in all cases, with minimal fibroblastic transformation of keratocytes adjacent to the segments. Comparing these cases of manual to femtosecond laser-assisted ICRS implantation, in most cases, similar deposits were identified, indicating the deposits’ association with the stromal tissue reaction to the ring segment and not to the surgical technique. Conclusions: This study contributes insights into the histopathology of manually implanted ICRS, emphasizing the shared nature of deposits in both insertion methods. The findings highlight the link between deposits and the stromal tissue reaction to the ring segment, irrespective of the insertion technique.
- 6 June 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (11) , 3350
Open AccessEx Vivo Histological Analysis of Corneas with Manually Implanted Intracorneal Stromal Ring Segments
Backgrond: Intracorneal ring segments (ICRSs) are utilized to correct refractive changes impacting visual acuity, commonly implanted via femtosecond laser but can also inserted manually. Corneal deposits alongside the ICRS channels are seen commonly. Methods: This study explores the histological characteristics of corneal deposits following manual ICRS implantation, comparing them to previously published articles describing femtosecond laser-assisted cases. Results: This is a retrospective analysis of three cases involving manual ICRS implantation, accumulation of whitish deposits and later explanation of the corneas due to penetrating keratoplasty (PKP). Patient demographics, ocular history, and surgical details were collected. Histological analysis employed Hematoxylin and Eosin (H&E) and Masson’s trichrome staining. Whitish deposits along ICRS tracts were observed in all cases, with minimal fibroblastic transformation of keratocytes adjacent to the segments. Comparing these cases of manual to femtosecond laser-assisted ICRS implantation, in most cases, similar deposits were identified, indicating the deposits’ association with the stromal tissue reaction to the ring segment and not to the surgical technique. Conclusions: This study contributes insights into the histopathology of manually implanted ICRS, emphasizing the shared nature of deposits in both insertion methods. The findings highlight the link between deposits and the stromal tissue reaction to the ring segment, irrespective of the insertion technique.
- 1 July 2009
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (7) , 1273-1280
Detection of pyrogens adsorbed to intraocular lenses
Ed: MicroSil MS 612 ASP, AcrySof SA60AT, Superflex, Sensar, XACT, and LS-106 IOLs. The challenge organism suspensions were 103 CFU/mL and 104 CFU/mL Escherichia coli, 103 CFU/mL and 104 CFU/mL Pseudomonas putida, and 105 CFU/mL and 106 CFU/mL Staphylococcus epidermidis. Two IOLs of each model were incubated at room temperature for at least 2 days in 0.6 mL of 1 of the suspensions. They were then gamma sterilized. The extract of 1 IOL was tested with the LAL assay; the other IOL was tested with the IPT. RESULTS: The LAL was negative for all incubated IOLs. The IPT was positive for all IOLs incubated in E coli and P putida suspensions, with the MicroSil MS 612 ASP, AcrySof SA60AT, XACT, and LS-106 IOLs showing a severe reaction. The Superflex and Sensar IOLs had a slight to moderate response for lower bacterial concentrations and a moderate to severe response for higher concentrations. For S epidermidis, all IOLs showed a slight IPT response except XACT IOLs, which showed a nonpyrogenic response. CONCLUSIONS: Results indicate that the LAL test may fail to detect pyrogens adsorbed to IOLs and the IPT reliably detects pyrogens with a dose-dependent response. This has relevance in the investigation of toxic anterior segment syndrome outbreaks....
- 1 July 2009
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (7) , 1273-1280
Detection of pyrogens adsorbed to intraocular lenses
Ed: MicroSil MS 612 ASP, AcrySof SA60AT, Superflex, Sensar, XACT, and LS-106 IOLs. The challenge organism suspensions were 103 CFU/mL and 104 CFU/mL Escherichia coli, 103 CFU/mL and 104 CFU/mL Pseudomonas putida, and 105 CFU/mL and 106 CFU/mL Staphylococcus epidermidis. Two IOLs of each model were incubated at room temperature for at least 2 days in 0.6 mL of 1 of the suspensions. They were then gamma sterilized. The extract of 1 IOL was tested with the LAL assay; the other IOL was tested with the IPT. RESULTS: The LAL was negative for all incubated IOLs. The IPT was positive for all IOLs incubated in E coli and P putida suspensions, with the MicroSil MS 612 ASP, AcrySof SA60AT, XACT, and LS-106 IOLs showing a severe reaction. The Superflex and Sensar IOLs had a slight to moderate response for lower bacterial concentrations and a moderate to severe response for higher concentrations. For S epidermidis, all IOLs showed a slight IPT response except XACT IOLs, which showed a nonpyrogenic response. CONCLUSIONS: Results indicate that the LAL test may fail to detect pyrogens adsorbed to IOLs and the IPT reliably detects pyrogens with a dose-dependent response. This has relevance in the investigation of toxic anterior segment syndrome outbreaks....
- 1 March 2009
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (3) , 556-566
Evaluating and defining the sharpness of intraocular lenses: Microedge structure of commercially available square-edged hydrophilic intraocular lenses
To evaluate the microstructure of the edges of currently available hydrophilic acrylic intraocular lenses (IOLs) in terms of their deviation from an "ideal" square as a follow-up of preliminary in vitro studies of experimental poly(methyl methacrylate) IOLs and commercially available foldable hydrophobic IOLs. Berlin Eye Research Institute, Berlin, Germany. Twenty-four designs of hydrophilic acrylic IOLs were used in this study. For each design, a +20.0 diopter (D) IOL and a +0.0 D IOL (or the lowest available plus dioptric power) were evaluated. The IOL edge was imaged under low-vacuum (0.7 torr), high-magnification scanning electron microscopy (SEM) using an environmental microscope and standardized technique. The photographs were imported to a digital computer program, and the area above the posterior-lateral edge, representing the deviation from a perfect square, was measured in square microns. Currently available hydrophilic acrylic IOLs labeled as square edged had an area of deviation from a perfect square ranging from 60.84 to 871.51 microm(2) for the +20.0 D IOLs and from 35.52 to 826.55 microm(2) for the low-diopter IOLs. Although some differences in edge finishing between the IOLs analyzed were observed, edge surfaces of hydrophilic acrylic IOLs appeared overall smooth under environmental SEM. Analysis of the microstructure of the optic edge of currently available square-edged hydrophilic acrylic IOLs showed a large variation of the deviation area from a perfect square.
- 1 March 2009
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (3) , 556-566
Evaluating and defining the sharpness of intraocular lenses: Microedge structure of commercially available square-edged hydrophilic intraocular lenses
To evaluate the microstructure of the edges of currently available hydrophilic acrylic intraocular lenses (IOLs) in terms of their deviation from an "ideal" square as a follow-up of preliminary in vitro studies of experimental poly(methyl methacrylate) IOLs and commercially available foldable hydrophobic IOLs. Berlin Eye Research Institute, Berlin, Germany. Twenty-four designs of hydrophilic acrylic IOLs were used in this study. For each design, a +20.0 diopter (D) IOL and a +0.0 D IOL (or the lowest available plus dioptric power) were evaluated. The IOL edge was imaged under low-vacuum (0.7 torr), high-magnification scanning electron microscopy (SEM) using an environmental microscope and standardized technique. The photographs were imported to a digital computer program, and the area above the posterior-lateral edge, representing the deviation from a perfect square, was measured in square microns. Currently available hydrophilic acrylic IOLs labeled as square edged had an area of deviation from a perfect square ranging from 60.84 to 871.51 microm(2) for the +20.0 D IOLs and from 35.52 to 826.55 microm(2) for the low-diopter IOLs. Although some differences in edge finishing between the IOLs analyzed were observed, edge surfaces of hydrophilic acrylic IOLs appeared overall smooth under environmental SEM. Analysis of the microstructure of the optic edge of currently available square-edged hydrophilic acrylic IOLs showed a large variation of the deviation area from a perfect square.
- 1 January 2009
- Published by Touch Medical Media, Ltd. in European Ophthalmic Review
- Vol. 03 (02)
Edge Profiles of Currently Available Intraocular Lenses and Recent Improvements
We evaluated the microstructure of the edges of currently available foldable intraocular lenses (IOLs). The methodology used assisted an IOL manufacturer (Hoya, Japan) to optimise the edge profile of its lenses. Ten designs of hydrophobic acrylic, six designs of silicone and 24 designs of hydrophilic acrylic IOLs were imaged under scanning electron microscopy (SEM), and the photographs were imported to a digital computer program. The area above the posterior–lateral edge, representing the deviation from a perfect square, was measured in square microns. There was a large variation of the area values measured in currently available foldable IOLs labelled as square-edged lenses. As a group, the edges of hydrophilic acrylic lenses were less square than those of hydrophobic acrylic and silicone lenses. Hydrophobic acrylic AF-1 Hoya lenses had a high area value (329.7μ2). Through manufacturing changes, the edges of the lenses were then optimised to a value down to 39.1μ2, which represents the most square hydrophobic acrylic edge currently available.
- 1 January 2009
- Published by Touch Medical Media, Ltd. in European Ophthalmic Review
- Vol. 03 (02)
Edge Profiles of Currently Available Intraocular Lenses and Recent Improvements
We evaluated the microstructure of the edges of currently available foldable intraocular lenses (IOLs). The methodology used assisted an IOL manufacturer (Hoya, Japan) to optimise the edge profile of its lenses. Ten designs of hydrophobic acrylic, six designs of silicone and 24 designs of hydrophilic acrylic IOLs were imaged under scanning electron microscopy (SEM), and the photographs were imported to a digital computer program. The area above the posterior–lateral edge, representing the deviation from a perfect square, was measured in square microns. There was a large variation of the area values measured in currently available foldable IOLs labelled as square-edged lenses. As a group, the edges of hydrophilic acrylic lenses were less square than those of hydrophobic acrylic and silicone lenses. Hydrophobic acrylic AF-1 Hoya lenses had a high area value (329.7μ2). Through manufacturing changes, the edges of the lenses were then optimised to a value down to 39.1μ2, which represents the most square hydrophobic acrylic edge currently available.
- 1 September 2008
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (9) , 1604-1609
Unusual pattern of glistening formation on a 3-piece hydrophobic acrylic intraocular lens
A 3-piece hydrophobic acrylic intraocular lens (IOL) was explanted from the left eye of a 68-year-old patient 26 days after implantation because of glistenings that impaired fundus visualization. The effect of the glistenings on the patient's visual function was unknown because of retinal issues. The fluid-filled vacuoles within the IOL optic were different from those described in clinical and experimental studies. They were initially observed 4 days after surgery and were very large. The glistening formation was reproduced experimentally by immersing the explanted IOL in balanced salt solution at 37 degrees C and analyzing the IOL at room temperature for up to 2 weeks. An IOL of the same design was used as a control. Although both IOLs were subjected to the same laboratory conditions, gross and light microscopic analyses confirmed that the pattern of the glistening formation differed between them. Analyses of the explanted IOL and the control IOL under differential scanning calorimetry, as well as by attenuated total reflection Fourier transform infrared spectroscopy, revealed slight differences between the IOLs.
- 1 September 2008
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (9) , 1604-1609
Unusual pattern of glistening formation on a 3-piece hydrophobic acrylic intraocular lens
A 3-piece hydrophobic acrylic intraocular lens (IOL) was explanted from the left eye of a 68-year-old patient 26 days after implantation because of glistenings that impaired fundus visualization. The effect of the glistenings on the patient's visual function was unknown because of retinal issues. The fluid-filled vacuoles within the IOL optic were different from those described in clinical and experimental studies. They were initially observed 4 days after surgery and were very large. The glistening formation was reproduced experimentally by immersing the explanted IOL in balanced salt solution at 37 degrees C and analyzing the IOL at room temperature for up to 2 weeks. An IOL of the same design was used as a control. Although both IOLs were subjected to the same laboratory conditions, gross and light microscopic analyses confirmed that the pattern of the glistening formation differed between them. Analyses of the explanted IOL and the control IOL under differential scanning calorimetry, as well as by attenuated total reflection Fourier transform infrared spectroscopy, revealed slight differences between the IOLs.
- 1 February 2008
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (2) , 310-317
Evaluating and defining the sharpness of intraocular lenses
To evaluate the microstructure of the edges of currently available square-edged hydrophobic intraocular lenses (IOLs) in terms of their deviation from an ideal square. Berlin Eye Research Institute, Berlin, Germany. Sixteen designs of hydrophobic acrylic or silicone IOLs were studied. For each design, a +20.0 diopter (D) IOL and a +0.0 D IOL (or the lowest available plus dioptric power) were evaluated. The IOL edge was imaged under high-magnification scanning electron microscopy using a standardized technique. The area above the lateral-posterior edge, representing the deviation from a perfect square, was measured in square microns using reference circles of 40 microm and 60 microm of radius and the AutoCAD LT 2000 system (Autodesk). The IOLs were compared with an experimental square-edged poly(methyl methacrylate) (PMMA) IOL (reference IOL) with an edge design that effectively stopped lens epithelial cell growth in culture in a preliminary study. Two round-edged silicone IOLs were used as controls. The hydrophobic IOLs used, labeled as square-edged IOLs, had an area of deviation from a perfect square ranging from 4.8 to 338.4 microm(2) (40 microm radius reference circle) and from 0.2 to 524.4 microm(2) (60 microm radius circle). The deviation area for the square-edged PMMA IOL was 34.0 microm(2) with a 40 microm radius circle and 37.5 microm(2) with a 60 microm radius circle. The respective values for the +20.0 D control silicone IOL were 729.3 microm(2) and 1525.3 microm(2) and for the +0.0 D control silicone IOL, 727.3 microm(2) and 1512.7 microm(2). Seven silicone IOLs of 5 designs had area values that were close to those of the reference square-edged PMMA IOL. Several differences in edge finishing between the IOLs analyzed were also observed. There was a large variation in the deviation area from a perfect square as well as in the edge finishing, not only between different IOL designs but also between different powers of the same design. Clinically, factors such as the shrink-wrapping of the IOL by the capsule may even out or modify the influence of these variations in terms of preventing posterior capsule opacification.
- 1 February 2008
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (2) , 310-317
Evaluating and defining the sharpness of intraocular lenses
To evaluate the microstructure of the edges of currently available square-edged hydrophobic intraocular lenses (IOLs) in terms of their deviation from an ideal square. Berlin Eye Research Institute, Berlin, Germany. Sixteen designs of hydrophobic acrylic or silicone IOLs were studied. For each design, a +20.0 diopter (D) IOL and a +0.0 D IOL (or the lowest available plus dioptric power) were evaluated. The IOL edge was imaged under high-magnification scanning electron microscopy using a standardized technique. The area above the lateral-posterior edge, representing the deviation from a perfect square, was measured in square microns using reference circles of 40 microm and 60 microm of radius and the AutoCAD LT 2000 system (Autodesk). The IOLs were compared with an experimental square-edged poly(methyl methacrylate) (PMMA) IOL (reference IOL) with an edge design that effectively stopped lens epithelial cell growth in culture in a preliminary study. Two round-edged silicone IOLs were used as controls. The hydrophobic IOLs used, labeled as square-edged IOLs, had an area of deviation from a perfect square ranging from 4.8 to 338.4 microm(2) (40 microm radius reference circle) and from 0.2 to 524.4 microm(2) (60 microm radius circle). The deviation area for the square-edged PMMA IOL was 34.0 microm(2) with a 40 microm radius circle and 37.5 microm(2) with a 60 microm radius circle. The respective values for the +20.0 D control silicone IOL were 729.3 microm(2) and 1525.3 microm(2) and for the +0.0 D control silicone IOL, 727.3 microm(2) and 1512.7 microm(2). Seven silicone IOLs of 5 designs had area values that were close to those of the reference square-edged PMMA IOL. Several differences in edge finishing between the IOLs analyzed were also observed. There was a large variation in the deviation area from a perfect square as well as in the edge finishing, not only between different IOL designs but also between different powers of the same design. Clinically, factors such as the shrink-wrapping of the IOL by the capsule may even out or modify the influence of these variations in terms of preventing posterior capsule opacification.