Naoyuki Nomura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Naoyuki Nomura has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Takao Hanawa
Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU), 2-3-10 Kanda-Surugadai, Chiyoda, Tokyo 101-0062, Japan
4 shared publications - Ahmed Jamleh
Department of Restorative Dentistry, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates
1 shared publication - Akihiko Chiba
Institute for Materials Research, Tohoku University
1 shared publication - Alireza Sadr
Department of Restorative Dentistry, University of Washington, Seattle, WA 98195, USA
1 shared publication - Arata Ebihara
Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
1 shared publication Hideaki Suda
Global Center of Excellence (GCOE); International Research Center for Molecular Science in Tooth and Bone Diseases; Tokyo Medical and Dental University; Tokyo Japan
1 shared publication
Latest Publications
- 1 January 2016
- Published by Japan Institute of Metals in MATERIALS TRANSACTIONS
- Vol. 57 (12) , 2060-2064
Effect of Heat Treatment and the Fabrication Process on Mechanical Properties of Zr-14Nb Alloy
- 1 January 2016
- Published by Japan Institute of Metals in MATERIALS TRANSACTIONS
- Vol. 57 (12) , 2060-2064
Effect of Heat Treatment and the Fabrication Process on Mechanical Properties of Zr-14Nb Alloy
- 13 February 2010
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 13 (1) , 10-12
Artificial organs: recent progress in metals and ceramics
The superior properties and novel functions of biomaterials, including metals and ceramics commonly used as implants and medical devices, have been the focus of a number of recent papers. New functions have been explored in metastable beta-Ti alloys, Ni-free Co-Cr-Mo alloys, Mg alloys, and other materials. In addition, porous metals and ceramics with sophisticated structures have been studied as scaffolds for regenerative medicine. In this review, recent advances in bioceramics, metallic biomaterials, and their composites are discussed in terms of their material properties and morphology.
- 13 February 2010
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 13 (1) , 10-12
Artificial organs: recent progress in metals and ceramics
The superior properties and novel functions of biomaterials, including metals and ceramics commonly used as implants and medical devices, have been the focus of a number of recent papers. New functions have been explored in metastable beta-Ti alloys, Ni-free Co-Cr-Mo alloys, Mg alloys, and other materials. In addition, porous metals and ceramics with sophisticated structures have been studied as scaffolds for regenerative medicine. In this review, recent advances in bioceramics, metallic biomaterials, and their composites are discussed in terms of their material properties and morphology.
- Open Access
- 1 January 2010
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 29 (6) , 706-712
Evaluation of the static frictional coefficients of Co-Cr and gold alloys for cone crown telescope denture retainer applications
The static frictional coefficients (SFC) of a Co-Cr and a gold alloys were evaluated for the application of a cone crown telescope system in removable prosthesis. The SFCs of the Co-Cr alloy were lower than those of the gold alloy. The SFC of the gold alloy decreased by annealing at 85°C in air and was restored by re-polishing, although that of the Co-Cr alloy was stable irrespective of the annealing. The XPS analysis revealed the formation of a surface oxide layer on the gold alloy after annealing. The decrease in the SFC of the gold alloy may have been caused by the formation of an oxide layer on the surface due to annealing. The relationships among such factors as the retentive force, SFC and cone crown angle indicate that the angle of the Co-Cr alloy should be lower than that of the gold alloy based on the Körber’s model.
- 1 January 2010
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 29 (6) , 706-712
Open AccessEvaluation of the static frictional coefficients of Co-Cr and gold alloys for cone crown telescope denture retainer applications
The static frictional coefficients (SFC) of a Co-Cr and a gold alloys were evaluated for the application of a cone crown telescope system in removable prosthesis. The SFCs of the Co-Cr alloy were lower than those of the gold alloy. The SFC of the gold alloy decreased by annealing at 85°C in air and was restored by re-polishing, although that of the Co-Cr alloy was stable irrespective of the annealing. The XPS analysis revealed the formation of a surface oxide layer on the gold alloy after annealing. The decrease in the SFC of the gold alloy may have been caused by the formation of an oxide layer on the surface due to annealing. The relationships among such factors as the retentive force, SFC and cone crown angle indicate that the angle of the Co-Cr alloy should be lower than that of the gold alloy based on the Körber’s model.
- Open Access
- 1 January 2010
- Published by Japan Society of Powder and Powder Metallurgy in Journal of the Japan Society of Powder and Powder Metallurgy
- Vol. 57 (2) , 118-125
Mechanical Properties of Zr Added CoCrMo Alloy Sintered Compact Produced by MIM Proces
- 1 January 2010
- Published by Japan Society of Powder and Powder Metallurgy in Journal of the Japan Society of Powder and Powder Metallurgy
- Vol. 57 (2) , 118-125
Open AccessMechanical Properties of Zr Added CoCrMo Alloy Sintered Compact Produced by MIM Proces