Carlo Aratari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carlo Aratari has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Alexander Manché
Department of Cardiothoracic Surgery, Mater Dei Hospital, Msida, Malta
3 shared publications- Alessandro D'Alfonso
Department of Cardiac Surgery, Ospedali Riuniti di Ancona, Ancona, Italy
2 shared publications Filippo Capestro
Division of Cardiac Surgery, Ospedali Riuniti, Ancona, Italy
2 shared publicationsFrancesco Massi
Division of Cardiac Surgery, Ospedali Riuniti, Ancona, Italy
2 shared publications- Lucia Torracca
Cardiac Surgery Division, Lancisi Cardiological Hospital, Ancona, Italy
2 shared publications Diego Magnano
Division of Cardiovascular Surgery, Maria Cecilia Hospital, Cotignola, Ravenna, Italy
1 shared publication
Latest Publications
- 31 October 2014
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 63 (04) , 292-297
Saphenous Vein Graft Wrapping by Nitinol Mesh: A Word of Caution
Background Saphenous vein conduits are still used in a large proportion of coronary artery bypass graft (CABG) operations. A recently commercialized nitinol mesh seems to improve venous graft patency. The aim of this study was to control nitinol mesh vein graft patency in a series of isolated CABG patients by computed tomographic (CT) scan. Methods In 25 patients (mean age: 61.0 ± 9.65 years), operated for isolated CABG, the eSVS nitinol mesh (Kips Bay Medical Inc., Minneapolis, Minnesota, United States) was used to wrap one vein graft in each patient. Nitinol mesh vein graft was used to revascularize the right coronary (4 patients; 16%), the posterior descending (18 patients; 72%), and the obtuse marginal (3 patients; 12%) arteries. CT scans were performed at 1, 6, and 12 months postoperatively. Results The procedure was uneventful in all patients. CT controls showed an overall patency rate of 86.9, 42.7, and 34.1% at 1, 6, and 12 months, respectively. The 4 mm mesh had a significantly higher patency rate at 12 months (83.33%) than the 3.5 mm one which showed quite unsatisfactory results (20%) (p = 0.02). Patients with graft occlusion underwent stress testing which was mildly positive in two cases. One of them underwent a percutaneous revascularization. Conclusion Despite promising early results, use of nitinol mesh for saphenous veins was disappointing in our experience. Further refinements are probably needed.
- 31 October 2014
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 63 (04) , 292-297
Saphenous Vein Graft Wrapping by Nitinol Mesh: A Word of Caution
Background Saphenous vein conduits are still used in a large proportion of coronary artery bypass graft (CABG) operations. A recently commercialized nitinol mesh seems to improve venous graft patency. The aim of this study was to control nitinol mesh vein graft patency in a series of isolated CABG patients by computed tomographic (CT) scan. Methods In 25 patients (mean age: 61.0 ± 9.65 years), operated for isolated CABG, the eSVS nitinol mesh (Kips Bay Medical Inc., Minneapolis, Minnesota, United States) was used to wrap one vein graft in each patient. Nitinol mesh vein graft was used to revascularize the right coronary (4 patients; 16%), the posterior descending (18 patients; 72%), and the obtuse marginal (3 patients; 12%) arteries. CT scans were performed at 1, 6, and 12 months postoperatively. Results The procedure was uneventful in all patients. CT controls showed an overall patency rate of 86.9, 42.7, and 34.1% at 1, 6, and 12 months, respectively. The 4 mm mesh had a significantly higher patency rate at 12 months (83.33%) than the 3.5 mm one which showed quite unsatisfactory results (20%) (p = 0.02). Patients with graft occlusion underwent stress testing which was mildly positive in two cases. One of them underwent a percutaneous revascularization. Conclusion Despite promising early results, use of nitinol mesh for saphenous veins was disappointing in our experience. Further refinements are probably needed.
- 24 June 2013
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 21 (3) , 319-325
Sternal wrapping: developments and results
Background: Postoperative sternal wound complications are infrequent events that negatively affect recovery and may have serious consequences. Sternal wrapping, a technique of sternal care, has hemostatic properties without bone wax, and offers mechanical and microbiologic protection. Methods: From February 1998 to December 2011, 258 patients in 2 Italian institutions underwent various cardiac surgery procedures with sternal wrapping in place, and were followed up for no less then 6 months. Results: Two (0.8%) extremely compromised patients with ischemic sternal osteonecrosis and deep sternal wound infection required a sternal stabilizing procedure. Four (2%) other patients developed sternal wound complications that were treated entirely medically; 3 of them were very trivial, and 1 was an atypical mediastinitis without sternal involvement. Overall, 46.1% of patients (45.3% of isolated coronary artery bypass, 49.3% of isolated on-pump coronary artery bypass, and 18.2% of off-pump coronary artery bypass patients) were transfused. None of the complications was related to sternal wrapping, bleeding from the sternal edge, or sternal wound problems. Conclusions: Sternal wrapping showed a very low incidence and severity of sternal wound complications, with good prevention of sternal osteomyelitis. Hemostatic properties were satisfactory, with transfusion rates within an acceptable range.
- 24 June 2013
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 21 (3) , 319-325
Sternal wrapping: developments and results
Background: Postoperative sternal wound complications are infrequent events that negatively affect recovery and may have serious consequences. Sternal wrapping, a technique of sternal care, has hemostatic properties without bone wax, and offers mechanical and microbiologic protection. Methods: From February 1998 to December 2011, 258 patients in 2 Italian institutions underwent various cardiac surgery procedures with sternal wrapping in place, and were followed up for no less then 6 months. Results: Two (0.8%) extremely compromised patients with ischemic sternal osteonecrosis and deep sternal wound infection required a sternal stabilizing procedure. Four (2%) other patients developed sternal wound complications that were treated entirely medically; 3 of them were very trivial, and 1 was an atypical mediastinitis without sternal involvement. Overall, 46.1% of patients (45.3% of isolated coronary artery bypass, 49.3% of isolated on-pump coronary artery bypass, and 18.2% of off-pump coronary artery bypass patients) were transfused. None of the complications was related to sternal wrapping, bleeding from the sternal edge, or sternal wound problems. Conclusions: Sternal wrapping showed a very low incidence and severity of sternal wound complications, with good prevention of sternal osteomyelitis. Hemostatic properties were satisfactory, with transfusion rates within an acceptable range.
- 19 August 2011
- Published by Springer Nature in Indian Journal of Thoracic and Cardiovascular Surgery
- Vol. 27 (3) , 150
Sternal wound infections: why not try now sternal wrapping?
- 19 August 2011
- Published by Springer Nature in Indian Journal of Thoracic and Cardiovascular Surgery
- Vol. 27 (3) , 150
Sternal wound infections: why not try now sternal wrapping?
- Open Access
- 25 January 2011
- Published by Taylor & Francis in Mechanical Circulatory Support
- Vol. 2 (1) , 11826576
Management of transapical left venting during adult peripheral extracorporeal membrane oxygenation
Extracorporeal membrane oxygenation (ECMO) represents a temporary cardiac assist device. One important drawback of ECMO is related to the fact that inflow comes from the right heart and left ventricle unloading may be incomplete. Left venting is a possible solution that may be performed through apical cannulation. We present our technique management through the left ventricular venting apex. Keywords: left ventricle venting; ECMO (Published: 28 March 2011) Citation: Mechanical Circulatory Support 2011, 2: 5981 - DOI: 10.3402/mcs.v2i0.5981
- 25 January 2011
- Published by Taylor & Francis in Mechanical Circulatory Support
- Vol. 2 (1) , 11826576
Open AccessManagement of transapical left venting during adult peripheral extracorporeal membrane oxygenation
Extracorporeal membrane oxygenation (ECMO) represents a temporary cardiac assist device. One important drawback of ECMO is related to the fact that inflow comes from the right heart and left ventricle unloading may be incomplete. Left venting is a possible solution that may be performed through apical cannulation. We present our technique management through the left ventricular venting apex. Keywords: left ventricle venting; ECMO (Published: 28 March 2011) Citation: Mechanical Circulatory Support 2011, 2: 5981 - DOI: 10.3402/mcs.v2i0.5981
- Open Access
- 1 December 2010
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 11 (6) , 794-795
Cardiopulmonary bypass line sternal wrapping: technical tips
Cardiopulmonary bypass line sternal wrapping (SW) is a new approach to sternal care which avoids bone wax and offers mechanical protection and a shie
- 1 December 2010
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 11 (6) , 794-795
Open AccessCardiopulmonary bypass line sternal wrapping: technical tips
Cardiopulmonary bypass line sternal wrapping (SW) is a new approach to sternal care which avoids bone wax and offers mechanical protection and a shie
- Open Access
- 1 August 2009
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 9 (2) , 147-149
Cardiopulmonary bypass line sternal wrapping for protection and haemostasis
Sternal marrow haemostasis is often obtained with the application of bone wax, with potential side effects pertaining to sternal wound healing. We illustrate an alternative technique which also offers some protection to sternal edges. Two lengths of tubing from the discarded cardiopulmonary bypass (CPB) circuit are cut longitudinally on one side. After sternotomy they are placed across each sternal edge and kept in position by two stitches and the spreader blades. They are removed just before sternal closure.
- 1 August 2009
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 9 (2) , 147-149
Open AccessCardiopulmonary bypass line sternal wrapping for protection and haemostasis
Sternal marrow haemostasis is often obtained with the application of bone wax, with potential side effects pertaining to sternal wound healing. We illustrate an alternative technique which also offers some protection to sternal edges. Two lengths of tubing from the discarded cardiopulmonary bypass (CPB) circuit are cut longitudinally on one side. After sternotomy they are placed across each sternal edge and kept in position by two stitches and the spreader blades. They are removed just before sternal closure.