Simon Nicholas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Simon Nicholas has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Gordon Purdie
2 shared publicationsAli Poostchi
Department of Ophthalmology, Wellington Hospital, Wellington, New Zealand
1 shared publicationAndrew Riley
Ophthalmology Department, Wellington Hospital, Wellington, and Departments of2 Public Health and 3Surgery, Wellington School of Medicine, Otago University, New Zealand
1 shared publicationAnthony P Wells
Ophthalmology Department, Wellington Hospital, Wellington, and Departments of2 Public Health and 3Surgery, Wellington School of Medicine, Otago University, New Zealand
1 shared publicationAnthony Wells
1 shared publicationBridget Neveldson
Ophthalmology Department, Wellington Hospital, Wellington, and Departments of2 Public Health and 3Surgery, Wellington School of Medicine, Otago University, New Zealand
1 shared publication
Latest Publications
- 28 September 2009
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 37 (7) , 687-691
The iCare rebound tonometer: comparisons with Goldmann tonometry, and influence of central corneal thickness
Purpose: To assess agreement between the iCare rebound tonometer and Goldmann tonometry and to assess the influence of central corneal thickness and the value of scleral rebound tonometer readings.Methods: Prospective single‐centre cross‐sectional study comparing iCare rebound tonometer (RT) intraocular pressure (IOP) readings taken from corneal and scleral locations to Goldmann applanation tonometer (GAT) readings in 100 subjects attending ophthalmology clinics.Results: There was a significant difference between RT and GAT, with RT tending to overestimate IOP. The mean difference between RT and GAT measurements was 3.36 mmHg. The mean difference between the log of RT and the log of GAT measurements was 0.2356, a ratio of 1.27 (P < 0.0001). A formula derived from a linear regression analysis suggested that a 10% increase in CCT increased the RT IOP reading by 9.9%. Scleral RT readings showed no relationship to GAT readings.Conclusions: The rebound tonometer cannot replace the Goldmann tonometer in the office setting given the wide limits of agreement between the two devices. Corneal rebound tonometer readings are influenced by CCT whereas scleral rebound tonometer readings are of no value.
- 28 September 2009
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 37 (7) , 687-691
The iCare rebound tonometer: comparisons with Goldmann tonometry, and influence of central corneal thickness
Purpose: To assess agreement between the iCare rebound tonometer and Goldmann tonometry and to assess the influence of central corneal thickness and the value of scleral rebound tonometer readings.Methods: Prospective single‐centre cross‐sectional study comparing iCare rebound tonometer (RT) intraocular pressure (IOP) readings taken from corneal and scleral locations to Goldmann applanation tonometer (GAT) readings in 100 subjects attending ophthalmology clinics.Results: There was a significant difference between RT and GAT, with RT tending to overestimate IOP. The mean difference between RT and GAT measurements was 3.36 mmHg. The mean difference between the log of RT and the log of GAT measurements was 0.2356, a ratio of 1.27 (P < 0.0001). A formula derived from a linear regression analysis suggested that a 10% increase in CCT increased the RT IOP reading by 9.9%. Scleral RT readings showed no relationship to GAT readings.Conclusions: The rebound tonometer cannot replace the Goldmann tonometer in the office setting given the wide limits of agreement between the two devices. Corneal rebound tonometer readings are influenced by CCT whereas scleral rebound tonometer readings are of no value.
- 8 March 2006
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 34 (2) , 124-129
Correlations between optical coherence tomography measurement of macular thickness and visual acuity after cataract extraction
Purpose: To investigate correlations between optical coherence tomography macular thickness measurements and visual acuity after cataract surgery.Methods: Sixty‐two patients underwent routine cataract surgery as part of a randomized clinical trial of oral Cox‐2 inhibitor prophylaxis of cystoid macular oedema. Optical coherence tomography was used to quantify several parameters of macular thickness. Optical coherence tomography measurements were obtained before surgery, day one, week two and week six after surgery. These measurements were then correlated with logMAR best‐corrected visual acuity.Results: Optical coherence tomography macular thickness parameters increased after surgery by up to 20%. A significant correlation was identified between foveal minimum macular thickness and best‐corrected visual acuity at day one and week six after surgery. Other macular parameters failed to show any significant correlation. At day one and week six, the 10 patients with greatest macular thickness had significantly lower visual acuity than the other patients.Conclusion: In this study routine cataract surgery caused an increase in macular thickness. Some significant positive correlations between macular thickness and best‐corrected visual acuity were found, although not for all parameters or time points. There may be a threshold relationship between degree of foveal anatomic change and significant loss of visual acuity.
- 8 March 2006
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 34 (2) , 124-129
Correlations between optical coherence tomography measurement of macular thickness and visual acuity after cataract extraction
Purpose: To investigate correlations between optical coherence tomography macular thickness measurements and visual acuity after cataract surgery.Methods: Sixty‐two patients underwent routine cataract surgery as part of a randomized clinical trial of oral Cox‐2 inhibitor prophylaxis of cystoid macular oedema. Optical coherence tomography was used to quantify several parameters of macular thickness. Optical coherence tomography measurements were obtained before surgery, day one, week two and week six after surgery. These measurements were then correlated with logMAR best‐corrected visual acuity.Results: Optical coherence tomography macular thickness parameters increased after surgery by up to 20%. A significant correlation was identified between foveal minimum macular thickness and best‐corrected visual acuity at day one and week six after surgery. Other macular parameters failed to show any significant correlation. At day one and week six, the 10 patients with greatest macular thickness had significantly lower visual acuity than the other patients.Conclusion: In this study routine cataract surgery caused an increase in macular thickness. Some significant positive correlations between macular thickness and best‐corrected visual acuity were found, although not for all parameters or time points. There may be a threshold relationship between degree of foveal anatomic change and significant loss of visual acuity.