Karsten Friis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Karsten Friis has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
A. Koertzinger
1 shared publicationArne Körtzinger
Leibniz-Institut für Meereswissenschaften, FB Marine Biogeochemistry, Düsternbrooker Weg 20, D-24105 Kiel, Germany
1 shared publication- C. L. Sabine1 shared publication
C. Thomas
1 shared publicationC.D. Winn
1 shared publicationD.W.R. Wallace
1 shared publication
Latest Publications
- Open Access
- 12 May 2004
- Published by Wiley in Limnology and Oceanography: Methods
- Vol. 2 (5) , 126-136
Spectrophotometric pH measurement in the ocean: Requirements, design, and testing of an autonomous charge‐coupled device detector system
A newly designed system for high quality discrete spectrophotometric measurements of pHT using a low‐cost charge‐coupled device (CCD) detector is described. Considerations and requirements for the choice of spectrophotometers with a CCD detector instead of scanning spectrophotometers with photomultiplier detector are elucidated. The presented system is evaluated in the laboratory for system accuracy and short‐term precision and at sea for long‐term precision and at‐sea capability. Derived system characteristics are a (1s) short‐term precision of ±0.0012 pH units and a (1s) long‐term precision at sea of ±0.0032 pH units based on Certified Reference Materials (CRM). Such long‐term precision is equivalent to a deviation of ±1.1 to 2.2 µmol kg−1 in total dissolved inorganic carbon (TCO2) and ±1.4 to 2.1 µmol kg−1 in total alkalinity (TA), depending on temperature and the TCO2/TA ratio. Overdetermination of the CO2 system (TCO2, TA, pHT) from surface‐to‐deep water profiles support the accuracy and precision assessment in comparison to earlier data. With careful design and testing, low‐cost CCD spectrophotometers can be used for high accuracy pH measurements.
- 12 May 2004
- Published by Wiley in Limnology and Oceanography: Methods
- Vol. 2 (5) , 126-136
Open AccessSpectrophotometric pH measurement in the ocean: Requirements, design, and testing of an autonomous charge‐coupled device detector system
A newly designed system for high quality discrete spectrophotometric measurements of pHT using a low‐cost charge‐coupled device (CCD) detector is described. Considerations and requirements for the choice of spectrophotometers with a CCD detector instead of scanning spectrophotometers with photomultiplier detector are elucidated. The presented system is evaluated in the laboratory for system accuracy and short‐term precision and at sea for long‐term precision and at‐sea capability. Derived system characteristics are a (1s) short‐term precision of ±0.0012 pH units and a (1s) long‐term precision at sea of ±0.0032 pH units based on Certified Reference Materials (CRM). Such long‐term precision is equivalent to a deviation of ±1.1 to 2.2 µmol kg−1 in total dissolved inorganic carbon (TCO2) and ±1.4 to 2.1 µmol kg−1 in total alkalinity (TA), depending on temperature and the TCO2/TA ratio. Overdetermination of the CO2 system (TCO2, TA, pHT) from surface‐to‐deep water profiles support the accuracy and precision assessment in comparison to earlier data. With careful design and testing, low‐cost CCD spectrophotometers can be used for high accuracy pH measurements.
- 15 November 1994
- Published by ORNL Environmental Sciences Division
Meteor 06MT19941012 WOCE A02 cruise data from the 1994 cruises, CARINA Data Set
- 15 November 1994
- Published by ORNL Environmental Sciences Division
Meteor 06MT19941012 WOCE A02 cruise data from the 1994 cruises, CARINA Data Set