M. Fawad Khan
M. Fawad Khan has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Adel Maataoui
6 shared publicationsHanns Ackermann
6 shared publicationsThomas J. Vogl
5 shared publicationsChristopher Herzog
Johann Wolfgang Goethe University
4 shared publicationsStefan Wesarg
3 shared publicationsAnton Moritz
Johann Wolfgang Goethe University
2 shared publications
Latest Publications
- 31 August 2010
- Published by Elsevier in European Journal of Radiology
- Vol. 75 (2) , 241-244
Facilitating cartilage volume measurement using MRI
- 31 August 2010
- Published by Elsevier in European Journal of Radiology
- Vol. 75 (2) , 241-244
Facilitating cartilage volume measurement using MRI
- 20 March 2008
- Published by Springer Nature in European Radiology
- Vol. 18 (7) , 1356-1363
Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy
The influence of various variables on the rate of pneumothorax and intrapulmonal hemorrhage associated with computed tomography (CT)-guided transthoracic needle biopsy of the lung were evaluated retrospectivly. One hundred and thirty-three patients underwent CT guided biopsy of a pulmonary lesion. Two patients were biopsied twice. Variables analyzed were lesion size, lesion location, number of pleural needle passes, lesion margin, length of intrapulmonal biopsy path and puncture time. Eighteen-gauge (18G) cutting needles (Trucut, Somatex, Teltow, Germany) were used for biopsy. Pneumothorax occured in 23 of 135 biopsies (17%). Chest tube placement was required in three out of 23 cases of pneumothorax (2% of all biopsies). Pneumothorax rate was significantly higher when the lesions were located in the lung parenchyma compared with locations at the pleura or chest wall (P < 0.05), but all pneumothorax cases which required chest tube treatment occured in lesions located less than 2 cm from the pleura. Longer puncture time led to an increase in pneumothorax rate (P < 0.05). Thirty-seven (27%) out of 135 biopsies showed perifocal hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage and pneumothorax (P < 0.05). Significantly more hemorrhage occured when the pleura was penetrated twice during the puncture (P < 0.05). Lesion size P < 0.05). Lesion margination showed no significant effect on complication rate. CT-guided biopsy of smaller lesions correlates with a higher bleeding rate. Puncture time should be minimized to reduce pneumothorax rate. Passing the pleura twice significantly increases the risk of hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage as well as pneumothorax.
- 20 March 2008
- Published by Springer Nature in European Radiology
- Vol. 18 (7) , 1356-1363
Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy
The influence of various variables on the rate of pneumothorax and intrapulmonal hemorrhage associated with computed tomography (CT)-guided transthoracic needle biopsy of the lung were evaluated retrospectivly. One hundred and thirty-three patients underwent CT guided biopsy of a pulmonary lesion. Two patients were biopsied twice. Variables analyzed were lesion size, lesion location, number of pleural needle passes, lesion margin, length of intrapulmonal biopsy path and puncture time. Eighteen-gauge (18G) cutting needles (Trucut, Somatex, Teltow, Germany) were used for biopsy. Pneumothorax occured in 23 of 135 biopsies (17%). Chest tube placement was required in three out of 23 cases of pneumothorax (2% of all biopsies). Pneumothorax rate was significantly higher when the lesions were located in the lung parenchyma compared with locations at the pleura or chest wall (P < 0.05), but all pneumothorax cases which required chest tube treatment occured in lesions located less than 2 cm from the pleura. Longer puncture time led to an increase in pneumothorax rate (P < 0.05). Thirty-seven (27%) out of 135 biopsies showed perifocal hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage and pneumothorax (P < 0.05). Significantly more hemorrhage occured when the pleura was penetrated twice during the puncture (P < 0.05). Lesion size P < 0.05). Lesion margination showed no significant effect on complication rate. CT-guided biopsy of smaller lesions correlates with a higher bleeding rate. Puncture time should be minimized to reduce pneumothorax rate. Passing the pleura twice significantly increases the risk of hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage as well as pneumothorax.
- 1 October 2006
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 41 (10) , 713-720
Navigation-Based Needle Puncture of a Cadaver Using a Hybrid Tracking Navigational System
The purpose of this study was to determine the puncture accuracy of a navigational system, Medarpa, in a soft tissue environment using augmented overlay imaging. Medarpa is an optical electromagnetic tracking system, which allows tracking of instruments, the radiologist’s head position, and the transparent display. The display superimposes a computed tomography scan of a cadaver chest on a human cadaver in real time. In group A, needle puncture was performed using the Medarpa system. Three targets located inside the cadaver chest were selected. In group B, the same targets were used to perform standard computed tomography-guided puncture using a single-slice technique. A total of 42 punctures were performed in each group. Postpuncture computed tomography scans were made to verify needle tip positions. Mean deviation from targets was 8.42 mm ± 1.78 mm for group A and 8.90 mm ± 1.71 mm for group B. No significant difference was found between group A and B in any target (P > 0.05). No significant difference was found between the targets of the same group (P > 0.05). Procedural time for 42 punctures was 160 minutes in group A versus 289 minutes in group B (P < 0.05). Needle puncture in a soft tissue environment using the navigational system Medarpa can be reliably performed and matches the accuracy achieved by a computed tomography-guided puncture technique.
- 1 October 2006
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 41 (10) , 713-720
Navigation-Based Needle Puncture of a Cadaver Using a Hybrid Tracking Navigational System
The purpose of this study was to determine the puncture accuracy of a navigational system, Medarpa, in a soft tissue environment using augmented overlay imaging. Medarpa is an optical electromagnetic tracking system, which allows tracking of instruments, the radiologist’s head position, and the transparent display. The display superimposes a computed tomography scan of a cadaver chest on a human cadaver in real time. In group A, needle puncture was performed using the Medarpa system. Three targets located inside the cadaver chest were selected. In group B, the same targets were used to perform standard computed tomography-guided puncture using a single-slice technique. A total of 42 punctures were performed in each group. Postpuncture computed tomography scans were made to verify needle tip positions. Mean deviation from targets was 8.42 mm ± 1.78 mm for group A and 8.90 mm ± 1.71 mm for group B. No significant difference was found between group A and B in any target (P > 0.05). No significant difference was found between the targets of the same group (P > 0.05). Procedural time for 42 punctures was 160 minutes in group A versus 289 minutes in group B (P < 0.05). Needle puncture in a soft tissue environment using the navigational system Medarpa can be reliably performed and matches the accuracy achieved by a computed tomography-guided puncture technique.
- 10 March 2006
- Published by Springer Nature in European Radiology
- Vol. 16 (8) , 1789-1795
Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool
The purpose of this study was to investigate a 3D coronary artery segmentation algorithm using 16-row MDCT data sets. Fifty patients underwent cardiac CT (Sensation 16, Siemens) and coronary angiography. Automatic and manual detection of coronary artery stenosis was performed. A 3D coronary artery segmentation algorithm (Fraunhofer Institute for Computer Graphics, Darmstadt) was used for automatic evaluation. All significant stenoses (>50%) in vessels >1.5 mm in diameter were protocoled. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of coronary angiography. Sensitivity and specificity were determined for automatic and manual detection as well as was the time for both CT-based evaluation methods. The overall sensitivity and specificity of the automatic and manual approach were 93.1 vs. 95.83% and 86.1 vs. 81.9%. The time required for automatic evaluation was significantly shorter than with the manual approach, i.e., 246.04±43.17 s for the automatic approach and 526.88±45.71 s for the manual approach (P<0.0001). In 94% of the coronary artery branches, automatic detection required less time than the manual approach. Automatic coronary vessel evaluation is feasible. It reduces the time required for cardiac CT evaluation with similar sensitivity and specificity as well as facilitates the evaluation of MDCT coronary angiography in a standardized fashion.
- 10 March 2006
- Published by Springer Nature in European Radiology
- Vol. 16 (8) , 1789-1795
Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool
The purpose of this study was to investigate a 3D coronary artery segmentation algorithm using 16-row MDCT data sets. Fifty patients underwent cardiac CT (Sensation 16, Siemens) and coronary angiography. Automatic and manual detection of coronary artery stenosis was performed. A 3D coronary artery segmentation algorithm (Fraunhofer Institute for Computer Graphics, Darmstadt) was used for automatic evaluation. All significant stenoses (>50%) in vessels >1.5 mm in diameter were protocoled. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of coronary angiography. Sensitivity and specificity were determined for automatic and manual detection as well as was the time for both CT-based evaluation methods. The overall sensitivity and specificity of the automatic and manual approach were 93.1 vs. 95.83% and 86.1 vs. 81.9%. The time required for automatic evaluation was significantly shorter than with the manual approach, i.e., 246.04±43.17 s for the automatic approach and 526.88±45.71 s for the manual approach (P<0.0001). In 94% of the coronary artery branches, automatic detection required less time than the manual approach. Automatic coronary vessel evaluation is feasible. It reduces the time required for cardiac CT evaluation with similar sensitivity and specificity as well as facilitates the evaluation of MDCT coronary angiography in a standardized fashion.
- 8 March 2005
- Published by Springer Nature in European Radiology
- Vol. 15 (11) , 2366-2374
Accuracy of biopsy needle navigation using the Medarpa system—computed tomography reality superimposed on the site of intervention
The aim of this work was to determine the accuracy of a new navigational system, Medarpa, with a transparent display superimposing computed tomography (CT) reality on the site of intervention. Medarpa uses an optical and an electromagnetic tracking system which allows tracking of instruments, the radiologist and the transparent display. The display superimposes a CT view of a phantom chest on a phantom chest model, in real time. In group A, needle positioning was performed using the Medarpa system. Three targets (diameter 1.5 mm) located inside the phantom were punctured. In group B, the same targets were used to perform standard CT-guided puncturing using the single-slice technique. The same needles were used in both groups (15 G, 15 cm). A total of 42 punctures were performed in each group. Post puncture, CT scans were made to verify needle tip positions. The mean deviation from the needle tip to the targets was 6.65±1.61 mm for group A (range 3.54–9.51 mm) and 7.05±1.33 mm for group B (range 4.10–9.45 mm). No significant difference was found between group A and group B for any target (p>0.05). No significant difference was found between the targets of the same group (p>0.05). The accuracy in needle puncturing using the augmented reality system, Medarpa, matches the accuracy achieved by CT-guided puncturing technique.
- 8 March 2005
- Published by Springer Nature in European Radiology
- Vol. 15 (11) , 2366-2374
Accuracy of biopsy needle navigation using the Medarpa system—computed tomography reality superimposed on the site of intervention
The aim of this work was to determine the accuracy of a new navigational system, Medarpa, with a transparent display superimposing computed tomography (CT) reality on the site of intervention. Medarpa uses an optical and an electromagnetic tracking system which allows tracking of instruments, the radiologist and the transparent display. The display superimposes a CT view of a phantom chest on a phantom chest model, in real time. In group A, needle positioning was performed using the Medarpa system. Three targets (diameter 1.5 mm) located inside the phantom were punctured. In group B, the same targets were used to perform standard CT-guided puncturing using the single-slice technique. The same needles were used in both groups (15 G, 15 cm). A total of 42 punctures were performed in each group. Post puncture, CT scans were made to verify needle tip positions. The mean deviation from the needle tip to the targets was 6.65±1.61 mm for group A (range 3.54–9.51 mm) and 7.05±1.33 mm for group B (range 4.10–9.45 mm). No significant difference was found between group A and group B for any target (p>0.05). No significant difference was found between the targets of the same group (p>0.05). The accuracy in needle puncturing using the augmented reality system, Medarpa, matches the accuracy achieved by CT-guided puncturing technique.
- 24 November 2004
- Published by Springer Nature in European Radiology
- Vol. 15 (2) , 305-311
MDCT of the proximal anastomoses created by nitinol implants in coronary artery bypass grafting: a retrospective two-observer evaluation
- 24 November 2004
- Published by Springer Nature in European Radiology
- Vol. 15 (2) , 305-311
MDCT of the proximal anastomoses created by nitinol implants in coronary artery bypass grafting: a retrospective two-observer evaluation
- 15 October 2004
- Published by Springer Nature in European Radiology
- Vol. 15 (1) , 118-126
Visualisation of non-invasive coronary bypass imaging: 4-row vs. 16-row multidetector computed tomography
The purpose of this study was to investigate the image quality of coronary artery bypass graft visualization in 4- and 16-row multidetector CT using multiple imaging reformations. One hundred sixteen patients underwent CT examination of the heart after receiving CABG. Group A (n=58) received 4-row MDCT; group B (n=58) received 16-row MDCT. Various bypass types such as LITA to LAD and venous grafts to the RCA and RCX were included in the study. A five-point Likert scale was used to grade image quality. Each bypass was reviewed under different imaging reformations: thin slap maximum intensity projection (MIP thin), multiplanar reformation (MPR) and volume rendering technique (VRT). Special attention was paid to the delineation of the distal anastomosis. Interobserver correlation was determined. From 289 bypass grafts examined, 279 (96.54%) were classified as patent and 10 (3.46%) as not patent. Except for the distal anastomosis, 16-row MDCT showed significantly better results for all segments of bypasses. Comparison of reformations within group A and B showed that MIP thin (P<0.05) and VRT (P<0.05) displayed better visualization as compared to MPR. Significantly better imaging of all bypass types is possible using 16-row MDCT as compared to 4-row MDCT. Assessment of the distal anastomosis yields no difference between 4- and 16-row technology.
- 15 October 2004
- Published by Springer Nature in European Radiology
- Vol. 15 (1) , 118-126
Visualisation of non-invasive coronary bypass imaging: 4-row vs. 16-row multidetector computed tomography
The purpose of this study was to investigate the image quality of coronary artery bypass graft visualization in 4- and 16-row multidetector CT using multiple imaging reformations. One hundred sixteen patients underwent CT examination of the heart after receiving CABG. Group A (n=58) received 4-row MDCT; group B (n=58) received 16-row MDCT. Various bypass types such as LITA to LAD and venous grafts to the RCA and RCX were included in the study. A five-point Likert scale was used to grade image quality. Each bypass was reviewed under different imaging reformations: thin slap maximum intensity projection (MIP thin), multiplanar reformation (MPR) and volume rendering technique (VRT). Special attention was paid to the delineation of the distal anastomosis. Interobserver correlation was determined. From 289 bypass grafts examined, 279 (96.54%) were classified as patent and 10 (3.46%) as not patent. Except for the distal anastomosis, 16-row MDCT showed significantly better results for all segments of bypasses. Comparison of reformations within group A and B showed that MIP thin (P<0.05) and VRT (P<0.05) displayed better visualization as compared to MPR. Significantly better imaging of all bypass types is possible using 16-row MDCT as compared to 4-row MDCT. Assessment of the distal anastomosis yields no difference between 4- and 16-row technology.
- 7 May 2004
- Published by Springer Nature in European Radiology
- Vol. 14 (8) , 1400-1405
Virtual endoscopy of the tracheo-bronchial system: sub-millimeter collimation with the 16-row multidetector scanner
The purpose of this study was to evaluate the scope of sub-millimeter collimation reconstruction parameters using 16-row computer tomography and ECG triggering on image quality in virtual bronchoscopy. Thirty-two patients (5 women, 27 men, mean age 66.6±1.4) who had been admitted for coronary artery bypass graft surgery underwent CT examination of the thorax (Sensation 16, Siemens, Inc., Forchheim, Germany). All patients were examined with 16×0.75-mm collimation. Image reconstruction was performed for two groups. In group A (n=32), slice thickness of 1.5 mm and an overlap of 0.75 mm were used. In group B (n=32), slice thickness of 0.75 mm and an overlap of 0.4 mm were applied. Retrospective ECG triggering was performed in all patients. The maximum order of recognizable bronchi was determined in each data set. In addition to assessing the maximum order of bronchial bifurcation, bronchial diameter was determined in truly perpendicular sections in each patient. For every segment proximal to a bifurcation, image quality was subjectively graded as poor (grade 1), moderate (grade 2) or good (grade 3). The observers were asked to identify the minimum cardiac movement ECG-triggered image sets assuming that they would be of better quality than the maximum cardiac movement ECG-triggered image sets. The Mann-Whitney U-test and the Fisher’s Exact Test were used for statistical evaluation. In group A, a mean of 4.8±0.2 bifurcations was ascertained vs. 6.5±0.3 bifurcations in group B [PPPPP=0.0007 (20/32); observer 2: P=0.008 (18/32)], but not in group A [observer 1: P=0.286 (13/32); observer 2: P=0.123 (16/32)]. Sub-millimeter collimation and minimum cardiac movement ECG-triggered data acquisition allow deeper penetration into the tracheo-bronchial system allowing visualization of the bronchial surface down to diameters below 5 mm in certain cases up to the eighth bifurcation. Along with an enhanced visualization as such, better image quality is acquired in all segments evaluated. Trade off between better image quality, of doubtful diagnostic consequence, and much higher irradiation dose must be made.
- 7 May 2004
- Published by Springer Nature in European Radiology
- Vol. 14 (8) , 1400-1405
Virtual endoscopy of the tracheo-bronchial system: sub-millimeter collimation with the 16-row multidetector scanner
The purpose of this study was to evaluate the scope of sub-millimeter collimation reconstruction parameters using 16-row computer tomography and ECG triggering on image quality in virtual bronchoscopy. Thirty-two patients (5 women, 27 men, mean age 66.6±1.4) who had been admitted for coronary artery bypass graft surgery underwent CT examination of the thorax (Sensation 16, Siemens, Inc., Forchheim, Germany). All patients were examined with 16×0.75-mm collimation. Image reconstruction was performed for two groups. In group A (n=32), slice thickness of 1.5 mm and an overlap of 0.75 mm were used. In group B (n=32), slice thickness of 0.75 mm and an overlap of 0.4 mm were applied. Retrospective ECG triggering was performed in all patients. The maximum order of recognizable bronchi was determined in each data set. In addition to assessing the maximum order of bronchial bifurcation, bronchial diameter was determined in truly perpendicular sections in each patient. For every segment proximal to a bifurcation, image quality was subjectively graded as poor (grade 1), moderate (grade 2) or good (grade 3). The observers were asked to identify the minimum cardiac movement ECG-triggered image sets assuming that they would be of better quality than the maximum cardiac movement ECG-triggered image sets. The Mann-Whitney U-test and the Fisher’s Exact Test were used for statistical evaluation. In group A, a mean of 4.8±0.2 bifurcations was ascertained vs. 6.5±0.3 bifurcations in group B [PPPPP=0.0007 (20/32); observer 2: P=0.008 (18/32)], but not in group A [observer 1: P=0.286 (13/32); observer 2: P=0.123 (16/32)]. Sub-millimeter collimation and minimum cardiac movement ECG-triggered data acquisition allow deeper penetration into the tracheo-bronchial system allowing visualization of the bronchial surface down to diameters below 5 mm in certain cases up to the eighth bifurcation. Along with an enhanced visualization as such, better image quality is acquired in all segments evaluated. Trade off between better image quality, of doubtful diagnostic consequence, and much higher irradiation dose must be made.
- 1 September 2003
- Published by Springer Nature in Surgical Endoscopy
- Vol. 17 (9) , 1496
First report on sequential totally endoscopic thymomectomy and adrenalectomy using computer-enhanced telemanipulation
Background: Laparoscopic adrenalectomy is considered the standard method for removal of benign adrenal tumors, regardless of hormone activity. Minimally invasive surgery for thymomectomy aims at limited approaches, avoiding complete sternotomy or large thoracotomy. Methods: We report on a case in which totally endoscopic thymomectomy and adrenal gland resection were performed sequentially using a computer-enhanced telemanipulation system within 3 weeks. Results: Operating time was 4.5 h for totally endoscopic adrenalectomy and 1.5 h for totally endoscopic thymomectomy. The patient was transferred to the normal ward on the day of operation after either procedure and had an uneventful recovery. Pathology yielded no malignancy in both cases. Conclusion: This report demonstrates the safety and feasibility of various totally endoscopic procedures performed sequentially.
- 1 September 2003
- Published by Springer Nature in Surgical Endoscopy
- Vol. 17 (9) , 1496
First report on sequential totally endoscopic thymomectomy and adrenalectomy using computer-enhanced telemanipulation
Background: Laparoscopic adrenalectomy is considered the standard method for removal of benign adrenal tumors, regardless of hormone activity. Minimally invasive surgery for thymomectomy aims at limited approaches, avoiding complete sternotomy or large thoracotomy. Methods: We report on a case in which totally endoscopic thymomectomy and adrenal gland resection were performed sequentially using a computer-enhanced telemanipulation system within 3 weeks. Results: Operating time was 4.5 h for totally endoscopic adrenalectomy and 1.5 h for totally endoscopic thymomectomy. The patient was transferred to the normal ward on the day of operation after either procedure and had an uneventful recovery. Pathology yielded no malignancy in both cases. Conclusion: This report demonstrates the safety and feasibility of various totally endoscopic procedures performed sequentially.