CMClaude R. Mallet

Claude R. Mallet

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Claude R. Mallet has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Screening Tool for the Direct Analysis of Marine and Freshwater Phycotoxins in Organic SPATT Extracts from the Chesapeake Bay

    by Michelle D. Onofrio, Claude R. Mallet, Allen R. Place, Juliette L. Smith

    Many detection methods for phycotoxins, bioactive compounds produced by harmful algae, focus on one compound or a class of related compounds. Multiple harmful algal species often co-occur in the environment, however, emphasizing the need to analyze for the presence of multiple groups of marine and freshwater phycotoxins in environmental samples, e.g., extracts from solid phase adsorption toxin tracking (SPATT). Two methods were developed to screen for 13 phycotoxins (microcystin-RR, -LR, -YR, azaspiracid-1, -2, karlotoxin 3, goniodomin A, brevetoxin-2, yessotoxin, pectenotoxin-2, dinophysistoxin-1, -2, and okadaic acid) in organic SPATT extracts using ultra-performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) equipped with a trapping dimension (trap) and at-column dilution (ACD). The performance of each compound under 36 combinations of chromatographic conditions was characterized, and two final methods, acidic and basic, were selected based on peak shapes, signal intensities, resolution, and the separation in time of positive and negative MS ionization modes. Injection volumes of up to 1 mL were possible through trap/ACD technology, resulting in limits of detection between 0.001 and 0.05 µg/L across the analytes. Benefits highlighted in this study, beyond the improved detection limits and co-detection of multiple toxin groups, include the ability to inject samples of 100% organic solvent, ensuring analyte stability and streamlining workflow through the elimination of laborious sample preparation steps.


  • Decreasing the uncertainty of peak assignments for the analysis of synthetic cathinones using multi-dimensional ultra-high performance liquid chromatography

    by Cecilia M. Ochoa, Peter Shoenmakers, Claude R. Mallet, Ira S. Lurie

    Peak assignment uncertainty using retention time is significantly reduced by the use of multi-dimensional ultra-high performance liquid chromatography.


  • Analysis of ketamine and xylazine in complex matrices using two‐dimensional liquid chromatography/tandem mass spectrometry

    by Malorie Mella, Brendan Schweitzer, Sabra Botch‐Jones, Claude Mallet

    Rationale: Analyzing tissue samples is routinely performed when liquid biological samples are not available for replicate analysis. Preparing complex matrices, such as tissue, for analysis can be time‐consuming. Traditional sample preparation methods typically begin with homogenization followed by a sample clean‐up step such as liquid‐liquid or solid‐phase extraction. Samples are typically eluted, evaporated and reconstituted prior to instrumental analysis. The aim of this project was to evaluate the utility of multi‐dimensional chromatography in reducing the amount of time from sample acquisition to analysis. Methods: Tissue specimens were homogenized using a ceramic beads shaker. Homogenates were then diluted and loaded onto a mixed mode solid‐phase sorbent. The sorbent was washed, and the final eluate was transferred directly to vials without evaporation or reconstitution steps. Analysis was performed using a two‐dimensional (2D) ultra‐performance liquid chromatography (UPLC) configuration with an At‐column dilution option coupled to a triple quadrupole mass spectrometer. The target analytes (xylazine and ketamine) were quantified under multiple reaction monitoring (MRM) using electrospray ionization (ESI) in positive mode. Results: The lowest limit of detection evaluated in this study was 0.01 ng/mL. The linear dynamic range utilized was 0.1 to 10 ng/mL. The concentrations for xylazine in their respective tissues ranged from 0 to 0.316 ng/mL. Ketamine concentrations ranged from 0 to 0.905 ng/mL. The overall time for sample preparation was reduced to 30 min. The total run time was 10 min. Conclusions: The use of multidimensional chromatography with At‐column‐dilution allows for significant reduction in sample preparation time. The concentrations determined in these samples highlight the need for sensitive analytical techniques with the ability to detect analyte concentrations at sub ng/mL.


  • Increasing Flexibility in Two-Dimensional Liquid Chromatography by Pulsed Elution of the First Dimension: A Proof of Concept

    by Simon S. Jakobsen, Jan H. Christensen, Sylvain Verdier, Claude R. Mallet, Nikoline J. Nielsen

    This work demonstrates the development of an online two-dimensional liquid chromatography (2D-LC) method where the first dimension column is eluted by a sequence of pulses of increasing eluotropic strength generated by the LC pumps (pulsed-elution 2D-LC). Between the pulses, the first dimension is kept in a no-elution state using low eluent strength. The eluate from the first dimension is actively modulated using trap columns and subsequently analyzed in the second dimension. We demonstrate that by tuning the length and eluotropic strength of the pulses, peaks with retention factors in water, kw, above 150 can be manipulated to elute in 3–4 pulses. The no-elution state can be kept for 1–10 min with only minor changes as to which and how many pulses the peaks elute in. Pulsed-elution 2D-LC combined with active modulation tackles three of the main challenges encountered in 2D-LC and specifically online comprehensive 2D-LC: undersampling, difficulties in refocusing, and lack of flexibility in the selection of column dimensions and flow rates because the two dimensions constrain each other. The pulsed-elution 2D-LC was applied for the analysis of a basic fraction of vacuum gas oil. Peak capacity was 4018 for a 540 min analysis and 4610 for a 1040 min analysis.


  • Illicit Drug Analysis Using Two-Dimension Liquid Chromatography/Tandem Mass Spectrometry

    by Claude Mallet, Sabra Botch-Jones

    For the identification of illicit drugs in forensic toxicological casework, analysis can be delayed and potentially compromised due to lengthy sample preparation techniques. For a complete forensic identification, a robust methodology is required and the current trend in forensic laboratories is the use of liquid chromatography coupled to mass spectrometry (LC/MS or LC/MS-MS). However, to achieve satisfactory results, extensive and time-consuming sample preparation protocols are required to reach sub-ng/mL levels. The concept of sequential 2D extraction was designed to capture the retention behavior of a target analyte in response to various extraction parameters. Therefore, optimized conditions can be selected to excise a region of interest during extraction. The utilization of multi-dimensional chromatography combined with a micro-extraction technique was evaluated to decrease sample preparation time while enhancing the separation integrity observed with current single-dimensional chromatography techniques. A wide range of illicit drugs were spiked in human urine and extracted using three extraction protocols for performance evaluation. The extraction process was performed using a reversed-phase solid phase extraction (SPE) in 1D, 2D-optimized, 2D-sequential and cumulative elution modes. The chosen 2D chromatography conditions that were used in this application were identified using a 6 × 6 automated methods development protocol (144 methods total). The extraction of urine samples containing target analytes was completed in less than 20 min. The analysis was performed using 200 µL of the final organic solvent (MeOH) extracts. The limit of detection for all drugs was measured at 100 pg/mL (ppt) from a 1 mL sample volume. Several analytes showed excellent signal at 10 pg/mL (ppt).


  • Top Cited Papers

    A study of ion suppression effects in electrospray ionization from mobile phase additives and solid‐phase extracts

    by Claude R. Mallet, Ziling Lu, Jeff R. Mazzeo

    Since the wide adoption of liquid chromatography/tandem mass spectrometry (LC/MS/MS), the ion suppression/enhancement phenomenon is the latest barrier to high‐throughput analysis. This consequence of a nonoptimized analytical method can lead to adverse effects during quantitation (i.e. poor accuracy and precision). Previous papers have reported that ion suppression is a direct result of endogenous material present in biological samples. However, in the case of a solid‐phase liquid chromatography/tandem mass spectrometry (SPE/LC/MS/MS) system, the measured result is the combination of several operating conditions and parameters. Little has been done to effectively monitor and/or choose optimized conditions for the complete sequence of extraction, clean up, separation and analysis. This paper describes a simple setup for quantification of ion suppression/enhancement. Several mobile phase additives, ion‐pairing agents and SPE extracts were measured and compared against a standard reference. The results demonstrated that a clean up of plasma extracts based on ion exchange leads to minimal ion suppression/enhancement for the compounds that were investigated. Copyright © 2003 John Wiley & Sons, Ltd.


  • Performance of an ultra‐low elution‐volume 96‐well plate: drug discovery and development applications

    by Claude R. Mallet, Ziling Lu, Ray Fisk, Jeffrey R. Mazzeo, Uwe D. Neue

    Recently, sample preparation has been considered to be the major cause of bottlenecks during high‐throughput analysis. With the assistance of robotic liquid handlers and the 96‐well plate format, more samples can be prepared for subsequent liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis. Protein precipitation is still widely used despite potential loss of sensitivity or variable results due to ion suppression. The use of solid‐phase extraction (SPE) clearly gives superior results but may not be as cost effective as protein precipitation due to the labor and material costs associated with the process. Here, a novel 96‐well SPE plate is described that was designed to minimize the elution volume required for quantitative elution of analytes. The plate is packed with 2 mg of a high‐capacity SPE sorbent that allows loading of up to 750 μL of plasma, while the novel design permits elution with as little as 25 μL. Therefore, the plate offers up to a 15‐fold increase in sample concentration. The evaporation and reconstitution step that is typically required in SPE is avoided due to the concentrating ability of the plate. Examples of applications in drug discovery/development are shown and results are compared to protein precipitation. Excellent sensitivity and linearity are demonstrated. Copyright © 2002 John Wiley & Sons, Ltd.


  • Analysis of a basic drug by on‐line solid‐phase extraction liquid chromatography/tandem mass spectrometry using a mixed mode sorbent

    by Claude R Mallet, Ziling Lu, Jeff Mazzeo, Uwe Neue

    Two on‐line configurations using multiple 6‐ and 10‐port valves were investigated for high‐flow on‐line extraction of a basic drug in rat plasma and human urine using a reversed‐phase and a cation‐exchange SPE sorbent. The first configuration studied was a single reversed‐phase extraction cartridge (2.1 × 20 mm, 25µm) using an optimized washing protocol. The results showed that up to 1.5 mL of sample (urine or plasma diluted 1:1) can be injected with limits of quantification (LOQs) as low as 100 pg/mL. The second configuration studied was the combination of a cation exchanger and a reversed‐phase cartridge using at‐column dilution. The results showed better LOQs than those obtained with the single cartridge at 10 pg/mL with the same injection volume. The mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. All calibration curves gave an average of 5% relative standard deviation (RSD). Copyright © 2002 John Wiley & Sons, Ltd.


  • Evaluation of several solid phase extraction liquid chromatography/tandem mass spectrometry on‐line configurations for high‐throughput analysis of acidic and basic drugs in rat plasma

    by Claude R. Mallet, Jeff R. Mazzeo, Uwe Neue

    Several configurations using 6‐ and 10‐port switching valves were studied for high flow, on‐line extraction of rat plasma coupled to an electrospray triple quadrupole mass spectrometer. Each plasma sample was diluted 1:1 with an aqueous internal standard solution. The sample was injected into a 2.1 × 20 mm cartridge column packed with 25 µm divinylbenzene/ N ‐vinylpyrrolidone packing using 100% aqueous mobile phase at 4 mL/min. After sample loading and sample cleanup, the analytes were eluted from the extraction column with a 1.0‐min gradient at 0.4 mL/min. The samples were either analyzed directly after elution from the extraction column or after additional separation using a short high performance liquid chromatography (HPLC) column. The different configurations were tested using an acidic drug (diflunisal) and a basic drug (clemastine) in rat plasma. On‐line analysis was performed by injecting 200 µL of diluted plasma. The mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. All calibration standards gave relative standard deviations (RSDs) below 5%. The total time per sample was 3 min. Copyright © 2001 John Wiley & Sons, Ltd.