AIAnders Ivarsen

Anders Ivarsen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anders Ivarsen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Jesper Hjortdal

    Aarhus University Hospital

    9 shared publications
  • Jesper Dmsci Hjortdal

    Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark

    1 shared publication
  • Jesper Ø. Hjortdal

    From the Department of Ophthalmology, Århus University Hospital, Århus, Denmark

    1 shared publication
  • Kristian Næser

    From the Departments of Ophthalmology, Aarhus University Hospital (Ivarsen, Næser, Hjortdal), Aarhus, and Randers Regional Hospital (Næser), Randers, Denmark

    1 shared publication
  • Niels Ehlers

    Department of Ophthalmology, Århus University Hospital, Århus, Denmark

    1 shared publication
  • Sven Asp

    Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark

    1 shared publication

Latest Publications

  • Decision-Making in Keratoplasty

    by Anders Ivarsen, Jesper Hjortdal

  • Clinical Results in High Myopia

    by Anders Ivarsen, Jesper Hjortdal

  • Correction of Myopic Astigmatism With Small Incision Lenticule Extraction

    by Anders Ivarsen, Jesper Hjortdal

    PURPOSE: To evaluate the outcome after small incision refractive lenticule extraction (SMILE) in patients with myopic astigmatism. METHODS: Seven hundred seventy-five eyes from 403 patients with myopia treated with SMILE for a cylinder of 0.75 diopters (D) or more were identified from patient records. Six hundred sixty-nine eyes were defined as receiving low (< 2.5 D) and 106 eyes as receiving high (⩾ 2.5 D) astigmatic correction. Patients were examined before and 3 months after surgery. SMILE was performed with a Visumax femtosecond laser (Carl Zeiss Meditec, Jena, Germany). Preoperative and postoperative refractions were converted to polar values. Induced torsion and achieved corrections of sphere and cylinder were determined. RESULTS: In low astigmatism, the mean preoperative spherical equivalent (SE) was −7.57 ±1.67 D and the cylinder was −1.22 ± 0.49 D. Three months after surgery, SE was −0.19 ± 0.48 D from target, astigmatism was 0.17 ± 0.42 D undercorrected, and a small but significant torsion of the cylinder axis corresponding to 0.05 ± 0.37 D was found. The astigmatic undercorrection measured 13% per diopter of attempted correction. In high astigmatism, preoperative SE was −5.91 ± 2.56 D and cylinder was −3.22 ± 0.67 D. After surgery, the average astigmatic undercorrection was 0.59 ± 0.65 D, equivalent to 16% per diopter of attempted correction. No undercorrection in SE occurred and no torsion was found. CONCLUSIONS: SMILE in myopic astigmatism offers predictable correction of SE, but a small, significant undercorrection of the astigmatic error. The undercorrection increases with the attempted treatment. Only very little rotation of the cylinder axis was found. [ J Refract Surg. 2014;30(4):240–247.]


  • Top Cited Papers

    Safety and Complications of More Than 1500 Small-Incision Lenticule Extraction Procedures

    by Anders Ivarsen, Sven Asp, Jesper Hjortdal


  • All-Femtosecond Laser Keratorefractive Surgery

    by Anders Ivarsen, Jesper Hjortdal

  • Collagen Cross-linking for Advanced Progressive Keratoconus

    by Anders Ivarsen, Jesper Dmsci Hjortdal

    Purpose: Collagen cross-linking (CXL) is a safe and effective procedure to stop progression of keratoconus. However, corneas with a maxK of more than 55 to 58 diopters (D) have been suggested to have an increased failure rate. We report results of CXL for progressive keratoconus in corneas with a maxK of 55 D or more. Methods: Retrospective follow-up. Twenty-eight eyes of 22 patients from 12 to 38 years were treated with CXL for progressive keratoconus. All patients had a preoperative maxK of at least 55 D. Patients were examined on 2 or more occasions after treatment, with a mean follow-up of 22 months. At all visits, patients received routine clinical examination with slit-lamp biomicroscopy, determination of corrected distance visual acuity (CDVA), and Pentacam tomography. Results: The average preoperative maxK was 61.2 ± 3.7 D. After CXL, maxK significantly decreased to 59.5 ± 3.7 D at the last recorded visit. In 27 eyes, keratoconic progression seemed to have stopped, and in 14 eyes maxK improved with more than 2.0 D decrease, whereas 1 eye showed an increase in maxK of more than 2.0 D. The average CDVA remained unchanged after CXL treatment, although 11 eyes improved and 2 eyes had an unexplained loss of CDVA. Conclusions: CXL treatment in eyes with advanced progressive keratoconus prevented further progression in 27 of 28 eyes. Progression in cases with advanced keratoconus should not exclude CXL as a treatment to preserve visual acuity or as a supplement to other treatment modalities to delay or avoid keratoplasty.


  • Laser in situ keratomileusis for high astigmatism in myopic and hyperopic eyes

    by Anders Ivarsen, Kristian Næser, Jesper Hjortdal

    To evaluate outcomes after laser in situ keratomileusis (LASIK) in highly astigmatic myopic and hyperopic eyes. University eye clinic. Retrospective case series. Eyes with more than 2.0 diopters (D) of astigmatism were identified from patient records. The mean preoperative cylinder was -3.92 D ± 0.82 (SD) in myopic eyes and -4.42 ± 1.10 D in hyperopic eyes. Patients were examined preoperatively and 3 months postoperatively. Laser in situ keratomileusis was performed with a Visumax femtosecond laser and a MEL-80 excimer laser. Preoperative and postoperative refractions were converted to polar values. Induced torsion and achieved correction of sphere and cylinder were determined. After 3 months, the mean sphere was 0.48 ± 0.68 D in myopic eyes and the mean cylinder -0.97 ± 0.52 D. Spherical equivalent (SE) correction was 0.05 ± 0.42 D from target. Astigmatism was 0.77 ± 0.62 D undercorrected (P<.01), and the mean induced torsion was -0.18 ± 0.51 D (P=.02). Astigmatic undercorrection was 21% of the intended correction. In hyperopia, the mean 3-month refraction was 0.79 ± 0.83 D in sphere and -1.38 ± 0.90 D in cylinder. The SE refraction was -0.01 ± 0.71 D from target. Astigmatism was 1.17 ± 0.81 D undercorrected (P<.01), with no significant torsion. Intended and achieved astigmatic corrections were correlated, with astigmatism being 28% undercorrected. Laser in situ keratomileusis in highly astigmatic eyes precisely corrected SE refraction but led to astigmatic undercorrection, particularly in hyperopia. Little to no torsion of the cylinder axis was induced.


  • Seven-Year Changes in Corneal Power and Aberrations after PRK or LASIK

    by Anders Ivarsen, Jesper Hjortdal

    Purpose. To examine long-term changes in corneal power and aberrations in myopic patients randomized to photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK). Methods. Forty-five patients with myopia from −6 to −8 diopters (spherical equivalent refraction) were randomized to PRK (n = 20) or LASIK (n = 25). Patients were examined preoperatively and for up to 7 years after surgery. Measurements included refraction, topography (TMS-1), and ultrasound pachymetry. By 3 years, 16 PRK and 15 LASIK patients were examined and by 7 years, 9 PRK and 7 LASIK subjects were available. Only patients who had not been reoperated and attended the two late controls were included in data analyses. Optical analysis of topographic data was used to calculate corneal power and wavefront aberrations. Results. PRK and LASIK caused a similar reduction in corneal power. During the first year after PRK, corneal power increased, but remained stable from 1 to 7 years. In contrast, corneal power continued to increase from 1 to 7 years after LASIK. Both PRK and LASIK caused an increase in coma-like and spherical aberrations that remained constant for 7 years. No significant changes in other higher-order aberrations were observed. Conclusions. The cornea may not be stable even 7 years after LASIK, as indicated by the continuing increase in corneal power. In contrast, PRK appears stable from 1 year post surgery. Coma-like and spherical aberrations are permanently increased after PRK and LASIK. (ClinicalTrials.gov number, NCT00404105.)


  • Comparison of two partial coherence interferometers for corneal pachymetry in high myopia and after LASIK

    by Anders Ivarsen, Niels Ehlers, Jesper Hjortdal

    : Purpose:  We aimed to compare the Haag‐Streit optical low‐coherence reflectometry (OLCR) pachymeter and the Zeiss Anterior Chamber Master (ACMaster) for measuring central corneal thickness (CCT) in high myopes and after laser in situ keratomileusis (LASIK) for myopia.Methods:  Central corneal thickness was measured in 55 eyes of 30 myopic subjects (spherical equivalent refraction of − 5.25 D to − 10.75 D, maximal astigmatism of − 2 D), and in 37 eyes of 21 patients 3 months after LASIK for myopia (preoperative spherical equivalent refraction of − 6.0 D to − 10.75 D, maximal astigmatism of − 2 D). All measurements were performed with the Haag‐Streit OLCR pachymeter and the Zeiss ACMaster, using group refractive indices of 1.376 and 1.3851, respectively. Thickness measurements were compared using paired t‐tests, Pearson’s correlation, linear regression and Bland−Altman plots.Results:  In myopic subjects, CCT measured 531 ± 28 μm and 533 ± 27 μm with the OLCR pachymeter and the ACMaster, respectively (p < 0.01); all measurements correlated closely (r = 0.99, p < 0.01). In LASIK‐treated eyes, CCT measured 472 ± 24 μm using the OLCR pachymeter and 475 ± 23 μm using the ACMaster (p < 0.01), again with close correlation between the two instruments (r = 0.99, p < 0.01).Conclusions:  Measurements of CCT in high myopes and after myopic LASIK were very similar with the Haag‐Streit OLCR pachymeter and the Zeiss ACMaster. Using the current group refractive indices, the observed difference between the two instruments of < 3 μm is of little clinical importance. Thus, it would seem safe to use the OLCR pachymeter and the ACMaster interchangeably for CCT measurements in myopia as well as after myopic LASIK.