Philipp Steven
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Philipp Steven has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Gereon Hüttmann
Institute of Biomedical Optics, Universität zu Lübeck, Lübeck, Germany
2 shared publications Christian Rose
University Medical Center of Schleswig-Holstein, Department of Dermatology, Ratzeburger Allee 160, Luebeck 23538 Germany
1 shared publicationMarina Hovakimyan
1 shared publicationMaya Müller
University Medical Center of Schleswig-Holstein, Department of Ophthalmology, Ratzeburger Allee 160, Luebeck 23538 Germany
1 shared publicationNorbert Koop
University of Luebeck, Institute of Biomedical Optics, Peter-Monnik-Weg 4, Luebeck 23562 Germany
1 shared publicationOliver Stachs
1 shared publication
Latest Publications
- 1 December 2010
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 36 (12) , 2150-2159
Imaging corneal crosslinking by autofluorescence 2-photon microscopy, second harmonic generation, and fluorescence lifetime measurements
To evaluate the use of 2-photon microscopy (TPM), which excites tissue autofluorescence, in detecting and calculating the grade of collagen corneal crosslinks, which are not visible through the slitlamp and in vivo confocal microscopy. Departments of Ophthalmology, University of Lübeck, Lübeck, and University of Rostock, Rostock, Germany. Experimental study. Corneas of rabbits were treated with different crosslinking (CXL) protocols. Two weeks after treatment, the corneas were evaluated in vivo by confocal microscopy. Eyes were enucleated and TPM was performed at 710 nm and 826 nm excitation wavelengths to detect tissue autofluorescence, second harmonic generation, and fluorescence lifetime measurements (FLIM). Eyes were then fixed and analyzed by histology. Crosslinking following the standard protocol generated a strong autofluorescence signal in the stroma that was detected by TPM. This signal was weakly present in the control specimens, and a sharp transition zone between the peripheral zone and the CXL zone was seen. On FLIM, an increase in corneal crosslinks was measured when the standard protocol was used. Two-photon microscopy, a noninvasive method, was able to detect the effects of therapeutic CXL and measure the grade of CXL. In addition to postoperative treatment control, the technique has possibilities for use in online dosimetry during 2-photon triggered CXL.
- 1 December 2010
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 36 (12) , 2150-2159
Imaging corneal crosslinking by autofluorescence 2-photon microscopy, second harmonic generation, and fluorescence lifetime measurements
To evaluate the use of 2-photon microscopy (TPM), which excites tissue autofluorescence, in detecting and calculating the grade of collagen corneal crosslinks, which are not visible through the slitlamp and in vivo confocal microscopy. Departments of Ophthalmology, University of Lübeck, Lübeck, and University of Rostock, Rostock, Germany. Experimental study. Corneas of rabbits were treated with different crosslinking (CXL) protocols. Two weeks after treatment, the corneas were evaluated in vivo by confocal microscopy. Eyes were enucleated and TPM was performed at 710 nm and 826 nm excitation wavelengths to detect tissue autofluorescence, second harmonic generation, and fluorescence lifetime measurements (FLIM). Eyes were then fixed and analyzed by histology. Crosslinking following the standard protocol generated a strong autofluorescence signal in the stroma that was detected by TPM. This signal was weakly present in the control specimens, and a sharp transition zone between the peripheral zone and the CXL zone was seen. On FLIM, an increase in corneal crosslinks was measured when the standard protocol was used. Two-photon microscopy, a noninvasive method, was able to detect the effects of therapeutic CXL and measure the grade of CXL. In addition to postoperative treatment control, the technique has possibilities for use in online dosimetry during 2-photon triggered CXL.
- 1 January 2009
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 14 (6) , 064040-064040-8
Comparison of Cornea Module and DermaInspect for noninvasive imaging of ocular surface pathologies
Minimally invasive imaging of ocular surface pathologies aims at securing clinical diagnosis without actual tissue probing. For this matter, confocal microscopy (Cornea Module) is in daily use in ophthalmic practice. Multiphoton microscopy is a new optical technique that enables high-resolution imaging and functional analysis of living tissues based on tissue autofluorescence. This study was set up to compare the potential of a multiphoton microscope (DermaInspect) to the Cornea Module. Ocular surface pathologies such as pterygia, papillomae, and nevi were investigated in vivo using the Cornea Module and imaged immediately after excision by DermaInspect. Two excitation wavelengths, fluorescence lifetime imaging and second-harmonic generation (SHG), were used to discriminate different tissue structures. Images were compared with the histopathological assessment of the samples. At wavelengths of , multiphoton microscopy exclusively revealed cellular structures. Collagen fibrils were specifically demonstrated by second-harmonic generation. Measurements of fluorescent lifetimes enabled the highly specific detection of goblet cells, erythrocytes, and nevus-cell clusters. At the settings used, DermaInspect reaches higher resolutions than the Cornea Module and obtains additional structural information. The parallel detection of multiphoton excited autofluorescence and confocal imaging could expand the possibilities of minimally invasive investigation of the ocular surface toward functional analysis at higher resolutions.- 1 January 2009
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 14 (6) , 064040-064040-8
Comparison of Cornea Module and DermaInspect for noninvasive imaging of ocular surface pathologies
Minimally invasive imaging of ocular surface pathologies aims at securing clinical diagnosis without actual tissue probing. For this matter, confocal microscopy (Cornea Module) is in daily use in ophthalmic practice. Multiphoton microscopy is a new optical technique that enables high-resolution imaging and functional analysis of living tissues based on tissue autofluorescence. This study was set up to compare the potential of a multiphoton microscope (DermaInspect) to the Cornea Module. Ocular surface pathologies such as pterygia, papillomae, and nevi were investigated in vivo using the Cornea Module and imaged immediately after excision by DermaInspect. Two excitation wavelengths, fluorescence lifetime imaging and second-harmonic generation (SHG), were used to discriminate different tissue structures. Images were compared with the histopathological assessment of the samples. At wavelengths of , multiphoton microscopy exclusively revealed cellular structures. Collagen fibrils were specifically demonstrated by second-harmonic generation. Measurements of fluorescent lifetimes enabled the highly specific detection of goblet cells, erythrocytes, and nevus-cell clusters. At the settings used, DermaInspect reaches higher resolutions than the Cornea Module and obtains additional structural information. The parallel detection of multiphoton excited autofluorescence and confocal imaging could expand the possibilities of minimally invasive investigation of the ocular surface toward functional analysis at higher resolutions.