Carlos G. Arce
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carlos G. Arce has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Diane R. M.D. Marinho
Department of Ophthalmology, Hospital de Clínicas de Porto Alegre, Federal University of Rio Grande do Sul, São Paulo, Brazil
1 shared publication Eduardo J. Maidana
1 shared publicationEduardo S. Soriano
1 shared publicationJuan B. Alzamora
1 shared publicationKarolinne M. Rocha
1 shared publicationKenneth Himmel
1 shared publication
Latest Publications
- 29 March 2012
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 250 (7) , 1029-1034
Orbscan II and double-K method for IOL calculation after refractive surgery
Background Precise IOL calculation in post-refractive surgery patients is still a challenge for the cataract surgeon. The purpose of this study is to test whether adding Orbscan II values into the double-K method improves IOL calculation in this group of patients. Methods A prospective study with 43 eyes previously submitted to refractive surgery that underwent cataract extraction. IOL calculation was performed with double-K method. Post-K value was derived from Orbscan total-mean power map. The average corneal curvature of the general population (43.8D) was used as the pre-K value. Refraction results 30 days after surgery were compared with refraction that would be obtained if we used: (1) post-K values from keratometry, (2) post-K values from topography, and (3) pre-K values from Orbscan total-mean power. Anterior chamber depth measures obtained with the IOL Master and Orbscan II were compared. Results Mean postoperative spherical equivalent (SE) was −0.25 ± 1.10 D in eyes submitted to radial keratotomy , –1.04 ± 1.42 D in eyes previously submitted to myopic Lasik, and +0.05 ± 1.76 D in those submitted to hyperopic surgeries. Had we inputted post-K values derived from keratometer and from topography, we would have obtained significantly higher postoperative refractive errors in eyes previously submitted to myopic refractive surgery (p < 0.05). Refractions using pre-K derived from the central 8 mm Orbscan instead of 43.8 D were similar in all studied groups (p > 0.05). Anterior chamber depth measured with IOL Master or Orbscan were similar. Conclusions Orbscan measurements used as the post-K values into the double-K method provide a precise IOL calculation, especially in post myopic refractive surgery patients.
- 29 March 2012
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 250 (7) , 1029-1034
Orbscan II and double-K method for IOL calculation after refractive surgery
Background Precise IOL calculation in post-refractive surgery patients is still a challenge for the cataract surgeon. The purpose of this study is to test whether adding Orbscan II values into the double-K method improves IOL calculation in this group of patients. Methods A prospective study with 43 eyes previously submitted to refractive surgery that underwent cataract extraction. IOL calculation was performed with double-K method. Post-K value was derived from Orbscan total-mean power map. The average corneal curvature of the general population (43.8D) was used as the pre-K value. Refraction results 30 days after surgery were compared with refraction that would be obtained if we used: (1) post-K values from keratometry, (2) post-K values from topography, and (3) pre-K values from Orbscan total-mean power. Anterior chamber depth measures obtained with the IOL Master and Orbscan II were compared. Results Mean postoperative spherical equivalent (SE) was −0.25 ± 1.10 D in eyes submitted to radial keratotomy , –1.04 ± 1.42 D in eyes previously submitted to myopic Lasik, and +0.05 ± 1.76 D in those submitted to hyperopic surgeries. Had we inputted post-K values derived from keratometer and from topography, we would have obtained significantly higher postoperative refractive errors in eyes previously submitted to myopic refractive surgery (p < 0.05). Refractions using pre-K derived from the central 8 mm Orbscan instead of 43.8 D were similar in all studied groups (p > 0.05). Anterior chamber depth measured with IOL Master or Orbscan were similar. Conclusions Orbscan measurements used as the post-K values into the double-K method provide a precise IOL calculation, especially in post myopic refractive surgery patients.
- 1 December 2009
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 25 (12) , 1061-1074
Calculation of Intraocular Lens Power Using Orbscan II Quantitative Area Topography After Corneal Refractive Surgery
Purpose: To present the prospective application of the Orbscan II central 2-mm total-mean corneal power obtained by quantitative area topography in intraocular lens (IOL) calculation after refractive surgery. Methods: Calculated and achieved refraction and the difference between them were studied in 77 eyes of 61 patients with previous radial keratotomy (RK), RK and additional surgeries, myopic LASIK, myopic photo-refractive keratectomy (PRK), or hyperopic LASIK who underwent phacoemulsification without complications in 3 eye centers. All IOL calculations used the average from the central 2-mm Orbscan II total-mean power of maps centered on the pupil without the use of previous refractive data. Six IOL styles implanted within the bag were used. Results: Using the SRK-T formula, the overall calculated refraction was −0.64±0.93 diopters (D). The overall achieved spherical equivalent refraction (−0.52±0.79 D; range: −3.12 to 1.25 D; 95% confidence interval [CI]: −0.70/−0.34 D) was ±0.50 D in 53% of eyes, ±1.00 D in 78% of eyes, and ±2.00 D in 99% of eyes. The overall difference between the calculated and achieved refraction (0.12±0.93 D, P =.27; range: −2.18 to 2.62 D; 95% CI: 0.09/0.33 D) was ±0.50 D in 39% of eyes, ±1.00 D in 77% of eyes, and ±2.00 D in 96% of eyes. This difference was ±1.00 D in 77% of eyes with RK ( P =.70), 82% of eyes with myopic LASIK ( P =.34), and 90% of eyes with myopic PRK ( P =.96). In eyes with RK followed by LASIK, a trend toward undercorrection was noted ( P =.03). In eyes with hyperopic LASIK, a trend toward overcorrection was noted ( P =.005). Conclusions: In eyes with previous corneal refractive surgery, IOL power calculation can be performed with reasonable accuracy using the Orbscan II central 2-mm total-mean power. This method had better outcomes in eyes with previous RK, myopic LASIK, and myopic PRK than in eyes with hyperopic LASIK or RK with LASIK. [ J Refract Surg . 2009;25:1061–1074.]
- 1 December 2009
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 25 (12) , 1061-1074
Calculation of Intraocular Lens Power Using Orbscan II Quantitative Area Topography After Corneal Refractive Surgery
Purpose: To present the prospective application of the Orbscan II central 2-mm total-mean corneal power obtained by quantitative area topography in intraocular lens (IOL) calculation after refractive surgery. Methods: Calculated and achieved refraction and the difference between them were studied in 77 eyes of 61 patients with previous radial keratotomy (RK), RK and additional surgeries, myopic LASIK, myopic photo-refractive keratectomy (PRK), or hyperopic LASIK who underwent phacoemulsification without complications in 3 eye centers. All IOL calculations used the average from the central 2-mm Orbscan II total-mean power of maps centered on the pupil without the use of previous refractive data. Six IOL styles implanted within the bag were used. Results: Using the SRK-T formula, the overall calculated refraction was −0.64±0.93 diopters (D). The overall achieved spherical equivalent refraction (−0.52±0.79 D; range: −3.12 to 1.25 D; 95% confidence interval [CI]: −0.70/−0.34 D) was ±0.50 D in 53% of eyes, ±1.00 D in 78% of eyes, and ±2.00 D in 99% of eyes. The overall difference between the calculated and achieved refraction (0.12±0.93 D, P =.27; range: −2.18 to 2.62 D; 95% CI: 0.09/0.33 D) was ±0.50 D in 39% of eyes, ±1.00 D in 77% of eyes, and ±2.00 D in 96% of eyes. This difference was ±1.00 D in 77% of eyes with RK ( P =.70), 82% of eyes with myopic LASIK ( P =.34), and 90% of eyes with myopic PRK ( P =.96). In eyes with RK followed by LASIK, a trend toward undercorrection was noted ( P =.03). In eyes with hyperopic LASIK, a trend toward overcorrection was noted ( P =.005). Conclusions: In eyes with previous corneal refractive surgery, IOL power calculation can be performed with reasonable accuracy using the Orbscan II central 2-mm total-mean power. This method had better outcomes in eyes with previous RK, myopic LASIK, and myopic PRK than in eyes with hyperopic LASIK or RK with LASIK. [ J Refract Surg . 2009;25:1061–1074.]