CACarlos G. Arce

Carlos G. Arce

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Carlos G. Arce has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Orbscan II and double-K method for IOL calculation after refractive surgery

    by Sérgio Kwitko, Diane R. Marinho, Samuel Rymer, Norton Severo, Carlos G. Arce

    Background Precise IOL calculation in post-refractive surgery patients is still a challenge for the cataract surgeon. The purpose of this study is to test whether adding Orbscan II values into the double-K method improves IOL calculation in this group of patients. Methods A prospective study with 43 eyes previously submitted to refractive surgery that underwent cataract extraction. IOL calculation was performed with double-K method. Post-K value was derived from Orbscan total-mean power map. The average corneal curvature of the general population (43.8D) was used as the pre-K value. Refraction results 30 days after surgery were compared with refraction that would be obtained if we used: (1) post-K values from keratometry, (2) post-K values from topography, and (3) pre-K values from Orbscan total-mean power. Anterior chamber depth measures obtained with the IOL Master and Orbscan II were compared. Results Mean postoperative spherical equivalent (SE) was −0.25 ± 1.10 D in eyes submitted to radial keratotomy , –1.04 ± 1.42 D in eyes previously submitted to myopic Lasik, and +0.05 ± 1.76 D in those submitted to hyperopic surgeries. Had we inputted post-K values derived from keratometer and from topography, we would have obtained significantly higher postoperative refractive errors in eyes previously submitted to myopic refractive surgery (p < 0.05). Refractions using pre-K derived from the central 8 mm Orbscan instead of 43.8 D were similar in all studied groups (p > 0.05). Anterior chamber depth measured with IOL Master or Orbscan were similar. Conclusions Orbscan measurements used as the post-K values into the double-K method provide a precise IOL calculation, especially in post myopic refractive surgery patients.


  • Calculation of Intraocular Lens Power Using Orbscan II Quantitative Area Topography After Corneal Refractive Surgery

    by Carlos G. Arce, Eduardo S. Soriano, Robert W. Weisenthal, Stephen M. Hamilton, Karolinne M. Rocha, Juan B. Alzamora, Eduardo J. Maidana, Vijayalakshmi L. Vadrevu, Kenneth Himmel, Paulo Schor, et al.

    Purpose: To present the prospective application of the Orbscan II central 2-mm total-mean corneal power obtained by quantitative area topography in intraocular lens (IOL) calculation after refractive surgery. Methods: Calculated and achieved refraction and the difference between them were studied in 77 eyes of 61 patients with previous radial keratotomy (RK), RK and additional surgeries, myopic LASIK, myopic photo-refractive keratectomy (PRK), or hyperopic LASIK who underwent phacoemulsification without complications in 3 eye centers. All IOL calculations used the average from the central 2-mm Orbscan II total-mean power of maps centered on the pupil without the use of previous refractive data. Six IOL styles implanted within the bag were used. Results: Using the SRK-T formula, the overall calculated refraction was −0.64±0.93 diopters (D). The overall achieved spherical equivalent refraction (−0.52±0.79 D; range: −3.12 to 1.25 D; 95% confidence interval [CI]: −0.70/−0.34 D) was ±0.50 D in 53% of eyes, ±1.00 D in 78% of eyes, and ±2.00 D in 99% of eyes. The overall difference between the calculated and achieved refraction (0.12±0.93 D, P =.27; range: −2.18 to 2.62 D; 95% CI: 0.09/0.33 D) was ±0.50 D in 39% of eyes, ±1.00 D in 77% of eyes, and ±2.00 D in 96% of eyes. This difference was ±1.00 D in 77% of eyes with RK ( P =.70), 82% of eyes with myopic LASIK ( P =.34), and 90% of eyes with myopic PRK ( P =.96). In eyes with RK followed by LASIK, a trend toward undercorrection was noted ( P =.03). In eyes with hyperopic LASIK, a trend toward overcorrection was noted ( P =.005). Conclusions: In eyes with previous corneal refractive surgery, IOL power calculation can be performed with reasonable accuracy using the Orbscan II central 2-mm total-mean power. This method had better outcomes in eyes with previous RK, myopic LASIK, and myopic PRK than in eyes with hyperopic LASIK or RK with LASIK. [ J Refract Surg . 2009;25:1061–1074.]