John N. Oshinski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
John N. Oshinski has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
A P Yoganathan
1 shared publicationBlake E. Larson
School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
1 shared publicationChristos P. Markou
The Departments of Radiology and Hematology, Emory University School of Medicine, Atlanta, Georgia
1 shared publicationDavid N. Ku
School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
1 shared publicationG P Chatzimavroudis
Cardiovascular Fluid Mechanics Laboratory, School of Chemical Engineering, Georgia Institute of Technology, Atlanta 30332-0100, USA
1 shared publicationHarris L. Bergman
School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
1 shared publication
Latest Publications
- 1 June 1998
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 14 (3) , 191-199
Magnetic resonance coronary angiography using navigator echo gated real-time slice following
Navigator echo gating allows for the elimination of breath-holding in MR imaging by providing a real-time monitor of respiratory position to gate image acquisition. In this study we examined the...
- 1 June 1998
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 14 (3) , 191-199
Magnetic resonance coronary angiography using navigator echo gated real-time slice following
Navigator echo gating allows for the elimination of breath-holding in MR imaging by providing a real-time monitor of respiratory position to gate image acquisition. In this study we examined the...
- 1 January 1998
- Vol. 7 (1) , 94-101
Quantification of the aortic regurgitant volume with magnetic resonance phase velocity mapping: a clinical investigation of the importance of imaging slice location.
Current techniques for assessment of aortic regurgitation (AR) are mainly qualitative. Magnetic resonance phase velocity mapping (PVM) provides accurate measurements of arterial blood blow. In AR, the aortic regurgitant volume (ARV) can be quantified with a single imaging slice measurement in the ascending aorta. The aim was to use PVM to: (i) quantify the regurgitant volume in patients with AR using an in vitro validated technique; and (ii) confirm in vivo our previous in vitro findings of the importance of measurement location. Four healthy volunteers and 19 patients with AR, varying from mild to severe, were examined in a 1.5 Tesla MRI scanner. In 13 patients, the slice was placed: (i) between the aortic valve and the coronary ostia; (ii) at the sinotubular junction (SJ); and (iii) 2 cm above the SJ. In six patients, one measurement was taken as close as technically possible to the aortic valve. PVM measurements of the ARV were compared with angiographic/echocardiographic AR grading. No ARV was measured in healthy subjects. In patients, PVM results correlated well with angiographic/echocardiographic data. Repeatability of the PVM results was excellent and interobserver variability very small. The measured ARV decreased as the slice distance from the aortic valve increased, due to aortic compliance, in agreement to previous in vitro results. Close to the valve, acceleration did not affect the accuracy of velocity measurements. PVM has great potential to measure AR in a purely quantitative manner. Measurement location is important and results suggest that the closer the measurement to the valve the more accurate the ARV quantification.
- 1 January 1998
- Vol. 7 (1) , 94-101
Quantification of the aortic regurgitant volume with magnetic resonance phase velocity mapping: a clinical investigation of the importance of imaging slice location.
Current techniques for assessment of aortic regurgitation (AR) are mainly qualitative. Magnetic resonance phase velocity mapping (PVM) provides accurate measurements of arterial blood blow. In AR, the aortic regurgitant volume (ARV) can be quantified with a single imaging slice measurement in the ascending aorta. The aim was to use PVM to: (i) quantify the regurgitant volume in patients with AR using an in vitro validated technique; and (ii) confirm in vivo our previous in vitro findings of the importance of measurement location. Four healthy volunteers and 19 patients with AR, varying from mild to severe, were examined in a 1.5 Tesla MRI scanner. In 13 patients, the slice was placed: (i) between the aortic valve and the coronary ostia; (ii) at the sinotubular junction (SJ); and (iii) 2 cm above the SJ. In six patients, one measurement was taken as close as technically possible to the aortic valve. PVM measurements of the ARV were compared with angiographic/echocardiographic AR grading. No ARV was measured in healthy subjects. In patients, PVM results correlated well with angiographic/echocardiographic data. Repeatability of the PVM results was excellent and interobserver variability very small. The measured ARV decreased as the slice distance from the aortic valve increased, due to aortic compliance, in agreement to previous in vitro results. Close to the valve, acceleration did not affect the accuracy of velocity measurements. PVM has great potential to measure AR in a purely quantitative manner. Measurement location is important and results suggest that the closer the measurement to the valve the more accurate the ARV quantification.