Ulrich H Thome
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ulrich H Thome has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Aileen Bischoff
Section of Neonatology and Pediatric Critical Care Medicine, University Hospital for Children and Adolescents, University of Ulm, 89075 Ulm, Germany
1 shared publicationAndreas Trotter
Section of Neonatology and Pediatric Critical Care Medicine, University Hospital for Children and Adolescents, University of Ulm, 89075 Ulm, Germany
1 shared publicationF Pohlandt
Division of Neonatology and Pediatric Critical Care, University Hospital for Children and Adolescents, University of Ulm, Germany
1 shared publicationFrank Pohlandt
Section of Neonatology and Pediatric Critical Care Medicine, University Hospital for Children and Adolescents, University of Ulm, 89075 Ulm, Germany
1 shared publicationLudwig Maier
Pharmacy, University of Ulm, 89069 Ulm, Germany
1 shared publicationW A Carlo
Division of Neonatology, Department of Pediatrics, University of Alabama at Birmingham, AL, USA
1 shared publication
Latest Publications
- 1 November 2006
- Published by Springer Nature in Pediatric Research
- Vol. 60 (5) , 619-623
Amiloride-Sensitive Nasal Potential Difference Is Not Changed by Estradiol and Progesterone Replacement But Relates to BPD or Death in a Randomized Trial on Preterm Infants
- 1 November 2006
- Published by Springer Nature in Pediatric Research
- Vol. 60 (5) , 619-623
Amiloride-Sensitive Nasal Potential Difference Is Not Changed by Estradiol and Progesterone Replacement But Relates to BPD or Death in a Randomized Trial on Preterm Infants
- Open Access
- 7 June 2005
- Published by BMJ in Archives of Disease in Childhood - Fetal and Neonatal Edition
- Vol. 90 (6) , F466-F473
Ventilation strategies and outcome in randomised trials of high frequency ventilation
Objective: Randomised controlled trials comparing elective use of high frequency ventilation (HFV) with conventional mechanical ventilation (CMV) in preterm infants have yielded conflicting results. We hypothesised that the variability of results may be explained by differences in study design, ventilation strategies, delay in initiation of HFV, and use of permissive hypercapnia. Methods: Randomised controlled trials comparing the elective use of HFV with any form of CMV were identified. Trials were classified according to the ventilation strategies used for HFV and CMV and oscillator device employed. For cumulative meta-analyses, trials were arranged by the following covariables: mean duration until randomisation, Paco2 limits, publication date, and sample size. Odds ratios (OR) and 95% confidence intervals were calculated using fixed and random effects models. Results: Seventeen randomised trials enrolling 3776 patients were included. Unlike previous meta-analyses, there was no significant difference in the incidence of bronchopulmonary dysplasia or death (OR 0.87, 0.75–1.00) and severe intraventricular haemorrhage grade 3–4 (1.14, 0.96–1.37). The incidence of air leaks (OR 1.23, 1.06–1.44) was significantly increased with HFV. Subgroup analyses and cumulative meta-analyses demonstrated that trial results were related to the ventilation strategies used for HFV and CMV. No influence was found for mean time to randomisation, degree of permissive hypercapnia, or sample size. Conclusions: Heterogeneity among trials of elective HFV compared to CMV in preterm infants is mainly due to differences in ventilatory strategies. Optimising CMV strategy appeared to be as effective as using HFV in improving pulmonary outcome in preterm infants.
- 7 June 2005
- Published by BMJ in Archives of Disease in Childhood - Fetal and Neonatal Edition
- Vol. 90 (6) , F466-F473
Open AccessVentilation strategies and outcome in randomised trials of high frequency ventilation
Objective: Randomised controlled trials comparing elective use of high frequency ventilation (HFV) with conventional mechanical ventilation (CMV) in preterm infants have yielded conflicting results. We hypothesised that the variability of results may be explained by differences in study design, ventilation strategies, delay in initiation of HFV, and use of permissive hypercapnia. Methods: Randomised controlled trials comparing the elective use of HFV with any form of CMV were identified. Trials were classified according to the ventilation strategies used for HFV and CMV and oscillator device employed. For cumulative meta-analyses, trials were arranged by the following covariables: mean duration until randomisation, Paco2 limits, publication date, and sample size. Odds ratios (OR) and 95% confidence intervals were calculated using fixed and random effects models. Results: Seventeen randomised trials enrolling 3776 patients were included. Unlike previous meta-analyses, there was no significant difference in the incidence of bronchopulmonary dysplasia or death (OR 0.87, 0.75–1.00) and severe intraventricular haemorrhage grade 3–4 (1.14, 0.96–1.37). The incidence of air leaks (OR 1.23, 1.06–1.44) was significantly increased with HFV. Subgroup analyses and cumulative meta-analyses demonstrated that trial results were related to the ventilation strategies used for HFV and CMV. No influence was found for mean time to randomisation, degree of permissive hypercapnia, or sample size. Conclusions: Heterogeneity among trials of elective HFV compared to CMV in preterm infants is mainly due to differences in ventilatory strategies. Optimising CMV strategy appeared to be as effective as using HFV in improving pulmonary outcome in preterm infants.