Wan-Kuen Jo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wan-Kuen Jo has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Kun-Ho Park
Department of Environmental Engineering, Kyungpook National University, Taegu, Korea
2 shared publicationsC.W. Nam
Department of Environmental Engineering, Kyungpook National University, Sankeok-dong, Bukgu, Taegu 702-701, South Korea
1 shared publicationChan-Woo Nam
Department of Environmental Engineering , Kyungpook National University , Taegu , Korea
1 shared publicationI.H. Yoon
Department of Earth Science, Kyungpook National University, Sankeok-dong, Bukgu, Taegu 702-701, South Korea
1 shared publicationKu-Won Pack
Department of Environmental Engineering, Kyungpook National University, Taegu, 702-701, Korea
1 shared publicationKung-Cho Moon
Department of Environmental Engineering, Kyungpook National University, Sankeok-dong, Bukgu, Taegu 702-701, South Korea
1 shared publication
Latest Publications
- 1 July 2001
- Published by Taylor & Francis in AIHA Journal
- Vol. 62 (4) , 466-471
Worker Exposure to Aromatic Volatile Organic Compounds in Dry Cleaning Stores
This study evaluated worker exposure to aromatic compounds and perchloroethylene (PERC) in dry cleaning stores relative to four different solvents. For benzene and toluene, there was no significant difference among the indoor air concentrations of the four different solvents. For ethylbenzene, m,p-xylene, and o-xylene, the air concentrations were significantly higher in the dry cleaning stores using Solvent V, YuClean, and Super New Cleaner than in those using a PERC mixture. Breath concentrations measured prior to and immediately after work were not significantly different for benzene and toluene, whereas breath concentrations of ethylbenzene, m,p-xylene, and o-xylene were significantly higher (p<0.05) in the samples collected immediately after work compared with those collected prior to work. The breath concentrations of benzene and toluene both prior to and immediately after work showed no upward or downward trend for 7 consecutive days excluding Sunday, starting from Monday. In contrast, the breath concentrations of ethylbenzene, m,p-xylene, and o-xylene measured immediately after work showed a slight upward trend in three subjects. However, this trend was most likely not due to an accumulated body burden from repeated daily work, but rather was the result of the amount of solvent used each day. It is concluded that dry cleaning workers using the aromatics-contained solvents are exposed to elevated levels of some aromatic compounds compared with the dry cleaning workers using PERC. Further study is recommended to examine the presence of other air toxics inside dry cleaning stores using these solvents.
- 1 July 2001
- Published by Taylor & Francis in AIHA Journal
- Vol. 62 (4) , 466-471
Worker Exposure to Aromatic Volatile Organic Compounds in Dry Cleaning Stores
This study evaluated worker exposure to aromatic compounds and perchloroethylene (PERC) in dry cleaning stores relative to four different solvents. For benzene and toluene, there was no significant difference among the indoor air concentrations of the four different solvents. For ethylbenzene, m,p-xylene, and o-xylene, the air concentrations were significantly higher in the dry cleaning stores using Solvent V, YuClean, and Super New Cleaner than in those using a PERC mixture. Breath concentrations measured prior to and immediately after work were not significantly different for benzene and toluene, whereas breath concentrations of ethylbenzene, m,p-xylene, and o-xylene were significantly higher (p<0.05) in the samples collected immediately after work compared with those collected prior to work. The breath concentrations of benzene and toluene both prior to and immediately after work showed no upward or downward trend for 7 consecutive days excluding Sunday, starting from Monday. In contrast, the breath concentrations of ethylbenzene, m,p-xylene, and o-xylene measured immediately after work showed a slight upward trend in three subjects. However, this trend was most likely not due to an accumulated body burden from repeated daily work, but rather was the result of the amount of solvent used each day. It is concluded that dry cleaning workers using the aromatics-contained solvents are exposed to elevated levels of some aromatic compounds compared with the dry cleaning workers using PERC. Further study is recommended to examine the presence of other air toxics inside dry cleaning stores using these solvents.
- 1 June 2000
- Published by Elsevier in Environmental Research
- Vol. 83 (2) , 180-187
Utilization of Breath Analysis for Exposure Estimates of Benzene Associated with Active Smoking
- 1 June 2000
- Published by Elsevier in Environmental Research
- Vol. 83 (2) , 180-187
Utilization of Breath Analysis for Exposure Estimates of Benzene Associated with Active Smoking
- Open Access
- 27 December 1999
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 49 (12) , 1425-1433
Characteristics of urban ground-level ozone in Korea.
This study considers the characteristics of ground-level ozone (O3) in five Korean cities over a time period of 6-8 years. The focus of this study is daily maximum 1-hr and 8-hr concentrations. For all the study cities in the period examined, the mean and most of the percentiles (5, 10, 25, 50, 75, 90, and 95) for the daily maximum 1-hr and 8hr concentrations showed increasing trends, although not all trends were statistically significant. The daily maximum 1-hr and 8-hr concentrations slowly increased during late winter, and peaks were attained during the summer season (from May to September). All the selected cities exhibited a high degree of correlation between their daily maximum 8-hr and 1-hr concentrations. The daily maximum 8-hr concentrations, which were climatologi-cally equivalent to the Korean 1 hr/100 parts per billion (ppb) standard, were higher than the current 8 hr/60 ppb by a difference of 8-16 ppb. Compared with other cities in Korea, Seoul recorded a substantially higher frequency of days and hours with concentrations above 1 hr/100 ppb, and a higher frequency of days with concentrations above 8 hr/60 ppb and 8 hr/80 ppb. Seoul also recorded a substantially higher frequency of hours with concentrations above 1 hr/100 ppb than days with concentrations above 1 hr/100 ppb, implying that on some days severe exceedances persisted for more than one hour per day. During multiple-day episodes a North Pacific High dominated Korea, which is quite typical in Korea during the summer season.
- 27 December 1999
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 49 (12) , 1425-1433
Open AccessCharacteristics of urban ground-level ozone in Korea.
This study considers the characteristics of ground-level ozone (O3) in five Korean cities over a time period of 6-8 years. The focus of this study is daily maximum 1-hr and 8-hr concentrations. For all the study cities in the period examined, the mean and most of the percentiles (5, 10, 25, 50, 75, 90, and 95) for the daily maximum 1-hr and 8hr concentrations showed increasing trends, although not all trends were statistically significant. The daily maximum 1-hr and 8-hr concentrations slowly increased during late winter, and peaks were attained during the summer season (from May to September). All the selected cities exhibited a high degree of correlation between their daily maximum 8-hr and 1-hr concentrations. The daily maximum 8-hr concentrations, which were climatologi-cally equivalent to the Korean 1 hr/100 parts per billion (ppb) standard, were higher than the current 8 hr/60 ppb by a difference of 8-16 ppb. Compared with other cities in Korea, Seoul recorded a substantially higher frequency of days and hours with concentrations above 1 hr/100 ppb, and a higher frequency of days with concentrations above 8 hr/60 ppb and 8 hr/80 ppb. Seoul also recorded a substantially higher frequency of hours with concentrations above 1 hr/100 ppb than days with concentrations above 1 hr/100 ppb, implying that on some days severe exceedances persisted for more than one hour per day. During multiple-day episodes a North Pacific High dominated Korea, which is quite typical in Korea during the summer season.
- 31 August 1999
- Published by Elsevier in Atmospheric Environment
- Vol. 33 (18) , 2921-2928
Housewives’ exposure to volatile organic compounds relative to proximity to roadside service stations
- 31 August 1999
- Published by Elsevier in Atmospheric Environment
- Vol. 33 (18) , 2921-2928
Housewives’ exposure to volatile organic compounds relative to proximity to roadside service stations
- 1 June 1999
- Published by Springer Nature in Journal of Exposure Science & Environmental Epidemiology
- Vol. 9 (3) , 217-227
Concentrations of volatile organic compounds in the passenger side and the back seat of automobiles
The in-vehicle volatile organic compound (VOC) concentrations during commutes have previously been measured in only one single interior sampling location, considering a sample collected in the single interior location as representative of overall VOC concentrations within an automobile. The present study evaluated if the potential differences in VOC concentrations occur in the automobiles' interior during idling and commuting under different driving conditions associated with the use of air cleaning devices (ACDs) and interior fan. The experiments were conducted under the low ventilation condition with the windows and the vent closed and the fan off. The difference of VOC concentrations between passenger side and back seat during idling was small. The variability of VOC concentrations with location inside automobiles while commuting was not significant at pppppp-xylene, m-xylene, and o-xylene were 38.3, 107, 9.2, 7.8, 16.9, and 10.7 g/m3, respectively.
- 1 June 1999
- Published by Springer Nature in Journal of Exposure Science & Environmental Epidemiology
- Vol. 9 (3) , 217-227
Concentrations of volatile organic compounds in the passenger side and the back seat of automobiles
The in-vehicle volatile organic compound (VOC) concentrations during commutes have previously been measured in only one single interior sampling location, considering a sample collected in the single interior location as representative of overall VOC concentrations within an automobile. The present study evaluated if the potential differences in VOC concentrations occur in the automobiles' interior during idling and commuting under different driving conditions associated with the use of air cleaning devices (ACDs) and interior fan. The experiments were conducted under the low ventilation condition with the windows and the vent closed and the fan off. The difference of VOC concentrations between passenger side and back seat during idling was small. The variability of VOC concentrations with location inside automobiles while commuting was not significant at pppppp-xylene, m-xylene, and o-xylene were 38.3, 107, 9.2, 7.8, 16.9, and 10.7 g/m3, respectively.
- 1 February 1999
- Published by Elsevier in Atmospheric Environment
- Vol. 33 (3) , 409-417
Commuter exposure to volatile organic compounds under different driving conditions
- 1 February 1999
- Published by Elsevier in Atmospheric Environment
- Vol. 33 (3) , 409-417
Commuter exposure to volatile organic compounds under different driving conditions