    Toxic Anterior Segment Syndrome after Foldable Artiflex Iris-Fixated Phakic Intraocular Lens Implantation

    by Lucien A. M. van Philips

    Toxic anterior segment syndrome (TASS) developed in four cases after uneventful implantation of a foldable iris-fixated phakic intraocular lens (pIOL). Two cases occurred sequentially in one patient. The TASS subsided without complications in all cases after intensive topical steroid treatment. A multitude of possible causes is considered for the occurrence of these TASS cases. From the sterilization and cleaning of surgical instruments to the possibility of endotoxines in ophthalmic viscosurgical devices (OVD). These rare cases should alert the surgeon to the possibility of TASS after pIOL implantation.


  • Higher-order aberrations after iris-fixated foldable phakic intraocular lens implantation and wavefront-guided photorefractive keratectomy for the correction of myopia

    by Lucien A.M. van Philips

    To compare higher-order aberrations (HOAs) after foldable phakic intraocular lens (pIOL) implantation and wavefront-guided photorefractive keratectomy (PRK) for the correction of myopia. Department of Ophthalmology, Medisch Centrum Haaglanden, Den Haag, The Netherlands. Comparative case series. This retrospective comparative case series comprised eyes that had implantation of an Artiflex foldable pIOL or wavefront-guided PRK. Preoperative and postoperative refractive data, pupil diameter, endothelial cell density, and higher-order aberrations (HOAs) were measured and compared. The median follow-up was 13 months in the pIOL group and 10 months in the PRK group. The mean spherical equivalent (SE) in the pIOL group was -5.50 diopters (D) ± 1.05 (SD) (range -3.25 to -7.13 D) preoperatively and -0.26 ± 0.28 D (range -0.88 to 0.38 D) postoperatively and the mean in the PRK group, -5.72 ± 0.88 D (range -4.25 to -7.50 D) and -0.03 ± 0.42 D (range -0.75 to 1.00 D), respectively. The postoperative SE was within ±0.50 D in 86.4% of eyes and 85.2% of eyes, respectively. Postoperatively, the significant changes in the pIOL group and the PRK group, respectively, were as follows: total HOAs, 0.03 μm and 0.26 μm (P = .001); trefoil-y, 0.09 μm and -0.04 μm (P = .004); spherical aberration, -0.05 μm and 0.21 μm (P = .002). Foldable pIOL implantation increased total HOAs and spherical aberration less than wavefront-guided PRK to correct low to moderate myopia, suggesting foldable pIOL implantation maintains the cornea's prolate shape better.


  • High and Low Contrast Visual Acuity After Artiflex Phakic Intraocular Lens Implantation for the Correction of Myopia

    by Lucien A.M. van Philips

    Purpose: To determine the effects of Artiflex phakic intraocular lens (PIOL) implantation on best spectacle-corrected high and low contrast visual acuity under photopic and mesopic conditions. Methods: Forty-two consecutive eyes had implantation of a foldable iris-supported PIOL to correct myopia. The mean preoperative spherical equivalent refraction was −7.26±1.91 diopters (D) (range: −4.90 to −13.60 D). The high (100%) and low (2.5%) contrast visual acuity with best spectacle correction was tested with translucent logarithmic visual acuity charts (Precision Vision) under photopic and mesopic conditions. Results: At mean 7.6±5.4 months after PIOL implantation, the mean high and low contrast visual acuity under photopic and mesopic conditions had significantly increased from preoperatively: photopic high contrast visual acuity from −0.07±0.11 logMAR to −0.14±0.08 logMAR ( P <.001); photopic low contrast visual acuity from 0.48±0.14 logMAR to 0.36±0.11 logMAR ( P =.011); mesopic high contrast visual acuity from −0.09±0.09 logMAR to −0.16±0.08 logMAR ( P <.001); and mesopic low contrast visual acuity from 0.50±0.13 logMAR to 0.33±0.10 logMAR ( P <.001). Mean postoperative spherical equivalent refraction was −0.21±0.28 D (range: +0.50 to −0.75 D). Of all eyes, 91.9% were within 0.50 D of attempted correction, and 67% gained 1 or more lines of best spectacle-corrected visual acuity (BSCVA). No eye lost 2 or more lines of BSCVA. Conclusions: Artiflex PIOL implantation for the correction of moderate to high myopia seems to be a safe and predictable procedure, which resulted in increased high and low contrast visual acuity under photopic and mesopic conditions.