Dirk W. Kiner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dirk W. Kiner has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Christopher D. Wybo
1 shared publication- Clay Alexander Spitler
Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL; and
1 shared publication - Daniel Doty
Department of Orthopaedic Surgery, University of Tennessee Health and Science Center, College of Medicine, Chattanooga, TN, United States
1 shared publication - Josie Hydrick
Department of Orthopedic Surgery, University of Mississippi Medical Center, Jackson, MS, United States
1 shared publication - LaRita C. Jones
Department of Orthopedic Surgery and Rehabilitation, University of Mississippi Medical Center, Jackson, Mississippi
1 shared publication - Peter Nowotarski
Department of Mechanical Engineering, University of Tennessee Chattanooga, College of Engineering & Computer Science, Chattanooga, TN, United States
1 shared publication
Latest Publications
- 1 November 2008
- Published by Wolters Kluwer Health in Spine
- Vol. 33 (24) , 2618-2622
Biomechanical Analysis of Different Techniques in Revision Spinal Instrumentation
Biomechanical analysis. To determine the relative strengths of 2 different forms of revision spinal instrumentation using a validated, constant load, cyclic testing mechanism. Spinal fusion with instrumentation procedures are on the rise. As such, so are revision procedures. A few studies have looked at revision instrumentation techniques. Both increased pedicle screw diameter as well as cement augmentation of pedicle screw fixation have been proposed, used clinically and tested biomechanically. To our knowledge, no comparative study exists between these techniques. Using an instron servohydraulic loading machine, we tested pedicle screws inserted in both the anatomic (angled) and Roy-Camille (straight) insertion technique with both larger diameter (8 mm) pedicle screws, as well as standard diameter (6 mm) pedicle screws augmented with polymethylmethacrylate bone cement. Each of these techniques was subjected to constant load under cyclic conditions for 2000 cycles at 2 Hz. Computerized data collection was used at all time points. Comparisons were made between primary instrumentation data (previously published) and large diameter screws for revision. Further comparisons were made between large diameter screws and cement augmented screws. The larger diameter screws compared with the cement augmented screws showed significant differences in: initial stiffness with straight insertion technique (P < 0.01), stiffness damage with straight insertion technique (P < 0.01), and creep damage with straight insertion technique (P = 0.01). There was also a significant difference between large diameter and primary instrumentation technique all calculated values (P <or= 0.05). The larger diameter screws were equivocal or significantly more resilient than the cement augmented standard diameter screws at the strongest of the insertion angles for all values. Since rigidity of the instrumentation construct is one of the very few factors that is surgeon controlled, this could influence the choice of instrumentation in revision spinal arthrodesis.
- 1 November 2008
- Published by Wolters Kluwer Health in Spine
- Vol. 33 (24) , 2618-2622
Biomechanical Analysis of Different Techniques in Revision Spinal Instrumentation
Biomechanical analysis. To determine the relative strengths of 2 different forms of revision spinal instrumentation using a validated, constant load, cyclic testing mechanism. Spinal fusion with instrumentation procedures are on the rise. As such, so are revision procedures. A few studies have looked at revision instrumentation techniques. Both increased pedicle screw diameter as well as cement augmentation of pedicle screw fixation have been proposed, used clinically and tested biomechanically. To our knowledge, no comparative study exists between these techniques. Using an instron servohydraulic loading machine, we tested pedicle screws inserted in both the anatomic (angled) and Roy-Camille (straight) insertion technique with both larger diameter (8 mm) pedicle screws, as well as standard diameter (6 mm) pedicle screws augmented with polymethylmethacrylate bone cement. Each of these techniques was subjected to constant load under cyclic conditions for 2000 cycles at 2 Hz. Computerized data collection was used at all time points. Comparisons were made between primary instrumentation data (previously published) and large diameter screws for revision. Further comparisons were made between large diameter screws and cement augmented screws. The larger diameter screws compared with the cement augmented screws showed significant differences in: initial stiffness with straight insertion technique (P < 0.01), stiffness damage with straight insertion technique (P < 0.01), and creep damage with straight insertion technique (P = 0.01). There was also a significant difference between large diameter and primary instrumentation technique all calculated values (P <or= 0.05). The larger diameter screws were equivocal or significantly more resilient than the cement augmented standard diameter screws at the strongest of the insertion angles for all values. Since rigidity of the instrumentation construct is one of the very few factors that is surgeon controlled, this could influence the choice of instrumentation in revision spinal arthrodesis.