Hiroyuki Minami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hiroyuki Minami has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Hisanori Kurashige
Senior Instructor, Department of Fixed Prosthodontics, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
3 shared publicationsTakuo Tanaka
Professor, Department of Fixed Prosthodontics, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
3 shared publicationsShiro Suzuki
Visiting Professor, Department of Prosthodontics, University of Alabama at Birmingham, Birmingham, AL
2 shared publicationsYoshito Minesaki
Assistant Professor, Department of Fixed Prosthodontics, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
2 shared publicationsHirohumi Ohashi
1 shared publication- Shiro Suzuki
Visiting Professor, Department of Prosthodontics and Biomaterials, University of Alabama at Birmingham, School of Dentistry, Birmingham, Ala
1 shared publication
Latest Publications
- 11 July 2008
- Published by Wiley in Journal of Prosthodontics
- Vol. 17 (5) , 392-400
In Vitro Evaluation of the Effect of Thermal and Mechanical Fatigues on the Bonding of an Autopolymerizing Soft Denture Liner to Denture Base Materials Using Different Primers
Purpose: This in vitro study evaluated the effect of priming procedures on bonding of an autopolymerizing silicone denture liner (Sofreliner) to a denture base material after fatigue processes using cyclic thermal stressing and repetitive mechanical stressing. Materials and Methods: Denture base specimens were fabricated by use of an autopolymerizing denture base resin and Co–Cr alloy into a cylinder shape 8‐mm diameter and 4‐mm high. The bonding surfaces of denture base specimens were polished with 600‐grit silicon carbide paper. Resin denture base specimens were pretreated with applications of resin primer (Sofreliner Primer or Reline Primer for resin). Metal specimens were pretreated with application of metal primer (Reline Primer for metal) or coated with adhesive resin (C&B Metabond) followed by application of resin primer (Sofreliner Primer). Tensile specimens were fabricated by polymerizing a 2‐mm thickness of Sofreliner between a pair of pretreated denture base cylinders. Repetitive mechanical stressing was performed by using a University of Alabama‐type wear‐testing apparatus as a stress generator. Vertical 75 N load with 15° rotation was applied 66,700, 133,300, 266,700, and 400,000 times, then residual tensile resistance to failure was measured. Seven specimens were fabricated for 16 groups—four cyclic loading groups for four pretreatment groups. Residual tensile resistance to failure of specimens before the fatiguing process and after 5000, 10,000, 20,000, and 30,000 thermocycles were used as reference. The mean values of each group were statistically analyzed by three‐way ANOVA and Bonferroni/Dunn test at a 95% confidence level. Failure modes were assessed for all specimens measured. Results: In the denture‐bonded groups, residual tensile resistance to failure of Sofreliner Primer‐treated group was significantly higher than that of the Reline Primer at each thermocycling interval (p < 0.0001) and up to 133,300 times of cyclic loading (p < 0.0001). In the metal‐bonded groups, residual tensile resistance to failure of the intermediate adhesive resin group was higher than the metal primer‐applied group up to 5000 thermocycles (p < 0.0001); however, there was no significant difference between them after 66,667 cyclic loads (p= 0.1698). Although adhesive resin‐coated specimens of metal‐bonded groups showed mixed failure, metal primer‐applied groups and both denture‐bonded groups consistently revealed cohesive failure of the soft denture liner after cyclic loading. Conclusions: Application of Sofreliner Primer for a resin denture base provided better bonding after thermocycle and cyclic load testing than did Reline Primer. Using an intermediate adhesive resin layer on a Co–Cr denture base material improved the bonding for up to 5000 thermocycles; however, it did not affect cyclic loading parameters.
- 11 July 2008
- Published by Wiley in Journal of Prosthodontics
- Vol. 17 (5) , 392-400
In Vitro Evaluation of the Effect of Thermal and Mechanical Fatigues on the Bonding of an Autopolymerizing Soft Denture Liner to Denture Base Materials Using Different Primers
Purpose: This in vitro study evaluated the effect of priming procedures on bonding of an autopolymerizing silicone denture liner (Sofreliner) to a denture base material after fatigue processes using cyclic thermal stressing and repetitive mechanical stressing. Materials and Methods: Denture base specimens were fabricated by use of an autopolymerizing denture base resin and Co–Cr alloy into a cylinder shape 8‐mm diameter and 4‐mm high. The bonding surfaces of denture base specimens were polished with 600‐grit silicon carbide paper. Resin denture base specimens were pretreated with applications of resin primer (Sofreliner Primer or Reline Primer for resin). Metal specimens were pretreated with application of metal primer (Reline Primer for metal) or coated with adhesive resin (C&B Metabond) followed by application of resin primer (Sofreliner Primer). Tensile specimens were fabricated by polymerizing a 2‐mm thickness of Sofreliner between a pair of pretreated denture base cylinders. Repetitive mechanical stressing was performed by using a University of Alabama‐type wear‐testing apparatus as a stress generator. Vertical 75 N load with 15° rotation was applied 66,700, 133,300, 266,700, and 400,000 times, then residual tensile resistance to failure was measured. Seven specimens were fabricated for 16 groups—four cyclic loading groups for four pretreatment groups. Residual tensile resistance to failure of specimens before the fatiguing process and after 5000, 10,000, 20,000, and 30,000 thermocycles were used as reference. The mean values of each group were statistically analyzed by three‐way ANOVA and Bonferroni/Dunn test at a 95% confidence level. Failure modes were assessed for all specimens measured. Results: In the denture‐bonded groups, residual tensile resistance to failure of Sofreliner Primer‐treated group was significantly higher than that of the Reline Primer at each thermocycling interval (p < 0.0001) and up to 133,300 times of cyclic loading (p < 0.0001). In the metal‐bonded groups, residual tensile resistance to failure of the intermediate adhesive resin group was higher than the metal primer‐applied group up to 5000 thermocycles (p < 0.0001); however, there was no significant difference between them after 66,667 cyclic loads (p= 0.1698). Although adhesive resin‐coated specimens of metal‐bonded groups showed mixed failure, metal primer‐applied groups and both denture‐bonded groups consistently revealed cohesive failure of the soft denture liner after cyclic loading. Conclusions: Application of Sofreliner Primer for a resin denture base provided better bonding after thermocycle and cyclic load testing than did Reline Primer. Using an intermediate adhesive resin layer on a Co–Cr denture base material improved the bonding for up to 5000 thermocycles; however, it did not affect cyclic loading parameters.
- 9 July 2004
- Vol. 17 (3) , 297-301
Effect of surface treatment on the bonding of an autopolymerizing soft denture liner to a denture base resin.
This in vitro study evaluated the effects of surface treatments and thermocycling on the bonding of autopolymerizing silicone soft denture liner (Sofreliner) to denture base resin. The bonding surfaces of denture base cylinders were polished with 600-grit silicon carbide paper and pretreated with applications of Sofreliner Primer, Sofreliner Primer after air abrasion, Reline Primer, or Reline Primer after air abrasion. Failure loads and elongation at failure were measured after subjecting specimens to 0, 10,000, 20,000, and 30,000 thermocycles. Failure modes were assessed for all specimens. Seven specimens were fabricated for each of 16 groups, including four pretreatments and four thermocycle groups. Failure loads of the Sofreliner Primer group were significantly higher than those of the air-abrasion group up to 20,000 thermocycles; both groups showed cohesive failures of the soft denture liner. Failure loads of the Reline Primer group were significantly higher than with Reline Primer after air abrasion up to 10,000 thermocycles. Failure mode after 10,000 thermocycles was cohesive for the Reline Primer group and mixed cohesive/adhesive for Reline Primer after air abrasion. Failure loads of the Sofreliner Primer group were significantly higher than those of the Reline Primer group at each thermocycling interval. Elongation values decreased after 10,000 thermocycles for all groups. Air abrasion on the denture base resin surface was not effective in enhancing failure load. Cyclic thermal stress is one factor degrading the bond between soft denture liner and acrylic resin denture base.
- 9 July 2004
- Vol. 17 (3) , 297-301
Effect of surface treatment on the bonding of an autopolymerizing soft denture liner to a denture base resin.
This in vitro study evaluated the effects of surface treatments and thermocycling on the bonding of autopolymerizing silicone soft denture liner (Sofreliner) to denture base resin. The bonding surfaces of denture base cylinders were polished with 600-grit silicon carbide paper and pretreated with applications of Sofreliner Primer, Sofreliner Primer after air abrasion, Reline Primer, or Reline Primer after air abrasion. Failure loads and elongation at failure were measured after subjecting specimens to 0, 10,000, 20,000, and 30,000 thermocycles. Failure modes were assessed for all specimens. Seven specimens were fabricated for each of 16 groups, including four pretreatments and four thermocycle groups. Failure loads of the Sofreliner Primer group were significantly higher than those of the air-abrasion group up to 20,000 thermocycles; both groups showed cohesive failures of the soft denture liner. Failure loads of the Reline Primer group were significantly higher than with Reline Primer after air abrasion up to 10,000 thermocycles. Failure mode after 10,000 thermocycles was cohesive for the Reline Primer group and mixed cohesive/adhesive for Reline Primer after air abrasion. Failure loads of the Sofreliner Primer group were significantly higher than those of the Reline Primer group at each thermocycling interval. Elongation values decreased after 10,000 thermocycles for all groups. Air abrasion on the denture base resin surface was not effective in enhancing failure load. Cyclic thermal stress is one factor degrading the bond between soft denture liner and acrylic resin denture base.
- 1 February 2004
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 91 (2) , 164-170
In vitro evaluation of the influence of repairing condition of denture base resin on the bonding of autopolymerizing resins
- 1 February 2004
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 91 (2) , 164-170
In vitro evaluation of the influence of repairing condition of denture base resin on the bonding of autopolymerizing resins