Joseph Stancanello
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joseph Stancanello has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Giancarlo Ferrigno
Politecnico di Milano
4 shared publications - Nicola Modugno
IRCCS Neuromed, Pozzilli (IS), Italy
3 shared publications - Pietro Cerveri
Università di Pavia, Via A. Ferrata, 5, Pave, 27100, Italy
3 shared publications - Carlo Cavedon
Medical Physics Unit, Azienda Ospedaliera Universitaria Integrata, Verona, Italy
2 shared publications F. Uggeri
Imaging Laboratory; Bracco Imaging; Colleretto Giacosa, TO, Italy
2 shared publicationsFulvio Uggeri
2 shared publications
Latest Publications
- 1 December 2015
- Published by Elsevier in Physica Medica
- Vol. 31 (8) , 1022-1028
Hypofractionation of partial breast irradiation using radiobiological models
- 1 December 2015
- Published by Elsevier in Physica Medica
- Vol. 31 (8) , 1022-1028
Hypofractionation of partial breast irradiation using radiobiological models
- Open Access
- 20 July 2011
- Published by Cureus, Inc. in Cureus
- Vol. 3 (7)
Excellent image quality or superior dose conformity?
- 20 July 2011
- Published by Cureus, Inc. in Cureus
- Vol. 3 (7)
Open AccessExcellent image quality or superior dose conformity?
- Open Access
- 30 November 2010
- Published by Cureus, Inc. in Cureus
- Vol. 2 (11)
What if you cannot see the target? Two case studies of atlas-to-patient registration in trigeminal neuralgia radiosurgery.
Introduction: Medically resistant trigeminal neuralgia (TN) is a well-suited pathology to be treated by radiosurgery (RS). A significant percentage (60%-70%) of patients is expected to benefit from the RS treatment. Imaging is crucial to identify the target, though unfortunately in some cases the trigeminal nerve could not be visible even in high field magnetic resonance images (MRI). The aim of this work is to develop and relatively validate a method for the atlas-based identification of the target in those cases where the trigeminal nerve is not visible. Material Methods: The proposed method is based on the modification of a previously published approach for functional RS, adapted to the TN. A high resolution, high contrast volumetric T1-MRI atlas was non-rigidly registered to patient T1-MRI. Two patients scanned with a 3T T1-weighted-MRI and trigeminal nerve specific MR (Constructive Interference in Steady State – CISS) sequences were considered in this study. In both cases, the right-sided trigeminal nerve was not visible, while it was the contralateral nerve. For one patient, we simulated a potential radiosurgical treatment plan. The atlas-based localization accuracy of the trigeminal nerve was validated in a relative way evaluating the nearby structure continuity and the contralateral nerve localization. Results: The atlas-based fusion showed a high degree of relative accuracy in both cases, suggesting a not ideal coverage of the trigeminal nerve in the simulated treatment plan while opening the way to a possible treatment for both patients. Conclusions: The proposed method holds potential to support the physician to correctly locate the target in those cases where trigeminal nerve is not visible for RS, as well as other therapeutic image-guided applications. Additional cases and further validation in absolute way are needed to definitively assess the accuracy of the method.
- 30 November 2010
- Published by Cureus, Inc. in Cureus
- Vol. 2 (11)
Open AccessWhat if you cannot see the target? Two case studies of atlas-to-patient registration in trigeminal neuralgia radiosurgery.
Introduction: Medically resistant trigeminal neuralgia (TN) is a well-suited pathology to be treated by radiosurgery (RS). A significant percentage (60%-70%) of patients is expected to benefit from the RS treatment. Imaging is crucial to identify the target, though unfortunately in some cases the trigeminal nerve could not be visible even in high field magnetic resonance images (MRI). The aim of this work is to develop and relatively validate a method for the atlas-based identification of the target in those cases where the trigeminal nerve is not visible. Material Methods: The proposed method is based on the modification of a previously published approach for functional RS, adapted to the TN. A high resolution, high contrast volumetric T1-MRI atlas was non-rigidly registered to patient T1-MRI. Two patients scanned with a 3T T1-weighted-MRI and trigeminal nerve specific MR (Constructive Interference in Steady State – CISS) sequences were considered in this study. In both cases, the right-sided trigeminal nerve was not visible, while it was the contralateral nerve. For one patient, we simulated a potential radiosurgical treatment plan. The atlas-based localization accuracy of the trigeminal nerve was validated in a relative way evaluating the nearby structure continuity and the contralateral nerve localization. Results: The atlas-based fusion showed a high degree of relative accuracy in both cases, suggesting a not ideal coverage of the trigeminal nerve in the simulated treatment plan while opening the way to a possible treatment for both patients. Conclusions: The proposed method holds potential to support the physician to correctly locate the target in those cases where trigeminal nerve is not visible for RS, as well as other therapeutic image-guided applications. Additional cases and further validation in absolute way are needed to definitively assess the accuracy of the method.
- 5 January 2010
- Published by Wiley in Medical Physics
- Vol. 37 (2) , 409-411
The traditional L-shaped gantry for radiotherapy linear accelerators will soon become obsolete
- 5 January 2010
- Published by Wiley in Medical Physics
- Vol. 37 (2) , 409-411
The traditional L-shaped gantry for radiotherapy linear accelerators will soon become obsolete
- 14 January 2009
- Published by Wiley in Medical Physics
- Vol. 36 (2) , 457-463
Atlas‐based functional radiosurgery: Early results
Functional disorders of the brain, such as dystonia and neuropathic pain, may respond poorly to medical therapy. Deep brain stimulation (DBS) of the globus pallidus pars interna (GPi) and the centromedian nucleus of the thalamus (CMN) may alleviate dystonia and neuropathic pain, respectively. A noninvasive alternative to DBS is radiosurgical ablation [internal pallidotomy (IP) and medial thalamotomy (MT)]. The main technical limitation of radiosurgery is that targets are selected only on the basis of MRI anatomy, without electrophysiological confirmation. This means that, to be feasible, image-based targeting must be highly accurate and reproducible. Here, we report on the feasibility of an atlas-based approach to targeting for functional radiosurgery. In this method, masks of the GPi, CMN, and medio-dorsal nucleus were nonrigidly registered to patients' T1-weighted MRI (T1w-MRI) and superimposed on patients' T2-weighted MRI (T2w-MRI). Radiosurgical targets were identified on the T2w-MRI registered to the planning CT by an expert functional neurosurgeon. To assess its feasibility, two patients were treated with the CyberKnife using this method of targeting; a patient with dystonia received an IP (120 Gy prescribed to the 65% isodose) and a patient with neuropathic pain received a MT (120 Gy to the 77% isodose). Six months after treatment, T2w-MRIs and contrast-enhanced T1w-MRIs showed edematous regions around the lesions; target placements were reevaluated by DW-MRIs. At 12 months post-treatment steroids for radiation-induced edema and medications for dystonia and neuropathic pain were suppressed. Both patients experienced significant relief from pain and dystonia-related problems. Fifteen months after treatment edema had disappeared. Thus, this work shows promising feasibility of atlas-based functional radiosurgery to improve patient condition. Further investigations are indicated for optimizing treatment dose.
- 14 January 2009
- Published by Wiley in Medical Physics
- Vol. 36 (2) , 457-463
Atlas‐based functional radiosurgery: Early results
Functional disorders of the brain, such as dystonia and neuropathic pain, may respond poorly to medical therapy. Deep brain stimulation (DBS) of the globus pallidus pars interna (GPi) and the centromedian nucleus of the thalamus (CMN) may alleviate dystonia and neuropathic pain, respectively. A noninvasive alternative to DBS is radiosurgical ablation [internal pallidotomy (IP) and medial thalamotomy (MT)]. The main technical limitation of radiosurgery is that targets are selected only on the basis of MRI anatomy, without electrophysiological confirmation. This means that, to be feasible, image-based targeting must be highly accurate and reproducible. Here, we report on the feasibility of an atlas-based approach to targeting for functional radiosurgery. In this method, masks of the GPi, CMN, and medio-dorsal nucleus were nonrigidly registered to patients' T1-weighted MRI (T1w-MRI) and superimposed on patients' T2-weighted MRI (T2w-MRI). Radiosurgical targets were identified on the T2w-MRI registered to the planning CT by an expert functional neurosurgeon. To assess its feasibility, two patients were treated with the CyberKnife using this method of targeting; a patient with dystonia received an IP (120 Gy prescribed to the 65% isodose) and a patient with neuropathic pain received a MT (120 Gy to the 77% isodose). Six months after treatment, T2w-MRIs and contrast-enhanced T1w-MRIs showed edematous regions around the lesions; target placements were reevaluated by DW-MRIs. At 12 months post-treatment steroids for radiation-induced edema and medications for dystonia and neuropathic pain were suppressed. Both patients experienced significant relief from pain and dystonia-related problems. Fifteen months after treatment edema had disappeared. Thus, this work shows promising feasibility of atlas-based functional radiosurgery to improve patient condition. Further investigations are indicated for optimizing treatment dose.
- 1 July 2008
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 3 (4) , 136-149
Development and validation of a smoothing‐splines‐based correction method for improving the analysis of CEST‐MR images
Chemical exchange saturation transfer (CEST) imaging is an emerging MRI technique relying on the use of endogenous or exogenous molecules containing exchangeable proton pools. The heterogeneity of the water resonance frequency offset plays a key role in the occurrence of artifacts in CEST‐MR images. To limit this drawback, a new smoothing‐splines‐based method for fitting and correcting Z‐spectra in order to compensate for low signal‐to‐noise ratio (SNR) without any a priori model was developed. Global and local voxel‐by‐voxel Z‐spectra were interpolated by smoothing splines with smoothing terms aimed at suppressing noise. Thus, a map of the water frequency offset (‘zero’ map) was used to correctly calculate the saturation transfer (ST) for each voxel. Simulations were performed to compare the method to polynomials and zero‐only‐corrected splines on the basis of SNR improvement. In vitro acquisitions of capillaries containing solutions of LIPOCEST agents at different concentrations were performed to experimentally validate the results from simulations. Additionally, ex vivo investigations of bovine muscle mass injected with LIPOCEST agents were performed as a function of increasing pulse power. The results from simulations and experiments highlighted the importance of a proper ‘zero’ correction (15% decrease of fictitious CEST signal in phantoms and ex vivo preparations) and proved the method to be more accurate compared with the previously published ones, often providing a SNR higher than 5 in different simulated and experimentally noisy conditions. In conclusion, the proposed method offers an accurate tool in CEST investigation. Copyright © 2008 John Wiley & Sons, Ltd.
- 1 July 2008
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 3 (4) , 136-149
Development and validation of a smoothing‐splines‐based correction method for improving the analysis of CEST‐MR images
Chemical exchange saturation transfer (CEST) imaging is an emerging MRI technique relying on the use of endogenous or exogenous molecules containing exchangeable proton pools. The heterogeneity of the water resonance frequency offset plays a key role in the occurrence of artifacts in CEST‐MR images. To limit this drawback, a new smoothing‐splines‐based method for fitting and correcting Z‐spectra in order to compensate for low signal‐to‐noise ratio (SNR) without any a priori model was developed. Global and local voxel‐by‐voxel Z‐spectra were interpolated by smoothing splines with smoothing terms aimed at suppressing noise. Thus, a map of the water frequency offset (‘zero’ map) was used to correctly calculate the saturation transfer (ST) for each voxel. Simulations were performed to compare the method to polynomials and zero‐only‐corrected splines on the basis of SNR improvement. In vitro acquisitions of capillaries containing solutions of LIPOCEST agents at different concentrations were performed to experimentally validate the results from simulations. Additionally, ex vivo investigations of bovine muscle mass injected with LIPOCEST agents were performed as a function of increasing pulse power. The results from simulations and experiments highlighted the importance of a proper ‘zero’ correction (15% decrease of fictitious CEST signal in phantoms and ex vivo preparations) and proved the method to be more accurate compared with the previously published ones, often providing a SNR higher than 5 in different simulated and experimentally noisy conditions. In conclusion, the proposed method offers an accurate tool in CEST investigation. Copyright © 2008 John Wiley & Sons, Ltd.
- 12 June 2008
- Published by Wiley in Medical Physics
- Vol. 35 (7Part1) , 3069-3077
3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification
Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial border of the STN often blends with the substantia nigra. 3 T magnetic resonance imaging (MRI) provides better resolution and can improve the identification of the STN borders. In this work, we have directly identified the STN using 3 T MR imaging to validate the accuracy of a computer-aided atlas-based procedure for automatic STN identification. Coordinates of the STN were obtained from the Talairach and Tournoux atlas and transformed into the coordinates of the Montreal Neurological Institute (MNI) standard brain volume, creating a mask representation of the STN. 3 T volumetric T1 and T2 weighted (T1w and T2w, respectively) acquisitions were obtained for ten patients. The MNI standard brain volume was registered onto each patient MRI, using a new approach based on global affine, region-of-interest affine, and local nonrigid registrations. The estimated deformation field was then applied to the STN atlas-based mask, providing its location on the patient MRI. The entire procedure required on average about 20 min. Because STN is easily identifiable on 3 T T2w-MRIs, it was manually delineated; the coordinates of the center of mass of the manually and automatically identified structures were compared. Additionally, volumetric overlapping indices were calculated and the spatial relationship between the midcommissural point and the STN center of mass was investigated. All indices indicated, on average, good agreement between manually and automatically identified structures; displacement of the centers of mass of the manually and automatically identified structures was less than or equal to 2.35 mm, and more than 80% of the manually identified volume was covered by the automatic localization, on average. Bland-Altman analysis indicated that the automatic STN identification was within the limits of agreement with the manual localization on 3 T MRIs. Automatic atlas-based STN localization provides an accurate and user-friendly tool and can enhance target identification when 1.5 T scanners with limited capability to identify the STN boundaries are used.
- 12 June 2008
- Published by Wiley in Medical Physics
- Vol. 35 (7Part1) , 3069-3077
3T MRI evaluation of the accuracy of atlas-based subthalamic nucleus identification
Modulation of the activity of the subthalamic nucleus (STN) using deep brain stimulation (DBS) in patients with advanced Parkinson's disease is the most common procedure performed today by functional neurosurgeons. The STN contours cannot be entirely identified on common 1.5 T images; in particular, the ventromedial border of the STN often blends with the substantia nigra. 3 T magnetic resonance imaging (MRI) provides better resolution and can improve the identification of the STN borders. In this work, we have directly identified the STN using 3 T MR imaging to validate the accuracy of a computer-aided atlas-based procedure for automatic STN identification. Coordinates of the STN were obtained from the Talairach and Tournoux atlas and transformed into the coordinates of the Montreal Neurological Institute (MNI) standard brain volume, creating a mask representation of the STN. 3 T volumetric T1 and T2 weighted (T1w and T2w, respectively) acquisitions were obtained for ten patients. The MNI standard brain volume was registered onto each patient MRI, using a new approach based on global affine, region-of-interest affine, and local nonrigid registrations. The estimated deformation field was then applied to the STN atlas-based mask, providing its location on the patient MRI. The entire procedure required on average about 20 min. Because STN is easily identifiable on 3 T T2w-MRIs, it was manually delineated; the coordinates of the center of mass of the manually and automatically identified structures were compared. Additionally, volumetric overlapping indices were calculated and the spatial relationship between the midcommissural point and the STN center of mass was investigated. All indices indicated, on average, good agreement between manually and automatically identified structures; displacement of the centers of mass of the manually and automatically identified structures was less than or equal to 2.35 mm, and more than 80% of the manually identified volume was covered by the automatic localization, on average. Bland-Altman analysis indicated that the automatic STN identification was within the limits of agreement with the manual localization on 3 T MRIs. Automatic atlas-based STN localization provides an accurate and user-friendly tool and can enhance target identification when 1.5 T scanners with limited capability to identify the STN boundaries are used.
- 13 March 2007
- Published by Wiley in Medical Physics
- Vol. 34 (4) , 1176-1184
BOLD FMRI integration into radiosurgery treatment planning of cerebral vascular malformations
Functional magnetic resonance imaging (fMRI) is used to distinguish areas of the brain responsible for different tasks and functions. It is possible, for example, by using fMRI images, to identify particular regions in the brain which can be considered as “functional organs at risk” (fOARs), i.e., regions which would cause significant patient morbidity if compromised. The aim of this study is to propose and validate a method to exploit functional information for the identification of fOARs in CyberKnife (Accuray, Inc., Sunnyvale, CA) radiosurgery treatment planning; in particular, given the high spatial accuracy offered by the CyberKnife system, local nonrigid registration is used to reach accurate image matching. Five patients affected by arteriovenous malformations (AVMs) and scheduled to undergo radiosurgery were scanned prior to treatment using computed tomography (CT), three‐dimensional (3D) rotational angiography (3DRA), T2 weighted and blood oxygenation level dependent echo planar imaging MRI. Tasks were chosen on the basis of lesion location by considering those areas which could be potentially close to treatment targets. Functional data were superimposed on 3DRA and CT used for treatment planning. The procedure for the localization of fMRI areas was validated by direct cortical stimulation on and tumor patients undergoing conventional surgery. Treatment plans studied with and without considering fOARs were significantly different, in particular with respect to both maximum dose and dose volume histograms; consideration of the fOARs allowed quality indices of treatment plans to remain almost constant or to improve in four out of five cases compared to plans with no consideration of fOARs. In conclusion, the presented method provides an accurate tool for the integration of functional information into AVM radiosurgery, which might help to minimize undesirable side effects and to make radiosurgery less invasive.
- 13 March 2007
- Published by Wiley in Medical Physics
- Vol. 34 (4) , 1176-1184
BOLD FMRI integration into radiosurgery treatment planning of cerebral vascular malformations
Functional magnetic resonance imaging (fMRI) is used to distinguish areas of the brain responsible for different tasks and functions. It is possible, for example, by using fMRI images, to identify particular regions in the brain which can be considered as “functional organs at risk” (fOARs), i.e., regions which would cause significant patient morbidity if compromised. The aim of this study is to propose and validate a method to exploit functional information for the identification of fOARs in CyberKnife (Accuray, Inc., Sunnyvale, CA) radiosurgery treatment planning; in particular, given the high spatial accuracy offered by the CyberKnife system, local nonrigid registration is used to reach accurate image matching. Five patients affected by arteriovenous malformations (AVMs) and scheduled to undergo radiosurgery were scanned prior to treatment using computed tomography (CT), three‐dimensional (3D) rotational angiography (3DRA), T2 weighted and blood oxygenation level dependent echo planar imaging MRI. Tasks were chosen on the basis of lesion location by considering those areas which could be potentially close to treatment targets. Functional data were superimposed on 3DRA and CT used for treatment planning. The procedure for the localization of fMRI areas was validated by direct cortical stimulation on and tumor patients undergoing conventional surgery. Treatment plans studied with and without considering fOARs were significantly different, in particular with respect to both maximum dose and dose volume histograms; consideration of the fOARs allowed quality indices of treatment plans to remain almost constant or to improve in four out of five cases compared to plans with no consideration of fOARs. In conclusion, the presented method provides an accurate tool for the integration of functional information into AVM radiosurgery, which might help to minimize undesirable side effects and to make radiosurgery less invasive.
- 1 January 2007
- Published by Springer Nature in IFMBE Proceedings
- p. 3126-3129
Atlas Based Identification of Targets for Functional Radiosurgery
- 1 January 2007
- Published by Springer Nature in IFMBE Proceedings
- p. 3126-3129
Atlas Based Identification of Targets for Functional Radiosurgery
- 20 May 2004
- Published by Wiley in Medical Physics
- Vol. 31 (6) , 1363-1371
Development and validation of a CT‐3D rotational angiography registration method for AVM radiosurgery
In this paper a novel technique is proposed and validated for radiosurgery treatment planning of arteriovenous malformations (AVMs). The technique was developed for frameless radiosurgery by means of the CyberKnife, a nonisocentric, linac-based system which allows highly conformed isodose surfaces to be obtained, while also being valid for other treatment strategies. The technique is based on registration between computed tomography (CT) and three-dimensional rotational angiography (3DRA). Tests were initially performed on the effectiveness of the correction method for distortion offered by the angiographic system. These results determined the registration technique that was ultimately chosen. For CT-3DRA registration, a twelve-parameter affine transformation was selected, based on a mutual information maximization algorithm. The robustness of the algorithm was tested by attempting to register data sets increasingly distant from each other, both in translation and rotation. Registration accuracy was estimated by means of the "full circle consistency test." A registration quality index (expressed in millimeters) based on these results was also defined. A hybrid subtraction between CT and 3DRA is proposed in order to improve 3D reconstruction. Preprocessing improved the ability of the algorithm to find an acceptable solution to the registration process. The robustness tests showed that data sets must be manually prealigned within approximately 15 mm and 20 degrees with respect to all three directions simultaneously. Results of the consistency test showed agreement between the quality index and registration accuracy stated by visual inspection in 20 good and 10 artificially worsened registration processes. The quality index showed values smaller than the maximum voxel size (mean 0.8 mm compared to 2 mm) for all successful registrations, while it resulted in much greater values (mean 20 mm) for unsuccessful registrations. Once registered, the two data sets can be used for CyberKnife treatment planning. Target delineation is performed on 3DRA while dose calculation and DRR generation are performed on CT. In conclusion, a method was developed for using 3DRA images for AVM frameless radiosurgery treatment planning. The method proved to be feasible, robust, and accurate for clinical use. 3DRA can be performed at different times or locations compared to standard, frame based stereotactic angiography. Unlike two-dimensional angiography, 3DRA allows examination of the shape of the AVM and of the surrounding target from any arbitrary point of view during treatment planning. The method can be applied to any case of intermodality registration, is operator-independent, and allows estimation of registration quality. Further research is desirable to improve time resolution in order to distinguish between feeding and draining vessels.
- 20 May 2004
- Published by Wiley in Medical Physics
- Vol. 31 (6) , 1363-1371
Development and validation of a CT‐3D rotational angiography registration method for AVM radiosurgery
In this paper a novel technique is proposed and validated for radiosurgery treatment planning of arteriovenous malformations (AVMs). The technique was developed for frameless radiosurgery by means of the CyberKnife, a nonisocentric, linac-based system which allows highly conformed isodose surfaces to be obtained, while also being valid for other treatment strategies. The technique is based on registration between computed tomography (CT) and three-dimensional rotational angiography (3DRA). Tests were initially performed on the effectiveness of the correction method for distortion offered by the angiographic system. These results determined the registration technique that was ultimately chosen. For CT-3DRA registration, a twelve-parameter affine transformation was selected, based on a mutual information maximization algorithm. The robustness of the algorithm was tested by attempting to register data sets increasingly distant from each other, both in translation and rotation. Registration accuracy was estimated by means of the "full circle consistency test." A registration quality index (expressed in millimeters) based on these results was also defined. A hybrid subtraction between CT and 3DRA is proposed in order to improve 3D reconstruction. Preprocessing improved the ability of the algorithm to find an acceptable solution to the registration process. The robustness tests showed that data sets must be manually prealigned within approximately 15 mm and 20 degrees with respect to all three directions simultaneously. Results of the consistency test showed agreement between the quality index and registration accuracy stated by visual inspection in 20 good and 10 artificially worsened registration processes. The quality index showed values smaller than the maximum voxel size (mean 0.8 mm compared to 2 mm) for all successful registrations, while it resulted in much greater values (mean 20 mm) for unsuccessful registrations. Once registered, the two data sets can be used for CyberKnife treatment planning. Target delineation is performed on 3DRA while dose calculation and DRR generation are performed on CT. In conclusion, a method was developed for using 3DRA images for AVM frameless radiosurgery treatment planning. The method proved to be feasible, robust, and accurate for clinical use. 3DRA can be performed at different times or locations compared to standard, frame based stereotactic angiography. Unlike two-dimensional angiography, 3DRA allows examination of the shape of the AVM and of the surrounding target from any arbitrary point of view during treatment planning. The method can be applied to any case of intermodality registration, is operator-independent, and allows estimation of registration quality. Further research is desirable to improve time resolution in order to distinguish between feeding and draining vessels.