F. Chazarenc
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
F. Chazarenc has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jacques Brisson
Université de Montréal
2 shared publications - Yves Comeau
Department of Civil, Geological and Mining Engineering, Polytechnique Montreal, Montreal, H3C 3A7, Quebec, Canada
2 shared publications G. Maltais-Landry
Institut de Recherche en Biologie Végétale, Université de Montréal 4101, rue Sherbrooke Est, Montréal, (Québec) Canada H1X 2B2
1 shared publication- Gerard Merlin
Laboratoire Optimisation de la Conception et Ingénierie de l'Environnement, Université de Savoie, Campus Scientifique, 73 376 Le Bourget du Lac Cedex, France
1 shared publication S. Troesch
Institut de Recherche en Biologie Végétale, Université de Montréal 4101, rue Sherbrooke Est, Montréal, (Québec) Canada H1X 2B2
1 shared publication
Latest Publications
- 1 August 2007
- Published by IWA Publishing in Water Science & Technology
- Vol. 56 (3) , 23-29
Effect of loading rate on performance of constructed wetlands treating an anaerobic supernatant
The effect of organic loading, season and plant species on the treatment of fish farm effluent was tested using three-year old mesocosm wetland systems. During one year, nine 1 m2 mesocosms (horizontal subsurface flow), located in a controlled greenhouse environment, were fed with a reconstituted fish farm effluent containing a high fraction of soluble components (1,600 μS/cm and in mg/L: 230±80 COD, 179±60 sCOD, 100±40 TSS, 37±7 TKN, 14±2 TP). Combinations of three hydraulic loading rates (30, 60 and 90 L.m−2 d−1) and two plant species (Phragmites australis, Typha angustifolia) and an unplanted control were tested for treatment performance and hydraulic behaviour. Loadings higher than 15 g COD m−2 d−1 resulted in a net decrease of hydraulic performances (generation of short circuiting) coupled with low TKN removal. Maximal TKN removal rates (summer: 1.2, winter: 0.6 g.m−2 d−1) were reached in planted units. In all mesocosms, phosphorus was removed during summer (maximal removal rate: 0.3 g TP m−2 d−1) and was released in winter (release rate= ∼ half of summer removal rate). This study confirmed that constructed wetlands are susceptible to clogging when treating anaerobic storage tank supernatant rich in highly biodegradable compounds. Contributions of plants to hydraulic efficiency were mainly observed in summer, associated with high evapotranspiration rates. Both plant species gave a similar removal efficiency for all pollutants.
- 1 August 2007
- Published by IWA Publishing in Water Science & Technology
- Vol. 56 (3) , 23-29
Effect of loading rate on performance of constructed wetlands treating an anaerobic supernatant
The effect of organic loading, season and plant species on the treatment of fish farm effluent was tested using three-year old mesocosm wetland systems. During one year, nine 1 m2 mesocosms (horizontal subsurface flow), located in a controlled greenhouse environment, were fed with a reconstituted fish farm effluent containing a high fraction of soluble components (1,600 μS/cm and in mg/L: 230±80 COD, 179±60 sCOD, 100±40 TSS, 37±7 TKN, 14±2 TP). Combinations of three hydraulic loading rates (30, 60 and 90 L.m−2 d−1) and two plant species (Phragmites australis, Typha angustifolia) and an unplanted control were tested for treatment performance and hydraulic behaviour. Loadings higher than 15 g COD m−2 d−1 resulted in a net decrease of hydraulic performances (generation of short circuiting) coupled with low TKN removal. Maximal TKN removal rates (summer: 1.2, winter: 0.6 g.m−2 d−1) were reached in planted units. In all mesocosms, phosphorus was removed during summer (maximal removal rate: 0.3 g TP m−2 d−1) and was released in winter (release rate= ∼ half of summer removal rate). This study confirmed that constructed wetlands are susceptible to clogging when treating anaerobic storage tank supernatant rich in highly biodegradable compounds. Contributions of plants to hydraulic efficiency were mainly observed in summer, associated with high evapotranspiration rates. Both plant species gave a similar removal efficiency for all pollutants.
- 1 August 2007
- Published by IWA Publishing in Water Science & Technology
- Vol. 56 (3) , 109-115
Slag columns for upgrading phosphorus removal from constructed wetland effluents
The current best option to upgrade constructed wetlands (CWs) for phosphorus (P) retention, in terms of efficiency, cost and simplicity, consists in using media having a strong P affinity. The media can be used either in the planted beds or in a filtration system downstream of the beds. The use of slag filters was shown to be efficient for removing P from wastewater as it represented a slow release source of calcium and hydroxide, favouring the formation of hydroxyapatite. Our study aimed at maximising the P retention capacity of slag filters located at the outlet of CWs since electric arc furnace slag has been shown to inhibit the growth of macrophytes when used in the filtration matrix. Bench-scale columns (Vtot = 6.2 L) filled with various combinations of filter media (slag, granite, limestone) of different sizes (2–5, 5–10, 10–20 mm) were fed on-site during four months with a CW effluent (in mg/L: 30 COD, 30 TSS, 10 Pt). Results showed that the best media combination enabling the maximum o-PO4 retention (more than 80% removal without clogging) consisted in a series of a ternary mix column (slag 5–10 mm, granite 2–5 mm, limestone 5–10 mm) followed by a slag column (slag 5–10 mm). Pilot scale columns (Vtot = 300 L), filled with the best media combination, were installed at the outlet of a 28 m2 CW. These columns showed more than 75% removal efficiency during one year and were designed to be easily replaced each year.
- 1 August 2007
- Published by IWA Publishing in Water Science & Technology
- Vol. 56 (3) , 109-115
Slag columns for upgrading phosphorus removal from constructed wetland effluents
The current best option to upgrade constructed wetlands (CWs) for phosphorus (P) retention, in terms of efficiency, cost and simplicity, consists in using media having a strong P affinity. The media can be used either in the planted beds or in a filtration system downstream of the beds. The use of slag filters was shown to be efficient for removing P from wastewater as it represented a slow release source of calcium and hydroxide, favouring the formation of hydroxyapatite. Our study aimed at maximising the P retention capacity of slag filters located at the outlet of CWs since electric arc furnace slag has been shown to inhibit the growth of macrophytes when used in the filtration matrix. Bench-scale columns (Vtot = 6.2 L) filled with various combinations of filter media (slag, granite, limestone) of different sizes (2–5, 5–10, 10–20 mm) were fed on-site during four months with a CW effluent (in mg/L: 30 COD, 30 TSS, 10 Pt). Results showed that the best media combination enabling the maximum o-PO4 retention (more than 80% removal without clogging) consisted in a series of a ternary mix column (slag 5–10 mm, granite 2–5 mm, limestone 5–10 mm) followed by a slag column (slag 5–10 mm). Pilot scale columns (Vtot = 300 L), filled with the best media combination, were installed at the outlet of a 28 m2 CW. These columns showed more than 75% removal efficiency during one year and were designed to be easily replaced each year.
- 1 May 2005
- Published by IWA Publishing in Water Science & Technology
- Vol. 51 (9) , 91-97
Influence of surface layer on hydrology and biology of gravel bed vertical flow constructed wetlands
In France, gravel vertical flow constructed wetlands (gVFCWs) were adapted to treat raw wastewater, which led to important accumulations of matter in filters (organic and mineral). To prevent clogging, large gravel sizes were employed (∅ 2–6 mm). The aim of this paper was to present the influences of matter accumulation on the hydraulic and biological behaviour of the system. A one-year survey of accumulated matter content and potential respiration activities was completed in three gVFCWs (operating for 3, 4 and 8 years). Cores were sampled into filters. Results showed a vertical stratification of accumulated matter and respiration rates. Dry accumulated matter quantities ranged from 20 kg m−2 (3 and 4 years operating) to 80 kg m−2 in the oldest plant (8 years). Potential respiration was larger in the oldest plant (75 g O2 m−2 h−1) than in the most recent one (15 g O2 m−2 h−1). Accumulated matter seemed to play a role both on the water retention (enhancing initial percolation time by 5 times) and biological profile (enhancing microfauna's diversity). Contrary to what is generally proposed in the literature, accumulated matter in French gVFCWs seemed to provide better treatment efficiency without leading to surface clogging compared to systems using sand.
- 1 May 2005
- Published by IWA Publishing in Water Science & Technology
- Vol. 51 (9) , 91-97
Influence of surface layer on hydrology and biology of gravel bed vertical flow constructed wetlands
In France, gravel vertical flow constructed wetlands (gVFCWs) were adapted to treat raw wastewater, which led to important accumulations of matter in filters (organic and mineral). To prevent clogging, large gravel sizes were employed (∅ 2–6 mm). The aim of this paper was to present the influences of matter accumulation on the hydraulic and biological behaviour of the system. A one-year survey of accumulated matter content and potential respiration activities was completed in three gVFCWs (operating for 3, 4 and 8 years). Cores were sampled into filters. Results showed a vertical stratification of accumulated matter and respiration rates. Dry accumulated matter quantities ranged from 20 kg m−2 (3 and 4 years operating) to 80 kg m−2 in the oldest plant (8 years). Potential respiration was larger in the oldest plant (75 g O2 m−2 h−1) than in the most recent one (15 g O2 m−2 h−1). Accumulated matter seemed to play a role both on the water retention (enhancing initial percolation time by 5 times) and biological profile (enhancing microfauna's diversity). Contrary to what is generally proposed in the literature, accumulated matter in French gVFCWs seemed to provide better treatment efficiency without leading to surface clogging compared to systems using sand.