Chester L. Bowen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Chester L. Bowen has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Christopher A Evans
Bioanalytical Science & Toxicokinetics, DMPK, Platform Technology & Science, GlaxoSmithKline Pharmaceuticals, 709 Swedeland Road, King of Prussia, PA19406, USA
4 shared publicationsHermes Licea-Perez
Bioanalytical Science & Toxicokinetics, DMPK, Platform Technology & Science, GlaxoSmithKline Pharmaceuticals, 709 Swedeland Road, King of Prussia, PA19406, USA
4 shared publicationsJonathan Kehler
Bioanalytical Science & Toxicokinetics, DMPK, Platform Technology & Science, GlaxoSmithKline Pharmaceuticals, 709 Swedeland Road, King of Prussia, PA 19406, USA
2 shared publicationsAlan Stokes
Safety Assessment, Platform Technology & Science, GlaxoSmithKline Pharmaceuticals, NC27709, USA
1 shared publicationBonnie Orr
Bioanalytical Science and Toxicokinetics
1 shared publicationCarol Overvold
Platform Technology & Science, GlaxoSmithKline Pharmaceuticals, 709 Swedeland Road, King of Prussia, PA19406, USA
1 shared publication
Latest Publications
- 25 January 2016
- Published by Taylor & Francis in Bioanalysis
- Vol. 8 (3) , 205-214
Modify on The Fly: Triple Quad to High Resolution in Support of A Dermal Clinical Study Requiring an Ultra Low Lloq
Background: FTIH studies can be challenging due to the varying dosing regimens and rapid data delivery. Chemists are asked to provide ultra-low limits of quantitation to provide an understanding of patient efficacy and safety in order to progress drug development. In a recent dermal study it became necessary to reduce the LLOQ of a small molecule drug from 50 to 1 pg/ml due to reductions in the dose and surface area of drug application. Methodology: The 50-fold increase in assay sensitivity necessitated the use of a high-resolution mass spectrometer (LC–HRMS) to separate matrix interferences observed when using a unit resolution triple quadrupole MS. Conclusion: A sensitive, robust assay was validated to support of a FTIH study using a LC–HRMS.
- 25 January 2016
- Published by Taylor & Francis in Bioanalysis
- Vol. 8 (3) , 205-214
Modify on The Fly: Triple Quad to High Resolution in Support of A Dermal Clinical Study Requiring an Ultra Low Lloq
Background: FTIH studies can be challenging due to the varying dosing regimens and rapid data delivery. Chemists are asked to provide ultra-low limits of quantitation to provide an understanding of patient efficacy and safety in order to progress drug development. In a recent dermal study it became necessary to reduce the LLOQ of a small molecule drug from 50 to 1 pg/ml due to reductions in the dose and surface area of drug application. Methodology: The 50-fold increase in assay sensitivity necessitated the use of a high-resolution mass spectrometer (LC–HRMS) to separate matrix interferences observed when using a unit resolution triple quadrupole MS. Conclusion: A sensitive, robust assay was validated to support of a FTIH study using a LC–HRMS.
- 20 November 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (1) , 237-243
Utilizing LC-MS/MS to provide adaptable clinical bioanalytical support for an extended half-life bioactive peptide fused to an albumin-binding domain antibody
Bioactive peptides are often unstable in the body leading to short half lives and requiring frequent dosing intervals.
- 20 November 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (1) , 237-243
Utilizing LC-MS/MS to provide adaptable clinical bioanalytical support for an extended half-life bioactive peptide fused to an albumin-binding domain antibody
Bioactive peptides are often unstable in the body leading to short half lives and requiring frequent dosing intervals.
- 3 May 2013
- Published by Taylor & Francis in Bioanalysis
- Vol. 5 (9) , 1131-1135
A Novel Approach to Capillary Plasma Microsampling for Quantitative Bioanalysis
A novel device and procedure for the collection and isolation of microvolumes of plasma have been developed and two pilot rodent PK studies have been completed. This method involves collection of blood into a plastic-wrapped, EDTA-coated capillary tube, containing a small amount of a thixotropic gel and a porous plug. Following blood collection, the capillary is placed into a secondary labeled container suitable for centrifugation and plasma is generated. During centrifugation, the thixotropic gel isolates the plasma from the red blood cells and creates a physical barrier between the two matrices. The plasma is then dispensed from the capillary tube into a separate container for storage or processing. A simple and robust novel approach for the collection of small plasma volumes from rodent TK studies has been demonstrated.
- 3 May 2013
- Published by Taylor & Francis in Bioanalysis
- Vol. 5 (9) , 1131-1135
A Novel Approach to Capillary Plasma Microsampling for Quantitative Bioanalysis
A novel device and procedure for the collection and isolation of microvolumes of plasma have been developed and two pilot rodent PK studies have been completed. This method involves collection of blood into a plastic-wrapped, EDTA-coated capillary tube, containing a small amount of a thixotropic gel and a porous plug. Following blood collection, the capillary is placed into a secondary labeled container suitable for centrifugation and plasma is generated. During centrifugation, the thixotropic gel isolates the plasma from the red blood cells and creates a physical barrier between the two matrices. The plasma is then dispensed from the capillary tube into a separate container for storage or processing. A simple and robust novel approach for the collection of small plasma volumes from rodent TK studies has been demonstrated.
- 1 February 2013
- Published by Elsevier in Journal of Chromatography B
- Vol. 917-918, 24-29
Development of a sensitive and selective LC–MS/MS method for the determination of urea in human epithelial lining fluid
- 1 February 2013
- Published by Elsevier in Journal of Chromatography B
- Vol. 917-918, 24-29
Development of a sensitive and selective LC–MS/MS method for the determination of urea in human epithelial lining fluid
- 5 December 2012
- Published by Taylor & Francis in Bioanalysis
- Vol. 4 (23) , 2823-2832
Evaluation of Glucuronide Metabolite Stability in Dried Blood Spots
Stabilization of phase II metabolites is an important consideration during bioanalytical method development, method validation and sample analysis. Generic approaches to stabilize these metabolites during storage in liquid-based matrices include pH adjustment of samples prior to storage and/or temperature control; although a variety of other compound-specific stabilization techniques exist. Dried blood spot (DBS) technology is becoming a popular alternative to liquid matrix sampling in many preclinical and clinical applications. However, concerns remain regarding the stability of metabolites stored under ambient conditions using DBS. Experimental data have shown that, under ambient storage conditions, the stability of the glucuronides investigated herein stored as DBS is equivalent to that of liquid samples stored at -80°C. The decision to employ DBS technology for a given study needs to be considered on a case-by-case basis with an understanding of compound-specific metabolism characteristics and clinical study design.
- 5 December 2012
- Published by Taylor & Francis in Bioanalysis
- Vol. 4 (23) , 2823-2832
Evaluation of Glucuronide Metabolite Stability in Dried Blood Spots
Stabilization of phase II metabolites is an important consideration during bioanalytical method development, method validation and sample analysis. Generic approaches to stabilize these metabolites during storage in liquid-based matrices include pH adjustment of samples prior to storage and/or temperature control; although a variety of other compound-specific stabilization techniques exist. Dried blood spot (DBS) technology is becoming a popular alternative to liquid matrix sampling in many preclinical and clinical applications. However, concerns remain regarding the stability of metabolites stored under ambient conditions using DBS. Experimental data have shown that, under ambient storage conditions, the stability of the glucuronides investigated herein stored as DBS is equivalent to that of liquid samples stored at -80°C. The decision to employ DBS technology for a given study needs to be considered on a case-by-case basis with an understanding of compound-specific metabolism characteristics and clinical study design.
- 14 July 2011
- Published by Taylor & Francis in Bioanalysis
- Vol. 3 (14) , 1625-1633
Investigations into the Environmental Conditions Experienced During Ambient Sample Transport: Impact to Dried Blood Spot Sample Shipments
Background: Prior to bioanalysis, sample transport and storage are critical considerations in any pharmacokinetic or toxicokinetic study design. Care must be taken to ensure the shipment is properly packaged and tracked to make certain it arrives at the desired, final destination in the appropriate timeframe, and that the integrity of the sample is not compromised. When dealing with biological specimens, environmental conditions may have a deleterious effect on the stability and conditions of the sample. Results: Currently, frozen plasma or blood samples are the matrix of choice within the pharmaceutical industry for analysis within both preclinical and clinical trials. Liquid samples are shipped and received frozen and, therefore, the assumption is made that the frozen conditions are maintained throughout the entire transit process. Dried blood spot and dried matrix spot samples are becoming popular alternatives to plasma sampling in many small- and even large-molecule applications. With the implementati...
- 14 July 2011
- Published by Taylor & Francis in Bioanalysis
- Vol. 3 (14) , 1625-1633
Investigations into the Environmental Conditions Experienced During Ambient Sample Transport: Impact to Dried Blood Spot Sample Shipments
Background: Prior to bioanalysis, sample transport and storage are critical considerations in any pharmacokinetic or toxicokinetic study design. Care must be taken to ensure the shipment is properly packaged and tracked to make certain it arrives at the desired, final destination in the appropriate timeframe, and that the integrity of the sample is not compromised. When dealing with biological specimens, environmental conditions may have a deleterious effect on the stability and conditions of the sample. Results: Currently, frozen plasma or blood samples are the matrix of choice within the pharmaceutical industry for analysis within both preclinical and clinical trials. Liquid samples are shipped and received frozen and, therefore, the assumption is made that the frozen conditions are maintained throughout the entire transit process. Dried blood spot and dried matrix spot samples are becoming popular alternatives to plasma sampling in many small- and even large-molecule applications. With the implementati...
- 20 October 2010
- Published by Taylor & Francis in Bioanalysis
- Vol. 2 (11) , 1823-1828
Utility of Dried Blood Spot Sampling and Storage for Increased Stability of Photosensitive Compounds
Compound stability remains a major point of concern within pharmaceutical development. In attempts to minimize degradation, scientists may utilize acidification of samples prior to storage, dark chambers, decreased freezer temperatures and a variety of other stabilization techniques. All of these steps require additional procedures, increased costs and increased validation steps. Dried blood spots (DBS) are becoming a popular alternative to plasma sampling in many small- and even large-molecule applications. An investigation was performed in order to establish if DBS would provide storage advantages over liquid-based matrices for two light-sensitive compounds, nifedipine and omeprazole, to prevent or minimize photodegradation. Experimental data has shown, through forced and natural photodegradation experiments, that the compounds nifedipine and omeprazole exhibit increased photostability when spotted and stored on various DBS paper, when compared with water, plasma or whole blood. For omeprazole, between 40 and 90% loss was observed in liquid matrices, while photodegradation was negligible when utilizing DBS. Some loss of nifedipine is noted during exposure conditions on DBS; however, photodegradation in liquid matrices is far more severe. Within the experimental compound set, DBS technology offers a significant reduction in the photodegradation process when compared with the liquid matrices water, plasma or blood.
- 20 October 2010
- Published by Taylor & Francis in Bioanalysis
- Vol. 2 (11) , 1823-1828
Utility of Dried Blood Spot Sampling and Storage for Increased Stability of Photosensitive Compounds
Compound stability remains a major point of concern within pharmaceutical development. In attempts to minimize degradation, scientists may utilize acidification of samples prior to storage, dark chambers, decreased freezer temperatures and a variety of other stabilization techniques. All of these steps require additional procedures, increased costs and increased validation steps. Dried blood spots (DBS) are becoming a popular alternative to plasma sampling in many small- and even large-molecule applications. An investigation was performed in order to establish if DBS would provide storage advantages over liquid-based matrices for two light-sensitive compounds, nifedipine and omeprazole, to prevent or minimize photodegradation. Experimental data has shown, through forced and natural photodegradation experiments, that the compounds nifedipine and omeprazole exhibit increased photostability when spotted and stored on various DBS paper, when compared with water, plasma or whole blood. For omeprazole, between 40 and 90% loss was observed in liquid matrices, while photodegradation was negligible when utilizing DBS. Some loss of nifedipine is noted during exposure conditions on DBS; however, photodegradation in liquid matrices is far more severe. Within the experimental compound set, DBS technology offers a significant reduction in the photodegradation process when compared with the liquid matrices water, plasma or blood.
- 1 August 2010
- Published by Future Science Ltd in Bioanalysis
- Vol. 2 (8) , 1461-1468
Application of DBS for quantitative assessment of the peptide Exendin-4; comparison of plasma and DBS method by UHPLC–MS/MS
Background: An investigation was performed in order to establish if dried blood spots (DBS) could be applied to the quantitation of biopharmaceuticals in biological matrices and perform equivalently in terms of accuracy, precision and stability to traditional plasma methods. Results: A method was successfully validated for the peptide Exendin-4 (39 amino acids in length) utilizing DBS technology. The validated DBS method resulted in a more sensitive and simplistic method than an existing monkey plasma method and required tenfold less sample volume. The final DBS method resulted in a 10–2000-ng/ml linear calibration range using approximately 5 µl of dried blood, compared with the plasma method in which 150 µl of plasma coupled with SPE sample preparation resulted in a 20–2000-ng/ml linear calibration range. Although not needed for DBS, SPE was required for the plasma method to reduce endogenous matrix interferences and achieve desired LLOQ. Matrix stability was also enhanced by the implementation of the DBS platform when compared with either plasma or whole blood. Conclusion: DBS technology can be utilized for the quantitation of biopharmaceuticals and offer advantages over traditional plasma-based methods.
- 1 August 2010
- Published by Future Science Ltd in Bioanalysis
- Vol. 2 (8) , 1461-1468
Application of DBS for quantitative assessment of the peptide Exendin-4; comparison of plasma and DBS method by UHPLC–MS/MS
Background: An investigation was performed in order to establish if dried blood spots (DBS) could be applied to the quantitation of biopharmaceuticals in biological matrices and perform equivalently in terms of accuracy, precision and stability to traditional plasma methods. Results: A method was successfully validated for the peptide Exendin-4 (39 amino acids in length) utilizing DBS technology. The validated DBS method resulted in a more sensitive and simplistic method than an existing monkey plasma method and required tenfold less sample volume. The final DBS method resulted in a 10–2000-ng/ml linear calibration range using approximately 5 µl of dried blood, compared with the plasma method in which 150 µl of plasma coupled with SPE sample preparation resulted in a 20–2000-ng/ml linear calibration range. Although not needed for DBS, SPE was required for the plasma method to reduce endogenous matrix interferences and achieve desired LLOQ. Matrix stability was also enhanced by the implementation of the DBS platform when compared with either plasma or whole blood. Conclusion: DBS technology can be utilized for the quantitation of biopharmaceuticals and offer advantages over traditional plasma-based methods.
- 1 July 2009
- Published by Elsevier in Journal of Chromatography B
- Vol. 877 (22) , 2123-2129
Development of a sensitive and selective LC–MS/MS method for simultaneous determination of gemcitabine and 2,2-difluoro-2-deoxyuridine in human plasma
- 1 July 2009
- Published by Elsevier in Journal of Chromatography B
- Vol. 877 (22) , 2123-2129
Development of a sensitive and selective LC–MS/MS method for simultaneous determination of gemcitabine and 2,2-difluoro-2-deoxyuridine in human plasma