ATAndrew C.F. Taylor

Andrew C.F. Taylor

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrew C.F. Taylor has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Added value of narrow band imaging and confocal laser endomicroscopy in detecting Barrett's esophagus neoplasia

    by C. Jayasekera, A. C. F. Taylor, P. V. Desmond, F. Macrae, R. Williams

    Jayasekera C et al. Added value of narrow band imaging and confocal laser endomicroscopy in detecting Barrett’s esophagus neoplasia. Endoscopy 2012; 44: 1089–1095 Figure 2 in our article inadvertently included images not derived from the patients whose endoscopic images are depicted. The images included were used as illustrative only of the pathology. We apologize for this and to the authors of the images that were included (Ralf Kiesslich and Mimi Canto) The confocal images herewith are from these two patients demonstrating intramucosal carcinoma and high grade dysplasia. The new images depicted for the purposes of publication do not alter the data as published. We would also like to acknowledge the collaborative assistance of Mr Peter Delaney. Drs Chatura Jayasekera, Andrew Taylor, Paul Desmond, Finlay Macrae and Richard Williams.


  • Gastroesophageal Reflux and Related Pathology in Adults Who Were Born With Esophageal Atresia: A Long-Term Follow-up Study

    by Andrew C.F. Taylor, Kerry J. Breen, Alex Auldist, Anthony Catto–Smith, Tom Clarnette, Joe Crameri, Russell Taylor, Satish Nagarajah, Jocelyn Brady, Keith Stokes


  • Prospective Assessment of the Diagnostic and Therapeutic Impact of Small-Bowel Push Enteroscopy

    by A. C. F. Taylor, R. J. Buttigieg, I. G. McDonald, P. V. Desmond

    Background and Study Aims: Although the reported diagnostic yield of push enteroscopy has been substantial in previous studies, its clinical impact has never been prospectively evaluated. The primary aim of this study was to prospectively determine the diagnostic and therapeutic impact of enteroscopy. In addition, the yield of new and clinically important findings was prospectively assessed. Patients and Methods: Consecutive patients referred for enteroscopy were studied. The referring clinician completed a form indicating the working diagnosis, degree of diagnostic certainty, and the management plan had enteroscopy been unavailable. Diagnostic certainty was indicated on a scale of 1 = very unlikely (1 - 9 %) to 6 = certain (100 %). Following enteroscopy, the referring doctor completed another form indicating these features in the light of the enteroscopic findings. Results: The study group comprised 77 patients referred for 79 push enteroscopies. There was a change in working diagnosis or management plan as a result of enteroscopy in 39/77 (51 %) patients. The working diagnosis and the management plan changed in 29/77 (38 %) and 34/77 (44 %), respectively, and the diagnostic certainty changed in a further 29 patients (38 %). There were clinically significant small-bowel findings in 16 (20 %) and new upper gastrointestinal findings in 16 (20 %), giving an overall diagnostic yield of 40 %. Conclusions: Enteroscopy has a significant impact on clinicians’ working diagnoses and management plans.


  • Reply to Bureš & Rejchrt

    by A. C. F. Taylor, R. Y. M. Chen, P. V. Desmond

    Dear Sir, We thank Drs Bureš and Rejchrt for their comments on our paper. We agree that optimal positioning of the overtube is not always straightforward and that the overtube tip does not always lie in the ideal position in the duodenum. Their comments on the x-ray images shown in our article are understandable, but we do not believe their interpretation is correct. Interpretation of the x-ray images is somewhat difficult because of the position of the patient. Although the caption states that the patient is in the left lateral position, it can be seen that the patient has rolled forward somewhat, as the spine is not the most lateral point on the image. Nevertheless, the position is mainly lateral, so the loop of the duodenum passes posteriorly from the stomach and then superiorly and anteriorly to the duodenojejunal flexure. Hence, the arrows indicating the tip of the overtube in the proximal duodenum and the duodenojejunal flexure are correct.

  • Use of an Overtube for Enteroscopy - Does it Increase Depth of Insertion? A Prospective Study of Enteroscopy with and without an Overtube

    by A. C. Taylor, R. Y. Chen, P. V. Desmond

    Background and Study Aims: Although a stiffening overtube is commonly used with push enteroscopy, in the belief that this will allow increased insertion into the small intestine, there is no prospective data to support this view. The aim of this study is to prospectively study the depth of insertion into the small intestine at enteroscopy with and without an overtube. Patients and Methods: A total of 38 patients referred for enteroscopy were prospectively studied. Alternate enteroscopies were performed with or without an overtube; therefore 19 patients had enteroscopy with and 19 without an overtube. The groups were well matched for age, sex, indication, use of fluoroscopy, and dedicated anesthetic assistance. Depth of insertion was assessed by advancing the enteroscope as far as possible, then straightening the enteroscope until the tip began withdrawing. The difference between the straightened insertion depth and the distance from the incisors to the pylorus was recorded as the insertion depth beyond the pylorus. This was considered the major end point. Statistical analysis was performed using the Mann-Whitney test for nonparametric data. Results: The median straightened total insertion depth from the incisors was greater when enteroscopy was performed with an overtube compared with enteroscopy without an overtube (125 cm vs. 110 cm, P = 0.05). The median straightened insertion depth beyond the pylorus was significantly greater with overtube use (70 cm vs. 50 cm, P = 0.01). No significant difference between the groups was observed in terms of the likelihood of significant findings at enteroscopy. Conclusions: Use of an overtube for push enteroscopy results in significantly deeper insertion into the small intestine. Although a larger study would be needed to demonstrate an increase in diagnostic yield and to confirm the safety of overtube use, this study does provide the first objective evidence of an advantage in terms of insertion depth.