RMRejean Munger

Rejean Munger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rejean Munger has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Quantitative impact of small angle forward scatter on whole blood oximetry using a Beer–Lambert absorbance model

    by Serge Emile LeBlanc, Monica Atanya, Kevin Burns, Rejean Munger

    It is well known that red blood cell scattering has an impact on whole blood oximetry as well as in vivoretinal oxygen saturation measurements. The goal of this study was to quantify the impact of small angle forward scatter on whole blood oximetry for scattering angles found in retinal oximetry light paths. Transmittance spectra of whole blood were measured in two different experimental setups: one that included small angle scatter in the transmitted signal and one that measured the transmitted signal only, at absorbance path lengths of 25, 50, 100, 250 and 500 µm. Oxygen saturation was determined by multiple linear regression in the 520–600 nm wavelength range and compared between path lengths and experimental setups. Mean calculated oxygen saturation differences between setups were greater than 10% at every absorbance path length. The deviations to the Beer–Lambert absorbance model had different spectral dependences between experimental setups, with the highest deviations found in the 520–540 nm range when scatter was added to the transmitted signal. These results are consistent with other models of forward scatter that predict different spectral dependences of the red blood cell scattering cross-section and haemoglobin extinction coefficients in this wavelength range.


  • Innervation of Tissue-Engineered Recombinant Human Collagen-Based Corneal Substitutes: A Comparative In Vivo Confocal Microscopy Study

    by Neil Lagali, May Griffith, Per Fagerholm, Kimberley Merrett, Melissa Huynh, Rejean Munger

    Purpose. To compare reinnervation in recombinant human collagen-based corneal substitutes with allografts during a 1-year postimplantation follow-up period in pigs. A retrospective comparison to innervation in porcine collagen-based biosynthetic grafts was also performed. methods. Pigs received a corneal allograft or a substitute made of either recombinant human type-I or -III collagen. In vivo confocal microscopic examination of the central cornea of surgical and untouched control eyes before surgery and at 2, 6, and 12 months after surgery was performed to quantify the number, density, and diameter of nerves at various corneal depths. results. By 12 months after surgery, the number and density of regenerated nerves in the anterior and deep anterior corneal stroma recovered to preoperative and control levels in both types of substitute grafts and in the allografts. In the subepithelial and subbasal regions, however, significantly fewer nerves were detected relative to those in control subjects at 12 months, regardless of graft type (P < 0.05), similar to the behavior of porcine collagen-based biosynthetic grafts. An absence of thick stromal nerve trunks (diameter, >10 μm) in all grafts, irrespective of material type, indicated that nerve regeneration in grafts was accompanied by persistent morphologic changes. conclusions. Nerve regeneration in recombinant human collagen-based biosynthetic corneal grafts proceeded similarly to that in allograft tissue, demonstrating the suitability of recombinant human collagen constructs as nerve-friendly corneal substitutes. Furthermore, only minor differences were noted between type-I and -III collagen grafts, indicating an insensitivity of nerve regeneration to initial collagen type.


  • Changes in measured intraocular pressure after hyperopic photorefractive keratectomy

    by Rejean Munger, Ali A Dohadwala, William G Hodge, Bruce W. Jackson, George Mintsioulis, Karim F Damji

    To investigate the effect of hyperopic photorefractive keratectomy (PRK) on intraocular pressure (IOP) measurements. University of Ottawa Eye Institute, Ottawa Hospital, Ottawa, Canada. In this retrospective cohort study, IOP and central corneal thickness (CCT) were measured preoperatively and at 1, 2, 3, 6, 12, 18, and 24 months in 191 eyes that had hyperopic PRK with the VISX Star excimer laser. All corrections applied were between +1.00 and +6.50 diopters (D) of sphere and less than 3.75 D of cylinder. At all postoperative examinations, the mean IOP in the hyperopic PRK group was 1.0 to 1.8 mm Hg lower than the preoperative IOP (P <.001). A large range of IOP changes was found across the population; eg, at 6 months, 49% of the eyes had a change in IOP from baseline of at least +/-3 mm Hg. A mean reduction of 19 microm of CCT was found with pachymetry after surgery (P < .001). The change in IOP readings postoperatively was not correlated with age, sex, keratometric readings, or applied correction. Changes in IOP were strongly correlated with preoperative IOP at all time points and with preoperative CCT at 18 and 24 months (P < .001). After hyperopic PRK, the measured IOP was more likely to increase in patients with preoperative IOPs less than 14.5 mm Hg and more likely to decrease in patients with preoperative IOPs above 14.5 mm Hg. Changes in IOP after hyperopic PRK were similar to changes after myopic PRK, despite only minimal changes in the CCT. This suggests that hyperopic PRK results in biomechanical effects that modify the elastic properties of the cornea beyond the changes in rigidity expected from central corneal thinning. There was a strong negative correlation between the measured preoperative IOP and the change in IOP postoperatively that was likely the result of regression of the mean effect.


    • 1 April 1998
      • Vol. 33  (3) , 159-65

    Correction of intraocular pressure for changes in central corneal thickness following photorefractive keratectomy.

    by R Munger, W G Hodge, G Mintsioulis, P J Agapitos, W B Jackson, K F Damji

    To investigate the relation between measurements of intraocular pressure (IOP) and central corneal thickness (CCT) in myopic patients undergoing photorefractive keratectomy (PRK). Descriptive study. University-affiliated eye care centre in Ottawa. A total of 481 consecutive eyes of 318 patients with a mean preoperative refractive error of -6.50 dioptres treated with excimer PRK between March 1993 and December 1996. IOP measured by Goldmann applanation tonometry and CCT before and 3, 6, 12, 18 and 24 months after surgery. CCT was a significant predictor of IOP only before PRK and 6 months after PRK (p < or = 0.05). The relation between IOP and CCT suggests corrections for CCT that are not clinically significant (0.81 mm Hg [standard error (SE) 0.33 mm Hg] and 1.00 mm Hg [SE 0.38 mm Hg] per 100 microns of corneal thinning preoperatively and at 6 months respectively). On average, there was a significant decrease in IOP after PRK (0.96 mm Hg and 1.24 mm Hg at 12 and 24 months respectively) (p < 0.05). There was a significant correlation between change in IOP and change in CCT (decrease of 2.1 mm Hg per 100 microns of corneal thinning) (p < 0.05). For a given change in CCT, individual changes in IOP were variable, with increases or decreases of more than 5 mm Hg in some cases. There are individual differences in IOP changes following PRK. Until further data are available we propose that the change in IOP between the preoperative visit (or the fellow eye, if healthy or untreated) and the 12-month visit be used as an individual correction factor to be applied to IOP measurements in the operated eye.