Taisuke Masuda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Taisuke Masuda has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Fumihito Arai
Nagoya University
13 shared publications- Hisataka Maruyama
Nagoya University
6 shared publications Hayao Nakanishi
Aichi Science and Technology Foundation
2 shared publications- Hirofumi Owaki
Nagoya University
2 shared publications Miyako Niimi
Nagoya University
2 shared publicationsNatsuki Takei
Nagoya University
2 shared publications
Latest Publications
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 1G02
Micro environmental sensor for biological tissue measurement
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 1G02
Micro environmental sensor for biological tissue measurement
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2017, 2P2-L01
Function Control of Optically-Driven Fluorescence Sensor with Multiple Wavelength Lights
Control of function of a specific microsensor has a potential for single cell analysis with micro-nano robotic approach. We propose a new method of optical function control of the fluorescence microsensors such as manipulation, measurement, zeta potential control, and local heating using surface plasmon resonance with multiple wavelength lights. The microsensor is fabricated by modification of a fluorescence polystyrene microbead by gold nanorod and encapsulating the modified microbead into a lipid layer with 1,3,3-trimethylindolino-6'–nitrobenzopyrylospiran (SP), which is a photochromic material. This fluorescence microsensor is manipulated by optical tweezers with 1064 nm laser. Measurement of local environment is measured using fluorescence indicator in the microsensor. The zeta potential of the fluorescence microsensor switches from negative to positive by photo-isomerization of SP with ultraviolet irradiation. The fluorescence microsensor is heated by surface plasmon resonance with 808 nm laser. As demonstrations, each function of fluorescence microsensor was confirmed with multiple wavelength lights.
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2017, 2P2-L01
Function Control of Optically-Driven Fluorescence Sensor with Multiple Wavelength Lights
Control of function of a specific microsensor has a potential for single cell analysis with micro-nano robotic approach. We propose a new method of optical function control of the fluorescence microsensors such as manipulation, measurement, zeta potential control, and local heating using surface plasmon resonance with multiple wavelength lights. The microsensor is fabricated by modification of a fluorescence polystyrene microbead by gold nanorod and encapsulating the modified microbead into a lipid layer with 1,3,3-trimethylindolino-6'–nitrobenzopyrylospiran (SP), which is a photochromic material. This fluorescence microsensor is manipulated by optical tweezers with 1064 nm laser. Measurement of local environment is measured using fluorescence indicator in the microsensor. The zeta potential of the fluorescence microsensor switches from negative to positive by photo-isomerization of SP with ultraviolet irradiation. The fluorescence microsensor is heated by surface plasmon resonance with 808 nm laser. As demonstrations, each function of fluorescence microsensor was confirmed with multiple wavelength lights.
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2017, 2A1-N10
Bionic Humanoid: Biomimetic Retina Model Having Photoelastic Stress Sensor
We proposed sensor-integrated retina model with similar Young's modulus to human retina for training of ophthalmologist. Mimic of mechanical properties of human retina is important issue for surgical simulator. Moreover, integrated of sensor into model is useful for evaluation of surgeon skill. First, we fabricate eye ball model having retina and scleral with similar Young's modulus to human by adjusting the concentration of catalyst. Then, photoelastic coefficient of retinal model is increased by adding the carbon nanomaterial. As a demonstration, stress distribution on retinal model was measured using the assembled retina and sclera model in skull model having polarization optical system.
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2017, 2A1-N10
Bionic Humanoid: Biomimetic Retina Model Having Photoelastic Stress Sensor
We proposed sensor-integrated retina model with similar Young's modulus to human retina for training of ophthalmologist. Mimic of mechanical properties of human retina is important issue for surgical simulator. Moreover, integrated of sensor into model is useful for evaluation of surgeon skill. First, we fabricate eye ball model having retina and scleral with similar Young's modulus to human by adjusting the concentration of catalyst. Then, photoelastic coefficient of retinal model is increased by adding the carbon nanomaterial. As a demonstration, stress distribution on retinal model was measured using the assembled retina and sclera model in skull model having polarization optical system.
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2016, 2P1-19a5
Laser-Assist Rapid Injection of Nano sensor into Cell
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2016, 2P1-19a5
Laser-Assist Rapid Injection of Nano sensor into Cell
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2015, _1P1-L05_1
1P1-L05 Automated rare cell isolation and pick-up using air-liquid interface control on open-chip
For molecular analysis of the rare cells, such as Circulating Tumor Cells (CTCs), the single rare cell isolation from the suspension which contains large population of other cells is required. Here, we propose a platform which utilizes surface tension and suction force to array single cells on the microfluidic chip with open channels. Cells flowed to the meniscus of air/liquid interface due to the suction force caused by a suction pump. Then, through surface tension which was generated by the air-liquid interface, the cells were deposited and trapped in the specified pockets surrounded with micropillars. Previously we already succeeded in isolating the rare cell with high speed. We developed a system for cell isolation and pick-up. We purpose to control the position of the air-liquid interface balancing supply and suction pumps. The experiment was performed with human gastric carcinoma cell line (GCIY) cells experiments. By using our isolation methods, the trap rates of cells were nearly 90 %. Also, we utilized mouse CTC model to demonstrate clinical utility of our method. Our platform will be useful for single rare cell analysis because the collected cells could be picked up by glass micro pipette rapidly and easily.
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2015, _1P1-L05_1
1P1-L05 Automated rare cell isolation and pick-up using air-liquid interface control on open-chip
For molecular analysis of the rare cells, such as Circulating Tumor Cells (CTCs), the single rare cell isolation from the suspension which contains large population of other cells is required. Here, we propose a platform which utilizes surface tension and suction force to array single cells on the microfluidic chip with open channels. Cells flowed to the meniscus of air/liquid interface due to the suction force caused by a suction pump. Then, through surface tension which was generated by the air-liquid interface, the cells were deposited and trapped in the specified pockets surrounded with micropillars. Previously we already succeeded in isolating the rare cell with high speed. We developed a system for cell isolation and pick-up. We purpose to control the position of the air-liquid interface balancing supply and suction pumps. The experiment was performed with human gastric carcinoma cell line (GCIY) cells experiments. By using our isolation methods, the trap rates of cells were nearly 90 %. Also, we utilized mouse CTC model to demonstrate clinical utility of our method. Our platform will be useful for single rare cell analysis because the collected cells could be picked up by glass micro pipette rapidly and easily.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2013, _1A1-O07_1
1A1-O07 Selective Injection of Single Nano-Particle Sensor Using Optical Surface-Potential Control for Intracellular Temperature Measurement(Nano/Micro Manipulation System)
We developed selective injection of a single particle sensor using optically-regulated cell adhesion and injection for intracellular temperature measurement. Fluorescence sensor encapsulated in liposome is fabricated by spontaneous transfer method. The liposome is consists of neural lipids and spiropyran (SP). SP is a photochromic material and used for optical surface potential control of the liposome. The liposome adheres to the cell membrane by coulomb's force under UV illumination. The sensor can contain various fluorescence indicators such as Rhodmaine B as temperature sensor. The liposome encapsulating the sensor is contacted to the cell membrane using optical tweezers. We evaluated encapsulation efficiency of the sensor into the liposome and adhesion efficiency to cell membrane. We demonstrated the optically-controlled adhesion of the sensor to MDCK cell and observed the injected sensor by laser confocal fluorescence method. As results, we succeeded in injection of particle sensor into the cell cytoplasm and nucleus.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2013, _1A1-O07_1
1A1-O07 Selective Injection of Single Nano-Particle Sensor Using Optical Surface-Potential Control for Intracellular Temperature Measurement(Nano/Micro Manipulation System)
We developed selective injection of a single particle sensor using optically-regulated cell adhesion and injection for intracellular temperature measurement. Fluorescence sensor encapsulated in liposome is fabricated by spontaneous transfer method. The liposome is consists of neural lipids and spiropyran (SP). SP is a photochromic material and used for optical surface potential control of the liposome. The liposome adheres to the cell membrane by coulomb's force under UV illumination. The sensor can contain various fluorescence indicators such as Rhodmaine B as temperature sensor. The liposome encapsulating the sensor is contacted to the cell membrane using optical tweezers. We evaluated encapsulation efficiency of the sensor into the liposome and adhesion efficiency to cell membrane. We demonstrated the optically-controlled adhesion of the sensor to MDCK cell and observed the injected sensor by laser confocal fluorescence method. As results, we succeeded in injection of particle sensor into the cell cytoplasm and nucleus.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2013, _1P1-D07_1
1P1-D07 Culture and Evaluation System for Three-Dimensional Assembled Multilayered Tissues(Bio Assembler for 3D Cellular System Innovation)
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2013, _1P1-D07_1
1P1-D07 Culture and Evaluation System for Three-Dimensional Assembled Multilayered Tissues(Bio Assembler for 3D Cellular System Innovation)
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2013.25, 383-384
2D18 Virus Detection Chip by using On-Chip Chromatography
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2013.25, 383-384
2D18 Virus Detection Chip by using On-Chip Chromatography
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2012, _1A2-V03_1
1A2-V03 Injection of Single Fluorescent Microsensor into a Specific Cell Using Cell Membrane Fusion for Cellular Temperature Measurement(Nano/Micro Manipulation System)
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2012, _1A2-V03_1
1A2-V03 Injection of Single Fluorescent Microsensor into a Specific Cell Using Cell Membrane Fusion for Cellular Temperature Measurement(Nano/Micro Manipulation System)